Comparison of polymerization shrinkage of a new bulk-fill flowable composite with other composites: An in vitro study

被引:15
作者
Tusi, Somayeh Khoramian [1 ]
Hamdollahpoor, Hajar [2 ]
Savadroodbari, Maryam Mohammadi [3 ]
Fathollahi, Mahmood Sheikh [4 ]
机构
[1] Alborz Univ Med Sci, Dept Pediat Dent, Karaj, Iran
[2] Alborz Univ Med Sci, Student Res Comm, Katouizadeh St, Karaj 3198684868, Iran
[3] Alborz Univ Med Sci, Dept Operat Dent, Karaj, Iran
[4] Iran Univ Med Sci, Rajaie Cardiovasc Med & Res Ctr, Tehran, Iran
关键词
bulk-fill; composite resins; flowable hybrid composite; polymerization; shrinkage; RESIN-COMPOSITES; STRESS; CONVERSION; MONOMER;
D O I
10.1002/cre2.656
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objective:Since composites still face a critical problem called polymerization shrinkage and bulk-fill composites have reported acceptable results for this issue, this study aims to assess the polymerization shrinkage of a new bulk-fill flowable composite (G-aenial bulk injectable [GBI]) and compare it to other bulk-fill and conventional composites. Materials and Methods:In this in vitro study, 25 composite discs were fabricated using three bulk-fill and two conventional composites. They were bonded to a microscopic slide and were covered by a coverslip. This assembly was transferred to a linear variable differential transformer and composite samples were cured from underneath the slides. Dimensional changes formed in composite samples were recorded. Data were analyzed using analysis of variance followed by post hoc Tukey's and Dunnett's tests. Results:The groups were significantly different regarding polymerization shrinkage. G-aenial bulk injectable and G-aenial universal flo showed significantly higher polymerization shrinkage than other composites at 30, 60, and 1800 s after light irradiation, while X-tra fil and Filtek Z250 showed the lowest polymerization shrinkage at the aforementioned time points. Conclusion:According to the results, the new composite had polymerization shrinkage similar to the conventional one. Bulk-fill composites reported similar or lower shrinkage to conventional composites.
引用
收藏
页码:1605 / 1613
页数:9
相关论文
共 33 条
[1]  
Abbasi Mahdi, 2018, J Dent (Tehran), V15, P365
[2]  
Al Aqil N.S., 2020, ACAM, V9, P309
[3]   Shrinkage strain-rates of dental resin-monomer and composite systems [J].
Atai, M ;
Watts, DC ;
Atai, Z .
BIOMATERIALS, 2005, 26 (24) :5015-5020
[4]   Shrinkage behaviour of flowable resin-composites related to conversion and filler-fraction [J].
Baroudi, Kusai ;
Saleh, Abeer M. ;
Silikas, Nick ;
Watts, David C. .
JOURNAL OF DENTISTRY, 2007, 35 (08) :651-655
[5]   Factors involved in the development of polymerization shrinkage stress in resin-composites: A systematic review [J].
Braga, RR ;
Ballester, RY ;
Ferracane, JL .
DENTAL MATERIALS, 2005, 21 (10) :962-970
[6]   Clinical performance and chemical-physical properties of bulk fill composites resin -a systematic review and meta-analysis [J].
Cidreira Boaro, Leticia Cristina ;
Lopes, Diana Pereira ;
Caetano de Souza, Andreia Santos ;
Nakano, Ellea Lie ;
Ayala Perez, Mirko Dennys ;
Pfeifer, Carmem Silvia ;
Goncalves, Flavia .
DENTAL MATERIALS, 2019, 35 (10) :E249-E264
[7]   Influence of Bulk-fill Restoration on Polymerization Shrinkage Stress and Marginal Gap Formation in Class V Restorations [J].
Correia, A. M. O. ;
Andrade, M. R. ;
Tribst, J. P. M. ;
Borges, A. L. S. ;
Caneppele, T. M. F. .
OPERATIVE DENTISTRY, 2020, 45 (04) :E207-E216
[8]  
Correia T.C., 2017, REV DA FACULDADE DE, V22, P326
[9]   Post-gel and Total Shrinkage Stress of Conventional and Bulk-fill Resin Composites in Endodontically-treated Molars [J].
da Silva Pereira, R. A. ;
de Braganca, G. F. ;
Vilela, A. B. F. ;
de Deus, R. A. ;
Miranda, R. R. ;
Verissimo, C. ;
Soares, C. J. .
OPERATIVE DENTISTRY, 2020, 45 (05) :E217-E226
[10]   Evaluation of polymerization shrinkage of bulk-fill resin composites using microcomputed tomography [J].
Ersen, Kadriye Aybuke ;
Gurbuz, Ozge ;
Ozcan, Mutlu .
CLINICAL ORAL INVESTIGATIONS, 2020, 24 (05) :1687-1693