Impedance spectra analysis to characterize interdigitated electrodes as electrochemical sensors

被引:31
作者
Rana, Sunil [1 ]
Page, Robin H. [1 ]
McNeil, Calum J. [1 ]
机构
[1] Newcastle Univ, Sch Med, Inst Cellular Med, Newcastle Upon Tyne NE2 4HH, Tyne & Wear, England
关键词
Electrochemical impedance spectroscopy; Interdigitated electrodes; Geometric capacitance; Solution resistance; Solution conductivity; IMPEDIMETRIC IMMUNOSENSOR; BIOSENSORS;
D O I
10.1016/j.electacta.2011.07.055
中图分类号
O646 [电化学、电解、磁化学];
学科分类号
081704 ;
摘要
Interdigitated electrode (IDE) arrays have been used widely for electrochemical impedance spectroscopy (EIS). Here, we present an in-depth analysis of interdigitated electrode impedance spectra. Such an analysis is necessary for the identification of the contribution of each interdigitated electrode circuit element to the impedance change. We also discuss the importance of the solution conductivity in impedance spectroscopy showing that the use of low conductivity solutions is advantageous when inter-digit solution resistance and geometric capacitance need to be monitored. (C) 2011 Elsevier Ltd. All rights reserved.
引用
收藏
页码:8559 / 8563
页数:5
相关论文
共 14 条
[1]   An impedimetric immunosensor for the detection of autoantibodies directed against gliadins [J].
Balkenhohl, T. ;
Lisdat, F. .
ANALYST, 2007, 132 (04) :314-322
[2]   Three-dimensional interdigitated electrode array as a transducer for label-free biosensors [J].
Bratov, Andrey ;
Ramon-Azcon, Javier ;
Abramova, Natalia ;
Merlos, Angel ;
Adrian, Javier ;
Sanchez-Baeza, Francisco ;
Marco, Maria-Pilar ;
Dominguez, Carlos .
BIOSENSORS & BIOELECTRONICS, 2008, 24 (04) :729-735
[3]   Label-free impedance biosensors: Opportunities and challenges [J].
Daniels, Jonathan S. ;
Pourmand, Nader .
ELECTROANALYSIS, 2007, 19 (12) :1239-1257
[4]   Disposable noncompetitive immunosensor for free and total prostate-specific antigen based on capacitance measurement [J].
Fernández-Sánchez, C ;
McNeil, CJ ;
Rawson, K ;
Nilsson, O .
ANALYTICAL CHEMISTRY, 2004, 76 (19) :5649-5656
[5]  
Fernández-Sánchez C, 2004, ELECTROCHEM COMMUN, V6, P138, DOI 10.1016/j.elecom.11.002
[6]  
GALLARDO A, 2002, CHEM ENG, V734, P30
[7]   Convective instability of ferro-ferricyanide solution in plane interelectrode space [J].
Grigin, AP ;
Davydov, AD .
RUSSIAN JOURNAL OF ELECTROCHEMISTRY, 2000, 36 (03) :286-291
[8]   Probing biomolecular interactions at conductive and semiconductive surfaces by impedance spectroscopy: Routes to impedimetric immunosensors, DNA-Sensors, and enzyme biosensors [J].
Katz, E ;
Willner, I .
ELECTROANALYSIS, 2003, 15 (11) :913-947
[9]   Nanoscaled interdigitated titanium electrodes for impedimetric biosensing [J].
Laureyn, W ;
Nelis, D ;
Van Gerwen, P ;
Baert, K ;
Hermans, L ;
Magnée, R ;
Pireaux, JJ ;
Maes, G .
SENSORS AND ACTUATORS B-CHEMICAL, 2000, 68 (1-3) :360-370
[10]   ELECTROCHEMICAL SENSORS BASED ON IMPEDANCE MEASUREMENT OF ENZYME-CATALYZED POLYMER DISSOLUTION - THEORY AND APPLICATIONS [J].
MCNEIL, CJ ;
ATHEY, D ;
BALL, M ;
HO, WO ;
KRAUSE, S ;
ARMSTRONG, RD ;
WRIGHT, JD ;
RAWSON, K .
ANALYTICAL CHEMISTRY, 1995, 67 (21) :3928-3935