Comparative Study on Determination of Proteins by High Performance Liquid Chromatography with Ultraviolet or Laser-Induced Fluorescence as Detector

被引:2
作者
Ma Li-Min [1 ,2 ]
Song Lun [1 ,2 ]
Qian Jun-Hong [1 ,2 ]
Zhang Ling-Yi [1 ,2 ]
Lan Min-Bo [1 ,2 ,3 ]
Zhang Wei-Bing [1 ,2 ]
机构
[1] E China Univ Sci & Technol, Shanghai Key Lab Funct Mat Chem, Shanghai 200237, Peoples R China
[2] E China Univ Sci & Technol, Res Ctr Anal & Test, Shanghai 200237, Peoples R China
[3] E China Univ Sci & Technol, State Key Lab Bioreactor Engn, Shanghai 200237, Peoples R China
关键词
Proteins; Peptides; Laser-induced fluorescence; High performance liquid chroma-tography; CAPILLARY-ELECTROPHORESIS; PEPTIDES; 4-FLUORO-7-NITRO-2,1,3-BENZOXADIAZOLE; LIF;
D O I
10.3724/SP.J.1096.2011.01027
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The protein sample extracted from rat liver tumor tissues and its enzymic hydrolysates were detected by high performance liquid chromatography-laser induced fluorescence detector(HPLC-LIF) (lambda(ex) = 473nm, lambda(em) = 525 nm) after labeled with 4-fluoro-7-nitro-2, 1, 3-benzoxadiazole (NBD-F) in dark at room temperature for 1 h with borate buffer (50 mmol/L, pH = 8.5) as reaction medium, and the results were compared with those obtained from HPLC-UV (at 214nm) without derivatization. The analysis of enzymic hydrolysates shows that LIP detector can greatly improve the detection by its high sensitivity: the peak intensities of most components are 10 times higher than UV detection and 42 peaks more were observed. For the analysis of protein sample, most of the peaks detected by UV are located in strong polarity area, which indicates that these components with strong polarity have high UV absorption. The signals obtained from LIF are located in weak polarity or non-polarity area. One reason is that derivatization can change the polarity of the components, and the other is that components with weak or non-polarity might be labeled more easily. This result also suggests selectivity difference between these two methods over the real protein sample. In addition, selective label of complex sample by changing reaction conditions (such as pH and reaction media) enables to achieve high sensitive detection of low abundance proteins and peptides with better selectivity.
引用
收藏
页码:1027 / 1032
页数:6
相关论文
共 18 条
  • [1] Protein profile analysis of cellular samples from the cervix for the objective diagnosis of cervical cancer using HPLC-LIF
    Bhat, Sujatha
    Patil, Ajeetkumar
    Rai, Lavanya
    Kartha, V. B.
    Santhosh, C.
    [J]. JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2010, 878 (31): : 3225 - 3230
  • [2] Novel strategy of high-abundance protein depletion using multidimensional liquid chromatography
    Gao, Mingxia
    Zhang, Jie
    Deng, Chunhui
    Yang, Pengyuan
    Zhang, Xiangmin
    [J]. JOURNAL OF PROTEOME RESEARCH, 2006, 5 (10) : 2853 - 2860
  • [3] LIF detection of peptides and proteins in CE
    Garcia-Campana, Ana M.
    Taverna, Myriam
    Fabre, Huguette
    [J]. ELECTROPHORESIS, 2007, 28 (1-2) : 208 - 232
  • [4] Guo S, 2009, CHINESE J ANAL CHEM, V37, P242
  • [5] HIROSHI M, 1985, ANAL CHIM ACTA, V170, P81
  • [6] Quantification of immunoglobulin G and characterization of process related impurities using coupled Protein A and size exclusion high performance liquid chromatography
    Horak, Jeannie
    Ronacher, Alexander
    Lindner, Wolfgang
    [J]. JOURNAL OF CHROMATOGRAPHY A, 2010, 1217 (31) : 5092 - 5102
  • [7] Tandem Laser-Induced Fluorescence and Mass Spectrometry Detection for High-Performance Liquid Chromatography Analysis of the in Vitro Metabolism of Doxorubicin
    Katzenmeyer, Joseph B.
    Eddy, Christopher V.
    Arriaga, Edgar A.
    [J]. ANALYTICAL CHEMISTRY, 2010, 82 (19) : 8113 - 8120
  • [8] 4-fluoro-7-nitro-2,1,3-benzoxadiazole as a fluorogenic labeling reagent for the in vivo analysis of amino acid neurotransmitters using online microdialysis-capillary electrophoresis
    Klinker, Chanda Ciriacks
    Bowser, Michael T.
    [J]. ANALYTICAL CHEMISTRY, 2007, 79 (22) : 8747 - 8754
  • [9] Protein profile study of breast-tissue homogenates by HPLC-LIF
    Kumar, K. Kalyan
    Chowdary, M. V. P.
    Mathew, Stanley
    Rao, Lakshmi
    Krishna, C. Murali
    Kurien, Jacob
    [J]. JOURNAL OF BIOPHOTONICS, 2009, 2 (05) : 313 - 321
  • [10] Laser-induced fluorescence detection schemes for the analysis of proteins and peptides using capillary electrophoresis
    Lacroix, M
    Poinsot, V
    Fournier, C
    Couderc, F
    [J]. ELECTROPHORESIS, 2005, 26 (13) : 2608 - 2621