Gonioscopic changes after implantation of a posterior chamber lens in phakic myopic eyes

被引:36
作者
Abela-Formanek, C [1 ]
Kruger, AJ [1 ]
Dejaco-Ruhswurm, I [1 ]
Pieh, S [1 ]
Skorpik, C [1 ]
机构
[1] Univ Vienna, Sch Med, Dept Ophthalmol, A-1090 Vienna, Austria
关键词
D O I
10.1016/S0886-3350(01)01229-9
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To evaluate the effects of posterior chamber implantation of phakic intraocular lenses on angle structures and the correlation with intraocular pressure (IOP). Setting: Department of Ophthalmology, University Hospital of Vienna, Vienna, Austria. Methods: A Staar implantable contact lens (ICL) was implanted in 20 white patients (34 eyes) with high myopia. The patients were followed for a mean of 2.3 years (range 0.8 to 6.0 years), Two subgroups were created: One had a follow-up of 2.4 to 6.0 years and the other, 0.8 to 2.3 years. The mean spherical power of the implanted ICL was -16.8 diopters (D) (range -9.0 to -21.0 D). The angle structures were examined by gonioscopy using the Spaeth technique, and optical pachymetry and IOP were measured in dilated and undilated pupils. Trabecular pigmentation was measured semiquantitatively. The ICL models included a few prototypes (6 eyes), the V2 model (10 eyes), the V3 model (6 eyes), and the V4 model (12 eyes). Results: The anterior chamber angle was between 11 and 20 degrees in 41% of eyes, between 21 and 30 degrees in 21%, larger than 30 degrees in 21%, and 10 degrees or smaller in 17%, An apparent iris root insertion was above Schwalbe's line in 6% of eyes, behind Schwalbe's line in 12%, at the scleral spur in 67%, and in a deep angle recess behind the scleral spur in 15%. The curvature of the iris was regular in 19 eyes and steep in 15 eyes. The mean pigmentation in all 4 quadrants was 1.3. (Grade 1 was defined as trace pigmentation.) The mean pachymetry from the endothelium to the ICL anterior surface was 2.7 mm and from the endothelium to the anterior surface of the crystalline lens, 3.2 mm. The mean IOP was 14.1 mm Hg in undilated pupils and 12.1 mm Hg in dilated pupils. There was no correlation between angle pigmentation and IOP. Conclusion: Trace pigmentation in the trabecular meshwork was common after ICL implantation. However, there was no direct influence on IOP. Long-term follow-up is necessary to evaluate the effect and progress of trabecular pigmentation in eyes with an (C) 2001 ASCPS and ESCRS.
引用
收藏
页码:1919 / 1925
页数:7
相关论文
共 17 条
[11]  
Pesando PM, 1999, J REFRACT SURG, V15, P415
[12]   Staar Collamer posterior chamber phakic intraocular lens to correct myopia and hyperopia [J].
Rosen, E ;
Gore, C .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 1998, 24 (05) :596-606
[13]   Implantable contact lens for moderate to high myopia: Phase 1 FDA clinical study with 6 month follow-up [J].
Sanders, DR ;
Brown, DC ;
Martin, RG ;
Shepherd, J ;
Deitz, MR ;
DeLuca, M .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 1998, 24 (05) :607-611
[14]  
SKORPIK C, 2000, K DEUTSCHSPR GES INT, P554
[15]  
SKORPIK C, 1999, IMPLANTABLE CONTACT, P315
[16]  
Spaeth G L, 1971, Trans Ophthalmol Soc U K, V91, P709
[17]  
Trindade F, 1999, J CATARACT REFR SURG, V25, P461, DOI 10.1016/S0886-3350(99)80033-9