Robust 2-D-3-D Registration Optimization for Motion Compensation During 3-D TRUS-Guided Biopsy Using Learned Prostate Motion Data

被引:12
作者
De Silva, Tharindu [1 ,2 ]
Cool, Derek W. [3 ]
Yuan, Jing [2 ]
Romagnoli, Cesare [3 ]
Samarabandu, Jagath [4 ]
Fenster, Aaron [2 ]
Ward, Aaron D. [5 ]
机构
[1] Johns Hopkins Univ, Dept Biomed Engn, Baltimore, MD 21205 USA
[2] Western Univ, Robarts Res Inst, London, ON N6A 5C1, Canada
[3] Western Univ, Dept Med Imaging, London, ON N6A 5C1, Canada
[4] Western Univ, Dept Elect & Comp Engn, London, ON N6A 5C1, Canada
[5] Western Univ, Dept Med Biophys, London, ON N6A 5C1, Canada
基金
加拿大健康研究院;
关键词
prostate biopsy; 2D-3D registration; motion compensation; ultrasound guidance; registration optimization; IMAGE REGISTRATION; TARGET LOCALIZATION; DIAGNOSTIC-ACCURACY; MRI; DEFORMATION; FUSION; SIMILARITY; SYSTEM;
D O I
10.1109/TMI.2017.2703150
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
In magnetic resonance (MR)-targeted, 3-D transrectal ultrasound (TRUS)-guided biopsy, prostate motion during the procedure increases the needle targeting error and limits the ability to accurately sample MR-suspicious tumor volumes. The robustness of the 2-D-3-D registration methods for prostate motion compensation is impacted by local optima in the search space. In this paper, we analyzed the prostate motion characteristics and investigated methods to incorporate such knowledge into the registration optimization framework to improve robustness against local optima. Rigid motion of the prostate was analyzed adopting a mixture-of-Gaussian (MoG) model using 3-D TRUS images acquired at bilateral sextant probe positions with a mechanically assisted biopsy system. The learned motion characteristics were incorporated into Powell's direction set method by devising multiple initial search positions and initial search directions. Experiments were performed on data sets acquired during clinical biopsy procedures, and registration error was evaluated using target registration error (TRE) and converged image similarity metric values after optimization. After incorporating the learned initialization positions and directions in Powell's method, 2-D-3-D registration to compensate for motion during prostate biopsy was performed with rms +/- std TRE of 2.33 +/- 1.09 mm with similar to 3 s mean execution time per registration. This was an improvement over 3.12 +/- 1.70 mm observed in Powell's standard approach. For the data acquired under clinical protocols, the converged image similarity metric value improved in >= 8% of the registrations whereas it degraded only <= 1% of the registrations. The reported improvements in optimization indicate use-ful advancements in robustness to ensure smooth clinical integration of a registration solution for motion compensation that facilitates accurate sampling of the smallest clinically significant tumors.
引用
收藏
页码:2010 / 2020
页数:11
相关论文
共 51 条
[1]   Diagnostic accuracy of multi-parametric MRI and TRUS biopsy in prostate cancer (PROMIS): a paired validating confirmatory study [J].
Ahmed, Hashim U. ;
Bosaily, Ahmed El-Shater ;
Brown, Louise C. ;
Gabe, Rhian ;
Kaplan, Richard ;
Parmar, Mahesh K. ;
Collaco-Moraes, Yolanda ;
Ward, Katie ;
Hindley, Richard G. ;
Freeman, Alex ;
Kirkham, Alex P. ;
Oldroyd, Robert ;
Parker, Chris ;
Emberton, Mark .
LANCET, 2017, 389 (10071) :815-822
[2]  
[Anonymous], 1987, PRACTICAL METHODS OP
[3]   Prostate biopsy tracking with deformation estimation [J].
Baumann, Michael ;
Mozer, Pierre ;
Daanen, Vincent ;
Troccaz, Jocelyne .
MEDICAL IMAGE ANALYSIS, 2012, 16 (03) :562-576
[4]  
Baumann M, 2009, LECT NOTES COMPUT SC, V5761, P67, DOI 10.1007/978-3-642-04268-3_9
[5]   Mechanically assisted 3D ultrasound guided prostate biopsy system [J].
Bax, Jeffrey ;
Cool, Derek ;
Gardi, Lori ;
Knight, Kerry ;
Smith, David ;
Montreuil, Jacques ;
Sherebrin, Shi ;
Romagnoli, Cesare ;
Fenster, Aaron .
MEDICAL PHYSICS, 2008, 35 (12) :5397-5410
[6]   Registration of planar film radiographs with computed tomography [J].
Brown, LMG ;
Boult, TE .
PROCEEDINGS OF THE IEEE WORKSHOP ON MATHEMATICAL METHODS IN BIOMEDICAL IMAGE ANALYSIS, 1996, :42-51
[7]   Registration of multiple-range views using the reverse-calibration technique [J].
Chung, DH ;
Yun, ID ;
Lee, SU .
PATTERN RECOGNITION, 1998, 31 (04) :457-464
[8]  
Correas J-M, 2013, Diagn Interv Imaging, V94, P551, DOI 10.1016/j.diii.2013.01.017
[9]   Registration of MRI to intraoperative radiographs for target localization in spinal interventions [J].
De Silva, T. ;
Uneri, A. ;
Ketcha, M. D. ;
Reaungamornrat, S. ;
Goerres, J. ;
Jacobson, M. W. ;
Vogt, S. ;
Kleinszig, G. ;
Khanna, A. J. ;
Wolinsky, J-P ;
Siewerdsen, J. H. .
PHYSICS IN MEDICINE AND BIOLOGY, 2017, 62 (02) :684-701
[10]   3D-2D image registration for target localization in spine surgery: investigation of similarity metrics providing robustness to content mismatch [J].
De Silva, T. ;
Uneri, A. ;
Ketcha, M. D. ;
Reaungamornrat, S. ;
Kleinszig, G. ;
Vogt, S. ;
Aygun, N. ;
Lo, S-F ;
Wolinsky, J-P ;
Siewerdsen, J. H. .
PHYSICS IN MEDICINE AND BIOLOGY, 2016, 61 (08) :3009-3025