Echocardiographic and angiographic assessment of paravalvular regurgitation after TAVI: optimizing inter-technique reproducibility

被引:21
作者
Abdelghani, Mohammad [1 ]
Tateishi, Hiroki [2 ]
Spitzer, Ernest [3 ]
Tijssen, Jan G. [1 ]
de Winter, Robbert J. [1 ]
Soliman, Osama I. I. [2 ,3 ]
Hahn, Rebecca T. [4 ]
Serruys, Patrick W. [5 ]
机构
[1] Acad Med Ctr, Amsterdam, Netherlands
[2] Erasmus MC, Thoraxctr, Rotterdam, Netherlands
[3] Cardialysis Core Labs & Clin Trial Management, Rotterdam, Netherlands
[4] Columbia Univ, Med Ctr, New York Presbyterian Hosp, New York, NY USA
[5] Imperial Coll London, NHLI, Int Ctr Circulatory Hlth, London, England
关键词
Aortic regurgitation; Angiography; Doppler echocardiography; Transcatheter aortic valve implantation; TRANSCATHETER AORTIC-VALVE; NATIVE VALVULAR REGURGITATION; EDWARDS SAPIEN-XT; TRANSTHORACIC ECHOCARDIOGRAPHY; EUROPEAN ASSOCIATION; MEDTRONIC COREVALVE; MAGNETIC-RESONANCE; IMPLANTATION; REPLACEMENT; SEVERITY;
D O I
10.1093/ehjci/jew083
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Aims Aortic regurgitation (AR) after transcatheter aortic valve implantation (TAVI) is often first diagnosed by angiography and then confirmed and followed-up by transthoracic echocardiography (TTE). Consistency between bothmethods is important for follow-up. We sought to determine inter-technique reproducibility of the assessment of paravalvular AR after TAVI. Methods and results The study included 165 patients treated with a self-expanding bioprosthesis and had angiography and TTE performed at a median interval of 4 days. TTE parameters of AR severity included VARC score (the average AR grade determined by the echocardiographic VARC-II criteria), pressure half time (PHT), regurgitation jet features in long-axis views (LAX score) and colour Doppler (CD) score (= paravalvular AR jet circumferential extent (%) + LAX score). Using receiver-operating characteristics curves, the cut-points that best defined an angiographic. mild AR were identified. On TTE, AR was paravalvular in all cases, multi-jet in 28%, and predominantly (64%) detected in the commissural region between the right and left coronary sinuses. Using VARC-II criteria (combining at least two), TTE agreed with angiographic classification in 53% of cases (k = 0.14). Greater than mild AR could better be defined by one of the following combinations of criteria: (i) LAX score >4.25 and VARC-II score >1.33; (ii) CD score >11.5 and PHT < 400 ms. The combination of the CD score with PHT gave the best sum of sensitivity, specificity, positive, and negative predictive values. Conclusions Agreement between angiography and TTE (using the VARC-II criteria) in the grading of post-TAVI AR is modest, and this might have contributed to the inconsistency of data on the rate and fate of paravalvular AR. Inter-technique reproducibility can be improved using a combination of CD and hemodynamic parameters.
引用
收藏
页码:852 / 860
页数:9
相关论文
共 46 条
  • [1] Transcatheter Aortic-Valve Replacement with a Self-Expanding Prosthesis
    Adams, David H.
    Popma, Jeffrey J.
    Reardon, Michael J.
    Yakubov, Steven J.
    Coselli, Joseph S.
    Deeb, G. Michael
    Gleason, Thomas G.
    Buchbinder, Maurice
    Hermiller, James, Jr.
    Kleiman, Neal S.
    Chetcuti, Stan
    Heiser, John
    Merhi, William
    Zorn, George
    Tadros, Peter
    Robinson, Newell
    Petrossian, George
    Hughes, G. Chad
    Harrison, J. Kevin
    Conte, John
    Maini, Brijeshwar
    Mumtaz, Mubashir
    Chenoweth, Sharla
    Oh, Jae K.
    [J]. NEW ENGLAND JOURNAL OF MEDICINE, 2014, 370 (19) : 1790 - 1798
  • [2] Incidence, Predictors, and Outcomes of Aortic Regurgitation After Transcatheter Aortic Valve Replacement Meta-Analysis and Systematic Review of Literature
    Athappan, Ganesh
    Patvardhan, Eshan
    Tuzcu, E. Murat
    Svensson, Lars Georg
    Lemos, Pedro A.
    Fraccaro, Chiara
    Tarantini, Giuseppe
    Sinning, Jan-Malte
    Nickenig, Georg
    Capodanno, Davide
    Tamburino, Corrado
    Latib, Azeem
    Colombo, Antonio
    Kapadia, Samir R.
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2013, 61 (15) : 1585 - 1595
  • [3] Comparison of Transfemoral Transcatheter Aortic Valve Replacement Performed in the Catheterization Laboratory (Minimalist Approach) Versus Hybrid Operating Room (Standard Approach) Outcomes and Cost Analysis
    Babaliaros, Vasilis
    Devireddy, Chandan
    Lerakis, Stamatios
    Leonardi, Robert
    Iturra, Sebastian A.
    Mavromatis, Kreton
    Leshnower, Bradley G.
    Guyton, Robert A.
    Kanitkar, Mihir
    Keegan, Patricia
    Simone, Amy
    Stewart, James P.
    Ghasemzadeh, Nima
    Block, Peter
    Thourani, Vinod H.
    [J]. JACC-CARDIOVASCULAR INTERVENTIONS, 2014, 7 (08) : 898 - 904
  • [4] LIMITATIONS OF QUALITATIVE ANGIOGRAPHIC GRADING IN AORTIC OR MITRAL REGURGITATION
    CROFT, CH
    LIPSCOMB, K
    MATHIS, K
    FIRTH, BG
    NICOD, P
    TILTON, G
    WINNIFORD, MD
    HILLIS, LD
    [J]. AMERICAN JOURNAL OF CARDIOLOGY, 1984, 53 (11) : 1593 - 1598
  • [5] Quantitative assessment of paravalvular regurgitation following transcatheter aortic valve replacement
    Crouch, Gareth
    Tully, Phillip J.
    Bennetts, Jayme
    Sinhal, Ajay
    Bradbrook, Craig
    Penhall, Amy L.
    De Pasquale, Carmine G.
    Baker, Robert A.
    Selvanayagam, Joseph B.
    [J]. JOURNAL OF CARDIOVASCULAR MAGNETIC RESONANCE, 2015, 17
  • [6] Efficacy and Safety of Postdilatation to Reduce Paravalvular Regurgitation During Balloon-Expandable Transcatheter Aortic Valve Replacement
    Daneault, Benoit
    Koss, Elana
    Hahn, Rebecca T.
    Kodali, Susheel
    Williams, Mathew R.
    Genereux, Philippe
    Paradis, Jean-Michel
    George, Isaac
    Reiss, George R.
    Moses, Jeffrey W.
    Smith, Craig R.
    Leon, Martin B.
    [J]. CIRCULATION-CARDIOVASCULAR INTERVENTIONS, 2013, 6 (01) : 85 - 91
  • [7] Aortic valve, periprosthetic leakage: Anatomic observations and surgical results
    De Cicco, G
    Lorusso, R
    Colli, A
    Nicolini, F
    Fragnito, C
    Grimaldi, T
    Borrello, B
    Budillon, AM
    Gherli, T
    Beghi, C
    [J]. ANNALS OF THORACIC SURGERY, 2005, 79 (05) : 1480 - 1485
  • [8] Determinants of Significant Paravalvular Regurgitation After Transcatheter Aortic Valve Implantation Impact of Device and Annulus Discongruence
    Detaint, Delphine
    Lepage, Laurent
    Himbert, Dominique
    Brochet, Eric
    Messika-Zeitoun, David
    Iung, Bernard
    Vahanian, Alec
    [J]. JACC-CARDIOVASCULAR INTERVENTIONS, 2009, 2 (09) : 821 - 827
  • [9] Feasibility and Safety of Early Discharge After Transfemoral Transcatheter Aortic Valve Implantation With the Edwards SAPIEN-XT Prosthesis
    Durand, Eric
    Eltchaninoff, Helene
    Canville, Alexandre
    Bouhzam, Najime
    Godin, Matthieu
    Tron, Christophe
    Rodriguez, Carlos
    Litzler, Pierre-Yves
    Bauer, Fabrice
    Cribier, Alain
    [J]. AMERICAN JOURNAL OF CARDIOLOGY, 2015, 115 (08) : 1116 - 1122
  • [10] Registry of Transcatheter Aortic-Valve Implantation in High-Risk Patients
    Gilard, Martine
    Eltchaninoff, Helene
    Iung, Bernard
    Donzeau-Gouge, Patrick
    Chevreul, Karine
    Fajadet, Jean
    Leprince, Pascal
    Leguerrier, Alain
    Lievre, Michel
    Prat, Alain
    Teiger, Emmanuel
    Lefevre, Thierry
    Himbert, Dominique
    Tchetche, Didier
    Carrie, Didier
    Albat, Bernard
    Cribier, Alain
    Rioufol, Gilles
    Sudre, Arnaud
    Blanchard, Didier
    Collet, Frederic
    Dos Santos, Pierre
    Meneveau, Nicolas
    Tirouvanziam, Ashok
    Caussin, Christophe
    Guyon, Philippe
    Boschat, Jacques
    Le Breton, Herve
    Collart, Frederic
    Houel, Remi
    Delpine, Stephane
    Souteyrand, Geraud
    Favereau, Xavier
    Ohlmann, Patrick
    Doisy, Vincent
    Grollier, Gilles
    Gommeaux, Antoine
    Claudel, Jean-Philippe
    Bourlon, Francois
    Bertrand, Bernard
    Van Belle, Eric
    Laskar, Marc
    [J]. NEW ENGLAND JOURNAL OF MEDICINE, 2012, 366 (18) : 1705 - 1715