Practical Guide to Ultrasound Beam Forming: Beam Pattern and Image Reconstruction Analysis

被引:35
作者
Demi, Libertario [1 ]
机构
[1] Univ Trento, Dept Informat Engn & Comp Sci, I-38123 Trento, Italy
来源
APPLIED SCIENCES-BASEL | 2018年 / 8卷 / 09期
关键词
medical ultrasound; beam forming; ultrasound imaging; multi-line acquisition; multi-line transmission; plane wave; diverging wave; synthetic aperture; parallel beam forming; beam pattern; image reconstruction; LAG SPATIAL COHERENCE; TRANSIENT ELASTOGRAPHY; MEDICAL ULTRASOUND; PLANE-WAVE; DATA-ACQUISITION; APERTURE; SYSTEM; DESIGN; GPU; BEAMFORMER;
D O I
10.3390/app8091544
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
Starting from key ultrasound imaging features such as spatial and temporal resolution, contrast, penetration depth, array aperture, and field-of-view (FOV) size, the reader will be guided through the pros and cons of the main ultrasound beam-forming techniques. The technicalities and the rationality behind the different driving schemes and reconstruction modalities will be reviewed, highlighting the requirements for their implementation and their suitability for specific applications. Techniques such as multi-line acquisition (MLA), multi-line transmission (MLT), plane and diverging wave imaging, and synthetic aperture will be discussed, as well as more recent beam-forming modalities.
引用
收藏
页数:15
相关论文
共 64 条
  • [51] REAL-TIME ORTHOGONAL MODE SCANNING OF THE HEART .1. SYSTEM-DESIGN
    SNYDER, JE
    KISSLO, J
    VONRAMM, OT
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1986, 7 (06) : 1279 - 1285
  • [52] MEDICAL ULTRASOUND IMAGING: TO GPU OR NOT TO GPU?
    So, Hayden K. -H.
    Chen, Junying
    Yiu, Billy Y. S.
    Yu, Alfred C. H.
    [J]. IEEE MICRO, 2011, 31 (05) : 54 - 65
  • [53] Szabo Thomas, 2013, Diagnostic Ultrasound Imaging: Inside Out, VSecond
  • [54] Ultrasound Transducer Selection in Clinical Imaging Practice
    Szabo, Thomas L.
    Lewin, Peter A.
    [J]. JOURNAL OF ULTRASOUND IN MEDICINE, 2013, 32 (04) : 573 - 582
  • [55] Tanter M, 2014, IEEE T ULTRASON FERR, V61, P102, DOI [10.1109/TUFFC.2014.6689779, 10.1109/TUFFC.2014.2882]
  • [56] Multi-Transmit Beam Forming for Fast Cardiac Imaging-Experimental Validation and In Vivo Application
    Tong, Ling
    Ramalli, Alessandro
    Jasaityte, Ruta
    Tortoli, Piero
    D'hooge, Jan
    [J]. IEEE TRANSACTIONS ON MEDICAL IMAGING, 2014, 33 (06) : 1205 - 1219
  • [57] Multi-Transmit Beam Forming for Fast Cardiac Imaging-A Simulation Study
    Tong, Ling
    Gao, Hang
    D'hooge, Jan
    [J]. IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2013, 60 (08) : 1719 - 1731
  • [58] Comparison of Conventional Parallel Beamforming With Plane Wave and Diverging Wave Imaging for Cardiac Applications: A Simulation Study
    Tong, Ling
    Gao, Hang
    Choi, Hon Fai
    D'hooge, Jan
    [J]. IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2012, 59 (08) : 1654 - 1663
  • [59] ULA-OP: An Advanced Open Platform for Ultrasound Research
    Tortoli, Piero
    Bassi, Luca
    Boni, Enrico
    Dallai, Alessandro
    Guidi, Francesco
    Ricci, Stefano
    [J]. IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2009, 56 (10) : 2207 - 2216
  • [60] k-Wave: MATLAB toolbox for the simulation and reconstruction of photoacoustic wave fields
    Treeby, Bradley E.
    Cox, B. T.
    [J]. JOURNAL OF BIOMEDICAL OPTICS, 2010, 15 (02)