Static and Dynamic Cumulative Maximum Intensity Display Mode for Subharmonic Breast Imaging A Comparative Study With Mammographic and Conventional Ultrasound Techniques

被引:22
作者
Dave, Jaydev K. [3 ]
Forsberg, Flemming [1 ]
Fernandes, Savitha [3 ]
Piccoli, Catherine W. [4 ]
Fox, Traci B. [2 ]
Merton, Daniel A.
Leodore, Lauren M. [3 ]
Hall, Anne L. [5 ]
机构
[1] Thomas Jefferson Univ, Dept Radiol, Div Ultrasound, Philadelphia, PA 19107 USA
[2] Thomas Jefferson Univ, Dept Radiol Sci, Jefferson Sch Hlth Profess, Philadelphia, PA 19107 USA
[3] Drexel Univ, Sch Biomed Engn Sci & Hlth Syst, Philadelphia, PA 19104 USA
[4] S Jersey Radiol Associates, Voorhees, NJ USA
[5] GE Healthcare, Milwaukee, WI USA
关键词
breast ultrasound; cumulative maximum intensity; dynamic imaging; image processing; motion compensation; subharmonic imaging; INTRAVASCULAR ULTRASOUND; TUMOR ANGIOGENESIS; CONTRAST; LESIONS; CANCER; US; ARCHITECTURE; CARCINOMA;
D O I
10.7863/jum.2010.29.8.1177
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
Objective. The purpose of this study was to test the efficacy of static and dynamic cumulative maximum intensity (CMI) subharmonic imaging (SHI) in breast ultrasound studies. Methods. Contrast-enhanced SHI was performed in 14 women using a modified LOGIQ 9 scanner (GE Healthcare, Milwaukee, WI) transmitting/receiving at 4.4/2.2 MHz. Following mammography, baseline scans of gray scale ultrasound and power Doppler imaging (PDI) were performed. Contrast-enhanced PDI and gray scale SHI were performed after contrast agent administration. Static CMI-SHI is a composite image summarizing blood flow over multiple frames using the maximum intensity projection technique. The dynamic CMI-SHI mode depicts the gradual inflow pattern of the contrast agent in blood vessels. Both CMI-SHI modes were set up using a new automated sum-absolute-difference-based block-matching algorithm to reduce noise and blurring and compensate for motion artifacts. Evaluation of the imaging modes for detecting breast cancer was done by an experienced radiologist, blinded to histopathologic findings. Sensitivity, specificity, and receiver operating characteristic (ROC) analyses were computed and compared for all ultrasound imaging modes and mammography. Results. Of the 16 lesions, 4 were malignant. The area under the ROC curve (A,) for the diagnosis of breast cancer was 0.64 for gray scale and PDI, 0.67 for contrast-enhanced PDI, 0.76 for mammography, 0.78 for SHI, and 0.75 for static CMI-SHI. For the dynamic CMI-SHI mode, the A, increased to 0.90, and this was significantly better than mammography (P = .03). Conclusions. The new dynamic CMI-SHI mode produced the highest A, for the diagnosis of breast cancer compared to conventional techniques and thus appears to improve diagnosis of breast cancer relative to conventional techniques, albeit based on a limited patient population.
引用
收藏
页码:1177 / 1185
页数:9
相关论文
共 35 条
[1]  
[Anonymous], 2001, Ultrasound Contrast Agents: Basic Principles and Clinical Applications
[2]  
[Anonymous], 2009, United States cancer statistics: 1999-2005 incidence and mortality Web-based report
[3]  
Averkiou Michalakis, 2003, Ultrasound Q, V19, P27, DOI 10.1097/00013644-200303000-00004
[4]   Screening for Breast Cancer: US Preventive Services Task Force Recommendation Statement [J].
Calonge, Ned ;
Petitti, Diana B. ;
DeWitt, Thomas G. ;
Dietrich, Allen J. ;
Gregory, Kimberly D. ;
Grossman, David ;
Isham, George ;
LeFevre, Michael L. ;
Leipzig, Rosanne M. ;
Marion, Lucy N. ;
Melnyk, Bernadette ;
Moyer, Virginia A. ;
Ockene, Judith K. ;
Sawaya, George F. ;
Schwartz, J. Sanford ;
Wilt, Timothy .
ANNALS OF INTERNAL MEDICINE, 2009, 151 (10) :716-W236
[5]   Nondestructive subharmonic imaging [J].
Chomas, J ;
Dayton, P ;
May, D ;
Ferrara, K .
IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2002, 49 (07) :883-892
[6]   Ultrasound contrast agents:: properties, principles of action, tolerance, and artifacts [J].
Correas, JM ;
Bridal, L ;
Lesavre, A ;
Méjean, A ;
Claudon, M ;
Hélénon, O .
EUROPEAN RADIOLOGY, 2001, 11 (08) :1316-1328
[7]   Breast cancer as a global health concern [J].
Coughlin, Steven S. ;
Ekwueme, Donatus U. .
CANCER EPIDEMIOLOGY, 2009, 33 (05) :315-318
[8]   Image Processing Algorithms for Cumulative Maximum Intensity Subharmonic Ultrasound Imaging: A Comparative Study in the Breast [J].
Dave, Jaydev ;
Forsberg, Flemming ;
Merton, Daniel A. ;
Fernandes, Savitha ;
Fox, Traci B. ;
Leodore, Lauren M. ;
Hall, Anne L. .
2008 IEEE ULTRASONICS SYMPOSIUM, VOLS 1-4 AND APPENDIX, 2008, :1655-+
[9]   NOVEL AUTOMATED MOTION COMPENSATION TECHNIQUE FOR PRODUCING CUMULATIVE MAXIMUM INTENSITY SUBHARMONIC IMAGES [J].
Dave, Jaydev K. ;
Forsberg, Flemming .
ULTRASOUND IN MEDICINE AND BIOLOGY, 2009, 35 (09) :1555-1563
[10]   Microvascular architecture of breast lesions - Evaluation with contrast-enhanced ultrasonographic micro flow imaging [J].
Du, Jing ;
Li, Feng-Hua ;
Fang, Hua ;
Xia, Jian-Guo ;
Zhu, Cai-Xia .
JOURNAL OF ULTRASOUND IN MEDICINE, 2008, 27 (06) :833-842