Diagnostic yield of endoscopic ultrasound-guided liver biopsy in comparison to percutaneous liver biopsy: a systematic review and meta-analysis

被引:17
作者
Facciorusso, Antonio [1 ,2 ]
Crino, Stefano Francesco [2 ]
Ramai, Daryl [3 ]
Fabbri, Carlo [4 ]
Mangiavillano, Benedetto [5 ]
Lisotti, Andrea [6 ]
Muscatiello, Nicola [1 ]
Cotsoglou, Christian [7 ]
Fusaroli, Pietro [6 ]
机构
[1] Osped Riuniti Di Foggia, Sect Gastroenterol, Dept Med & Surg Sci, Foggia, Italy
[2] Univ Hosp Verona, Pancreas Inst, Gastroenterol & Digest Endoscopy Unit, Dept Med, Verona, Italy
[3] Brooklyn Hosp, Gastroenterol & Hepatol, Med Ctr, Brooklyn, NY USA
[4] Forli Cesena Hosp, Gastroenterol & Digest Endoscopy Unit, Ausl Romagna, Forli Cesena, Italy
[5] Humanitas Mater Domini, Gastrointestinal Endoscopy Unit, Castellanza, Italy
[6] Univ Bologna, Hosp Imola, Gastroenterol Unit, Bologna, Italy
[7] ASST Brianza, Vimercate Hosp, Gen Surg Unit, Vimercate, Italy
关键词
EUS; FNB; FNA; adequacy; FINE-NEEDLE-ASPIRATION; PANCREATIC LESIONS; ANTIVIRAL THERAPY; HEPATITIS-C; FORK-TIP; STIFFNESS; SAFETY;
D O I
10.1080/17474124.2022.2020645
中图分类号
R57 [消化系及腹部疾病];
学科分类号
摘要
Background It is still unclear whether endoscopic ultrasound liver biopsy (EUS-LB) determines superior results in comparison to percutaneous liver biopsy (PC-LB). Aim of this meta-analysis was to compare the diagnostic outcomes of these two techniques. Research Design and Methods Literature search was conducted through June 2021 and identified 7 studies. The primary outcome was total length of specimen. Results were expressed as odds ratio (OR) or mean difference along with 95% confidence interval (CI). Results Pooled total length of specimen was 29.9 mm (95% CI 24.1-35.7) in the EUS-LB group and 29.7 mm (95% CI 27.1-32.2) in the PC-LB group, with no difference between the two approaches (mean difference -0.35 mm, 95% CI -5.31 to 4.61; p = 0.89), although sensitivity analysis restricted to higher quality studies found a superior performance of PC-LB over EUS-LB. Pooled number of complete portal tracts was 12.9 (7.7-18) in the EUS-LB and 14.4 (10.7-18) in the PC-LB group, with no difference in direct comparison (mean difference -1.58, -5.98 to 2.81; p = 0.48). No difference between the two groups was observed in terms of severe adverse event rate (OR 1.11, 0.11-11.03; p = 0.93). Conclusion EUS-LB and PC-LB are comparable in terms of diagnostic performance and safety profile.
引用
收藏
页码:51 / 57
页数:7
相关论文
共 29 条
  • [11] Diagnostic Yield of Endoscopic Ultrasound-Guided Liver Biopsy in Comparison to Percutaneous Liver Biopsy: A Two-Center Experience
    Facciorusso, Antonio
    Ramai, Daryl
    Bellocchi, Maria Cristina Conti
    Bernardoni, Laura
    Manfrin, Erminia
    Muscatiello, Nicola
    Crino, Stefano Francesco
    [J]. CANCERS, 2021, 13 (12)
  • [12] Comparison between fine-needle biopsy and fine-needle aspiration for EUS-guided sampling of subepithelial lesions: a meta-analysis
    Facciorusso, Antonio
    Sunny, Sumsum P.
    Del Prete, Valentina
    Antonino, Matteo
    Muscatiello, Nicola
    [J]. GASTROINTESTINAL ENDOSCOPY, 2020, 91 (01) : 14 - +
  • [13] Comparative accuracy of needle sizes and designs for EUS tissue sampling of solid pancreatic masses: a network meta-analysis
    Facciorusso, Antonio
    Wani, Sachin
    Triantafyllou, Konstantinos
    Tziatzios, Georgios
    Cannizzaro, Renato
    Muscatiello, Nicola
    Singh, Siddharth
    [J]. GASTROINTESTINAL ENDOSCOPY, 2019, 90 (06) : 893 - +
  • [14] Systematic review with meta-analysis: Change in liver stiffness during anti-viral therapy in patients with hepatitis B
    Facciorusso, Antonio
    Garcia Perdomo, Herney Andres
    Muscatiello, Nicola
    Buccino, Rosario Vincenzo
    Wong, Vincent Wai-Sun
    Singh, Siddharth
    [J]. DIGESTIVE AND LIVER DISEASE, 2018, 50 (08) : 787 - 794
  • [15] Long-term liver stiffness assessment in hepatitis C virus patients undergoing antiviral therapy: Results from a 5-year cohort study
    Facciorusso, Antonio
    Del Prete, Valentina
    Turco, Antonio
    Buccino, Rosario Vincenzo
    Nacchiero, Maurizio Cosimo
    Muscatiello, Nicola
    [J]. JOURNAL OF GASTROENTEROLOGY AND HEPATOLOGY, 2018, 33 (04) : 942 - 949
  • [16] Endoscopic ultrasound-guided fine needle aspiration of pancreatic lesions with 22 versus 25 Gauge needles: A meta-analysis
    Facciorusso, Antonio
    Stasi, Elisa
    Di Maso, Marianna
    Serviddio, Gaetano
    Ali Hussein, Mohammed Salah
    Muscatiello, Nicola
    [J]. UNITED EUROPEAN GASTROENTEROLOGY JOURNAL, 2017, 5 (06) : 846 - 853
  • [17] Guyatt GH, 2011, J CLIN EPIDEMIOL, V64, P1311, DOI [10.1016/j.jclinepi.2011.06.004, 10.1016/j.jclinepi.2011.03.017]
  • [18] The Cochrane Collaboration's tool for assessing risk of bias in randomised trials
    Higgins, Julian P. T.
    Altman, Douglas G.
    Gotzsche, Peter C.
    Jueni, Peter
    Moher, David
    Oxman, Andrew D.
    Savovic, Jelena
    Schulz, Kenneth F.
    Weeks, Laura
    Sterne, Jonathan A. C.
    [J]. BMJ-BRITISH MEDICAL JOURNAL, 2011, 343
  • [19] Safety of percutaneous versus transjugular liver biopsy: A propensity score matched analysis
    Lavian, J. D.
    Thornton, L. M.
    Zybulewski, A.
    Kim, E.
    Nowakowski, S. F.
    Ranade, M.
    Patel, R. S.
    Lookstein, R. A.
    Fischman, A.
    Bishay, V
    [J]. EUROPEAN JOURNAL OF RADIOLOGY, 2020, 133
  • [20] Endoscopic Ultrasound-Guided, Percutaneous, and Transjugular Liver Biopsy: A Comparative Systematic Review and Meta-Analysis
    McCarty, Thomas R.
    Bazarbashi, Ahmad Najdat
    Njei, Basile
    Ryou, Marvin
    Aslanian, Harry R.
    Muniraj, Thiruvengadam
    [J]. CLINICAL ENDOSCOPY, 2020, 53 (05) : 583 - 593