To investigate the radiation exposure in non-vascular fluoroscopy guided interventions and to search strategies for dose reduction. Dose area product (DAP) of 638 consecutive non-vascular interventional procedures of one year were analyzed with respect to different types of interventions; gastrointestinal tract, biliary interventions, embolizations of tumors and hemorrhage. Data was analyzed with special focus on the fluoroscopy doses and frame doses. The third quartiles (Q3) of fluoroscopy dose values were defined in order to set a reference value for our in-hospital practice. Mean fluoroscopy times of gastrostomy, jejunostomy, right and left sided percutaneous biliary drainage, chemoembolization of the liver and embolization due to various hemorrhages were 5.9, 8.6, 13.5, 16.6, 17.4 and 25.2 min, respectively. The respective Q3 total DAP were 52.9, 73.3, 155.1, 308.4, 428.6 and 529.3 Gy*cm(2). Overall, around 66% of the total DAP originated from the radiographic frames with only 34% of the total DAP applied by fluoroscopy ( < 0.001). The investigators experience had no significant impact on the total DAP applied, most likely since there was no stratification to intervention-complexity. To establish Diagnostic Reference Levels (DRLs), there is a need to establish a registry of radiation dose data for the most commonly performed procedures. Documentation of interventional procedures by fluoroscopy "grabbing" has the potential to considerably reduce radiation dose applied and should be used instead of radiographic frames whenever possible.
引用
收藏
页码:613 / 620
页数:8
相关论文
共 35 条
[1]  
[Anonymous], 2001, Ann ICRP, V31, P33
[2]   How to set up and apply reference levels in fluoroscopy at a national level [J].
Aroua, A. ;
Rickli, H. ;
Stauffer, J.-C. ;
Schnyder, P. ;
Trueb, P. R. ;
Valley, J.-F. ;
Vock, P. ;
Verdun, F. R. .
EUROPEAN RADIOLOGY, 2007, 17 (06) :1621-1633
[3]   CAPTURING PATIENT DOSES FROM FLUOROSCOPICALLY BASED DIAGNOSTIC AND INTERVENTIONAL SYSTEMS [J].
Balter, Stephen .
HEALTH PHYSICS, 2008, 95 (05) :535-540
[4]  
Board NRP, 1990, DOC NRPB, V1, P1
[5]   Effects of radiologists' skill and experience on patient doses in interventional examinations [J].
Bor, Dogan ;
Sancak, Tanzer ;
Toklu, Tuerkay ;
Olgar, Turan ;
Ener, Selmin .
RADIATION PROTECTION DOSIMETRY, 2008, 129 (1-3) :32-35
[6]   ASSESSMENT OF ORGAN RADIATION-DOSES AND ASSOCIATED RISK FOR DIGITAL BIFEMORAL ARTERIOGRAPHY [J].
CASTELLANO, IA ;
MCNEILL, JG ;
THORP, NC ;
DANCE, DR ;
RAPHAEL, MJ .
BRITISH JOURNAL OF RADIOLOGY, 1995, 68 (809) :502-507
[7]   Radiation Dose and Radiation Protection for Patients and Physicians During Interventional Procedure [J].
Chida, Koichi ;
Kato, Mamoru ;
Kagaya, Yutaka ;
Zuguchi, Masayuki ;
Saito, Haruo ;
Ishibashi, Tadashi ;
Takahashi, Shoki ;
Yamada, Shogo ;
Takai, Yoshihiro .
JOURNAL OF RADIATION RESEARCH, 2010, 51 (02) :97-105
[8]   Estimation of effective dose in some digital angiographic and interventional procedures [J].
Cruces, RR ;
García-Granados, J ;
Romero, FJD ;
Armas, JH .
BRITISH JOURNAL OF RADIOLOGY, 1998, 71 (841) :42-47
[9]   The influence of angiography table shields and height on patient and angiographer irradiation during interventional radiology procedures [J].
d'Othee, Bertrand Janne ;
Lin, Pei-Jan Paul .
CARDIOVASCULAR AND INTERVENTIONAL RADIOLOGY, 2007, 30 (03) :448-454
[10]  
International Commission on Radiological Protection, 2007, ANN ICRP, V37, P1