Comparative performance of urinary creatinine excretion estimating equations

被引:0
作者
Huidobro, Juan Pablo E. [1 ,2 ]
Vega, Jorge [2 ,3 ]
Sepulveda, Rodrigo A. [1 ]
Astorga, Andres [4 ]
机构
[1] Pontificia Univ Catolica Chile, Fac Med, Escuela Med, Dept Nefrol, Santiago, Chile
[2] Hosp Naval Almirante Nef, Secc Nefrol, Vina Del Mar, Chile
[3] Univ Valparaiso, Dept Med, Valparaiso, Chile
[4] Hosp Dr Gustavo Fricke, Serv Med Interna, Vina Del Mar, Chile
关键词
Creatinine; Glomerular Filtration Rate; Kidney Function Tests; Renal Elimination; POTASSIUM EXCRETION; CLEARANCE; SODIUM; RACE;
D O I
暂无
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: 24-hour urine collection accuracy is generally evaluated based on the values of urine creatinine (UCr) excretion, usually using ranges adjusted by weight. UCr excretion depends on several factors. Equations to estimate UCr in 24-hour collection (UCr/24h) that consider these factors have been developed. However, these formulas have not been evaluated in a sample of Latinamerican origin. Aim: To evaluate the performance of the existing UCr/24 h estimation equations in a sample of Latinamerican origin. Material and Methods: 24-hour urine collections from 181 ambulatory patients were analyzed. Measured UCr/24h was compared with estimated UCr (eUCr) through the equations of Ix (CKD-EPI), Gerber-Mann, Goldwasser, Cockcroft-Gault, Rule, Walser, Kawasaki, Tanaka and Huidobro. Performance of the nine equations to estimate UCr/24h was evaluated with the Pearson correlation and Lin concordance coefficients, and Bland-Altman method. Bias, precision, and accuracy (percentage of collections within 30% of measured UCr or P30) were also calculated. Results: Measured UCr/24h in the 181 patients was 1236 + 378 mg. Correlation coefficient (Pearson) of the eUCr/24h with the equations of Walser, Ix and Huidobro and the measured UCr/24h was strongly positive. Rule and Kawasaki equations had the lowest positive correlation coefficients. Bias was similar using the formulas of Walser, Goldwasser, Kawasaki, Ix and Huidobro. Walser, Ix, Huidobro, Cockcroft-Gault and Goldwasser equations had good accuracy (P30 > 85%), while Gerber-Mann, Tanaka, Rule and Kawasaki formulas had a P30 < 65%. Conclusions: Walser, Ix and Huidobro equations had the best performance to estimate UCr/24h excretion in a population of latinamerican origin.
引用
收藏
页码:1561 / 1568
页数:8
相关论文
共 50 条
[21]   Normalisation of urinary biomarkers to creatinine for clinical practice and research - when and why [J].
Tang, Kai Wen Aaron ;
Toh, Qi Chun ;
Teo, Boon Wee .
SINGAPORE MEDICAL JOURNAL, 2015, 56 (01) :7-10
[22]   Performance of creatinine and cystatin C-based glomerular filtration rate estimating equations in a European HIV-positive cohort [J].
Gagneux-Brunon, Amandine ;
Delanaye, Pierre ;
Maillard, Nicolas ;
Fresard, Anne ;
Basset, Thierry ;
Alamartine, Eric ;
Lucht, Frederic ;
Pottel, Hans ;
Mariat, Christophe .
AIDS, 2013, 27 (10) :1573-1581
[23]   Anthropometry-based 24-h urinary creatinine excretion reference for Chinese children [J].
Wang, Wei ;
Du, Cong ;
Lin, Laixiang ;
Chen, Wen ;
Tan, Long ;
Shen, Jun ;
Pearce, Elizabeth N. ;
Zhang, Yixin ;
Gao, Min ;
Bian, Jianchao ;
Wang, Xiaoming ;
Zhang, Wanqi .
PLOS ONE, 2018, 13 (05)
[24]   Time courses of urinary creatinine excretion, measured creatinine clearance and estimated glomerular filtration rate over 30 days of ICU admission [J].
Volbeda, M. ;
Hessels, L. ;
Posma, R. A. ;
Bakker, S. J. ;
Nijsten, M. W. .
JOURNAL OF CRITICAL CARE, 2021, 63 :161-166
[25]   Decrease in Urinary Creatinine Excretion in Early Stage Chronic Kidney Disease [J].
Tynkevich, Elena ;
Flamant, Martin ;
Haymann, Jean-Philippe ;
Metzger, Marie ;
Thervet, Eric ;
Boffa, Jean-Jacques ;
Vrtovsnik, Francois ;
Houillier, Pascal ;
Froissart, Marc ;
Stengel, Benedicte .
PLOS ONE, 2014, 9 (11)
[26]   Urinary creatinine excretion, measured glomerular filtration rate and CKD outcomes [J].
Tynkevich, Elena ;
Flamant, Martin ;
Haymann, Jean-Philippe ;
Metzger, Marie ;
Thervet, Eric ;
Boffa, Jean-Jacques ;
Vrtovsnik, Francois ;
Houillier, Pascal ;
Froissart, Marc ;
Stengel, Benedicte .
NEPHROLOGY DIALYSIS TRANSPLANTATION, 2015, 30 (08) :1386-1394
[27]   Validation of the equations for estimating daily sodium excretion from spot urine in patients with chronic kidney disease [J].
Imai, Enyu ;
Yasuda, Yoshinari ;
Horio, Masaru ;
Shibata, Kanako ;
Kato, Sawako ;
Mizutani, Yu ;
Imai, Junko ;
Hayashi, Mutsuharu ;
Kamiya, Hideki ;
Oiso, Yutaka ;
Murohara, Toyoaki ;
Maruyama, Shoichi ;
Matsuo, Seiichi .
CLINICAL AND EXPERIMENTAL NEPHROLOGY, 2011, 15 (06) :861-867
[28]   Accuracy of the New Creatinine-based Equations for Estimating Glomerular Filtration Rate in Koreans [J].
Jeong, Tae-Dong ;
Hong, Jinyoung ;
Lee, Woochang ;
Chun, Sail ;
Min, Won-Ki .
ANNALS OF LABORATORY MEDICINE, 2023, 43 (03) :244-252
[29]   Diabetes influences the performance of creatinine-based equations for estimating glomerular filtration rate in the elderly population [J].
Jiao, Yuanyuan ;
Jiang, Shimin ;
Zhou, Jiahui ;
Zhang, Danyang ;
Li, Wenge .
EUROPEAN JOURNAL OF INTERNAL MEDICINE, 2022, 100 :146-148
[30]   Performance of Creatinine and Cystatin-Based Equations on Estimating Measured GFR in People with Hematological and Solid Cancers [J].
Titan, Silvia M. ;
Lieske, John C. ;
Meeusen, Jeffrey W. ;
Thorson, Stacy ;
Lin, Yi ;
Nowakowski, Grzegorz S. ;
Barreto, Jason N. ;
Barreto, Erin F. ;
Ruddy, Kathryn J. ;
Leung, Nelson ;
Rule, Andrew D. ;
Herrmann, Sandra M. .
CLINICAL JOURNAL OF THE AMERICAN SOCIETY OF NEPHROLOGY, 2025, 20 (03) :358-366