Capacitor and shunt, filter unbalance influence on the electric system harmonic response

被引:6
作者
Sainz, L [1 ]
Pedra, J [1 ]
Herraiz, S [1 ]
机构
[1] UPC, ETSEIB, Dept Elect Engn, Barcelona 08028, Spain
关键词
frequency scan; harmonic analysis; power quality;
D O I
10.1109/TPWRD.2004.838630
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
This paper studies the harmonic response of an electric power system in the presence of capacitor and shunt filter banks. The consequences in the harmonic resonant behavior of an unbalance in one of the equipment capacitors are analyzed. The obtained analytical results are validated with experimental measurements. The influence on the final results of linear and nonlinear loads is also analyzed with an example.
引用
收藏
页码:1522 / 1531
页数:10
相关论文
共 50 条
  • [41] Harmonic disturbances in electric traction system overhead lines
    Pinato, P
    Zaninelli, D
    10TH INTERNATIONAL CONFERENCE ON HARMONICS AND QUALITY OF POWER, VOLS I AND II, PROCEEDINGS, 2002, : 748 - 753
  • [42] Harmonic Suppression in a Non-Linear Load using Three Phase Shunt Active Power Filter
    Priyashree, S.
    Pooja, A. B.
    Mahesh, E.
    Vidya, H. A.
    2016 BIENNIAL INTERNATIONAL CONFERENCE ON POWER AND ENERGY SYSTEMS: TOWARDS SUSTAINABLE ENERGY (PESTSE), 2016,
  • [43] Harmonic Resonance Damping on Capacitor Bank Filters for Industrial Power System Applications
    Cleary-Balderas, A.
    Medina-Rios, A.
    2017 IEEE INTERNATIONAL AUTUMN MEETING ON POWER, ELECTRONICS AND COMPUTING (ROPEC), 2017,
  • [44] Performance Evaluation of Seven Level Reduced Switch ANPC Inverter in Shunt Active Power Filter With RBFNN-Based Harmonic Current Generation
    Sivasubramanian, M.
    Boopathi, C. S.
    Vidyasagar, S.
    Kalyanasundaram, V
    Kaliyaperumal, Saravanan
    IEEE ACCESS, 2022, 10 : 21497 - 21508
  • [45] Decoupled Controller for Simultaneous Harmonic and Unbalance Compensation in a multifunctional RES system connected to a LV Distribution Grid
    Khan, Huma
    Fernandes, B. G.
    Kulkarni, Anil
    2018 20TH EUROPEAN CONFERENCE ON POWER ELECTRONICS AND APPLICATIONS (EPE'18 ECCE EUROPE), 2018,
  • [46] IMPROVING THE QUALITY OF ELECTRIC POWER AT INDUSTRIAL ENTERPRISES THROUGH THE APPLICATION OF AN ACTIVE HARMONIC FILTER
    Klyuev, R. V.
    Bosikov, I. I.
    Gavrina, O. A.
    Golik, V. I.
    PROCEEDINGS OF THE TULA STATES UNIVERSITY-SCIENCES OF EARTH, 2022, 2 : 313 - 324
  • [47] Analysis of Active Power Filter for Harmonic Mitigation in Distribution System
    Rani, R. Sheba
    Rao, C. Srinivasa
    Kumar, M. Vijaya
    2016 INTERNATIONAL CONFERENCE ON ELECTRICAL, ELECTRONICS, AND OPTIMIZATION TECHNIQUES (ICEEOT), 2016, : 1438 - 1446
  • [48] Harmonic Filter Analysis and Redesign for a Modern Steel Facility with Two Melt Furnaces Using Dedicated Capacitor Banks
    Dionise, Thomas J.
    Lorch, Visuth
    CONFERENCE RECORD OF THE 2006 IEEE INDUSTRY APPLICATIONS CONFERENCE, FORTY-FIRST IAS ANNUAL MEETING, VOL 1-5, 2006, : 137 - 143
  • [49] Reducing Harmonic Distortion in Ship Power Systems: An Evaluation of Three Shunt Active Power Filter Control Strategies
    Tsvetanov, Dimitar
    Djagarov, Nikolay
    Djagarova, Julia
    Milushev, Hristo
    Guerrero, Josep M.
    2023 25TH EUROPEAN CONFERENCE ON POWER ELECTRONICS AND APPLICATIONS, EPE'23 ECCE EUROPE, 2023,
  • [50] A PSO based Fractional Order PI (FOPI) controller design for a Shunt Active Power Filter for Harmonic Elimination
    Srivastava, Abhishek
    Das, Dushmanta Kumar
    Kumar, Akshay
    2018 5TH IEEE UTTAR PRADESH SECTION INTERNATIONAL CONFERENCE ON ELECTRICAL, ELECTRONICS AND COMPUTER ENGINEERING (UPCON), 2018, : 1016 - 1021