The ground fault detection system for the Tore Supra toroidal pump limiter

被引:1
作者
Zunino, K
Cara, P
Fejoz, P
Hourtoule, J
Loarer, T
Pomaro, N
Santagiustina, A
Spuig, P
Villecrozea, F
机构
[1] CEA, EURATOM Assoc, DRFC, DSM, F-13108 St Paul Les Durance, France
[2] EURATOM, ENEA Fus, Consorzio RFX, I-35127 Padua, Italy
关键词
ground fault; Tore Supra; toroidal pump limiter;
D O I
10.1016/S0920-3796(03)00253-9
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
The toroidal pump limiter (TPL) of Tore Supra is electrically insulated from the vacuum-vessel, to allow its polarization at a voltage of up to 1 kV In order to monitor continuously the integrity of the TPL electrical insulation, an electronic diagnostic system called TPL ground fault detection system (GFDS) has been developed. The paper will report on the design and the operation experience of the GFD system and on the evolution of the TPL grounding. (C) 2003 Elsevier B.V. All rights reserved.
引用
收藏
页码:1019 / 1023
页数:5
相关论文
共 5 条
[1]   The ground loops detection system in the RFX machine [J].
Bellina, F ;
Pomaro, N ;
Trevisan, F .
FUSION TECHNOLOGY, 1996, 30 (03) :1217-1221
[2]  
*EUR CEA CIEL PROJ, 6983 CCFP EUR CEA CI
[3]  
LEHNEN M, 2002, C PLASM SURF INT JAP
[4]  
POMARO N, 1998, P 21 S FUS TECHN MAR, V1, P701
[5]  
SANTAGIUSTINA A, 2001, NTT2001004 POLO