Enhancing the Coverage of the Urinary Metabolome by Sheathless Capillary Electrophoresis-Mass Spectrometry

被引:101
作者
Ramautar, Rawi [1 ]
Busnel, Jean-Marc [1 ,2 ]
Deelder, Andre M. [1 ]
Mayboroda, Oleg A. [1 ]
机构
[1] Leiden Univ, Med Ctr, Dept Parasitol, Biomol Mass Spectrometry Unit, Leiden, Netherlands
[2] Beckman Coulter Inc, Brea, CA 92822 USA
关键词
POROUS TIP; CE-MS; INTERFACE; PEPTIDES; DATABASE;
D O I
10.1021/ac202407v
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Sheath less capillary electrophoresis-mass spectrometry (CE-MS), using a porous tip sprayer, is proposed for the first time for highly sensitive metabolic profiling of human urine. A representative metabolite mixture and human urine were used for evaluation of the sheathless CE-MS platform. For test compounds, relative standard deviations (RSDs) for migration times and peak areas were below 2% and 12%, respectively, and an injection volume of only similar to 8 nL resulted in detection limits between 11 and 120 nM. Approximately 900 molecular features were detected in human urine by sheathless CE-MS whereas about 300 molecular features were found with classical sheath-liquid CE-MS. This difference can probably be attributed to an improved ionization efficiency and increased sensitivity at low flow-rate conditions. The integration of transient-isotachophoresis (t-ITP) as an in-capillary preconcentration procedure in sheathless CE-MS further resulted in subnanomolar limits of detection for compounds of the metabolite mixture, and more than 1300 molecular features were observed in urine. Compared to the classical CE-MS approaches, the integration of t-ITP combined with the use of a sheathless interface provides up to 2 orders of magnitude sensitivity improvement. Hence, sheathless CE-MS can be used for in-depth metabolic profiling of biological samples, and we anticipate that this approach will yield unique information in the field of metabolomics.
引用
收藏
页码:885 / 892
页数:8
相关论文
共 26 条
[1]   Capillary electrophoresis-Fourier transform ion cyclotron resonance mass Spectrometry for the identification of cationic metabolites via a pH-mediated stacking-transient isotachophoretic method [J].
Baidoo, Edward E. K. ;
Benket, Peter I. ;
Neususs, Christian ;
Pelzing, Matthias ;
Kruppa, Gary ;
Leary, Julie A. ;
Keasling, Jay D. .
ANALYTICAL CHEMISTRY, 2008, 80 (09) :3112-3122
[2]  
Britz-McKibbin P, 2011, METHODS MOL BIOL, V708, P229, DOI 10.1007/978-1-61737-985-7_14
[3]   High Capacity Capillary Electrophoresis-Electrospray Ionization Mass Spectrometry: Coupling a Porous Sheathless Interface with Transient-Isotachophoresis [J].
Busnel, Jean-Marc ;
Schoenmaker, Bart ;
Ramautar, Rawi ;
Carrasco-Pancorbo, Alegria ;
Ratnayake, Chitra ;
Feitelson, Jerald S. ;
Chapman, Jeff D. ;
Deelder, Andre M. ;
Mayboroda, Oleg A. .
ANALYTICAL CHEMISTRY, 2010, 82 (22) :9476-9483
[4]   Efficient and highly reproducible capillary electrophoresis-mass spectrometry of peptides using Polybrene-poly(vinyl sulfonate)-coated capillaries [J].
Catai, Jonatan R. ;
Torano, Javier Sastre ;
de Jong, Gerhardus J. ;
Somsen, Govert W. .
ELECTROPHORESIS, 2006, 27 (11) :2091-2099
[5]   Virtual Quantification of Metabolites by Capillary Electrophoresis-Electrospray Ionization-Mass Spectrometry: Predicting Ionization Efficiency Without Chemical Standards [J].
Chalcraft, Kenneth R. ;
Lee, Richard ;
Mills, Casandra ;
Britz-McKibbin, Philip .
ANALYTICAL CHEMISTRY, 2009, 81 (07) :2506-2515
[6]   Comprehensive Plasma Thiol Redox Status Determination for Metabolomics [J].
D'Agostino, Lisa A. ;
Lam, Karen P. ;
Lee, Richard ;
Britz-McKibbin, Philip .
JOURNAL OF PROTEOME RESEARCH, 2011, 10 (02) :592-603
[7]   Analysis of complex protein mixtures with improved sequence coverage using (CE-MS/MS)n [J].
Garza, Selynda ;
Moini, Mehdi .
ANALYTICAL CHEMISTRY, 2006, 78 (20) :7309-7316
[8]   Global metabolic profiling analysis on human urine by UPLC-TOFMS: Issues and method validation in nutritional metabolomics [J].
Guy, Philippe A. ;
Tavazzi, Isabelle ;
Bruce, Stephen J. ;
Ramadan, Ziad ;
Kochhar, Sunil .
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2008, 871 (02) :253-260
[9]   Performance of a sheathless porous tip sprayer for capillary electrophoresis-electrospray ionization-mass spectrometry of intact proteins [J].
Haselberg, Rob ;
Ratnayake, Chitra K. ;
de Jong, Gerhardus J. ;
Somsen, Govert W. .
JOURNAL OF CHROMATOGRAPHY A, 2010, 1217 (48) :7605-7611
[10]   A sheathless nanoflow electrospray interface for on-line capillary electrophoresis mass spectrometry [J].
Janini, GM ;
Conrads, TP ;
Wilkens, KL ;
Issaq, HJ ;
Veenstra, TD .
ANALYTICAL CHEMISTRY, 2003, 75 (07) :1615-1619