Refractive outcomes and accuracy of IOL power calculation with the SRK/T formula for sutured, scleral-fixated Akreos AO60 intraocular lenses

被引:12
作者
Ohr, Matthew P. [1 ]
Wisely, C. Ellis [2 ]
机构
[1] Ohio State Univ, Dept Ophthalmol, 915 Olentangy River Rd Suite 5000, Columbus, OH 43212 USA
[2] Duke Univ, Dept Ophthalmol, Durham, NC USA
关键词
Sutured lens; Akreos; Gore-Tex; IOL power calculation; SRK; T formula; BIOMETRY; ABSENCE;
D O I
10.1007/s00417-020-04721-9
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Background Scleral fixation of intraocular lenses has become a popular procedure for treating aphakia in the absence of capsular support. However, the lens formulas used to predict refractive outcomes were designed for in-the-bag lens placement. This study evaluates the accuracy of the SRK/T formula in predicting a target postoperative refraction when suturing a scleral-fixated intraocular lens (IOL) implant 3 mm posterior to the limbus. Methods This is a retrospective, case series including 20 eyes of 20 patients who underwent scleral fixation of Akreos AO60 IOLs (Bausch & Lomb, Rochester, NY) by a single surgeon at the OSU Wexner Medical Center. Preoperative measurements were performed with optical biometry, and IOL power was calculated with the SRK/T formula. Following surgery, the actual refractive spherical equivalent (SE) was performed and compared with the preoperative prediction. Prediction error (PE), defined as the deviation of actual postoperative SE refraction in diopters (D) from preoperative predicted SE refraction, was the primary outcome measure. Results The mean attempted (predicted) SE was - 1.12 D (+/- 0.87). Mean achieved SE was - 0.96 D (+/- 1.04). Mean PE (actual postoperative SE versus predicted preoperative SE) was 0.16 D (+/- 0.69). A total of 9 eyes (45%) were within +/- 0.5 D of the predicted SE, 16 eyes (80%) were within +/- 1.0 D, and all 20 eyes (100%) were within +/- 1.5 D. Conclusion IOL power calculation using the SRK/T formula with optical biometry demonstrates reliable postoperative refractive outcomes in patients undergoing scleral fixation of an IOL (Akreos AO60). Further studies are needed to refine the predictive value of the SRK/T and other formulas for application in scleral fixation of IOLs.
引用
收藏
页码:2125 / 2129
页数:5
相关论文
共 19 条
[1]  
[Anonymous], 2018, USER GROUP LASER INT
[2]   Scleral Fixation of Intraocular Lenses with Gore-Tex Suture Refractive Outcomes and Comparison of Lens Power Formulas [J].
Botsford, Benjamin W. ;
Williams, Andrew M. ;
Conner, Ian P. ;
Martel, Joseph N. ;
Eller, Andrew W. .
OPHTHALMOLOGY RETINA, 2019, 3 (06) :468-472
[3]   Partial coherence interferometry: A novel approach to biometry in cataract surgery [J].
Drexler, W ;
Findl, O ;
Menapace, R ;
Rainer, G ;
Vass, C ;
Hitzenberger, CK ;
Fercher, AF .
AMERICAN JOURNAL OF OPHTHALMOLOGY, 1998, 126 (04) :524-534
[4]   Pseudophakic correction factors for optical biometry [J].
Haigis, W .
GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2001, 239 (08) :589-598
[5]   THE RELATIONSHIP OF VISUAL-ACUITY, REFRACTIVE ERROR, AND PUPIL SIZE AFTER RADIAL KERATOTOMY [J].
HOLLADAY, JT ;
LYNN, MJ ;
WARING, GO ;
GEMMILL, M ;
KEEHN, GC ;
FIELDING, B .
ARCHIVES OF OPHTHALMOLOGY, 1991, 109 (01) :70-76
[6]   Anterior chamber intraocular lens, sutured posterior chamber intraocular lens, or glued intraocular lens: where do we stand? [J].
Holt, Derick G. ;
Young, Jason ;
Stagg, Brian ;
Ambati, Balamurali K. .
CURRENT OPINION IN OPHTHALMOLOGY, 2012, 23 (01) :62-67
[7]   PARS PLANA VITRECTOMY WITH ANTERIOR CHAMBER VERSUS GORE-TEX SUTURED POSTERIOR CHAMBER INTRAOCULAR LENS PLACEMENT Long-Term Outcomes [J].
Khan, M. Ali ;
Gupta, Omesh P. ;
Pendi, Kasim ;
Chiang, Allen ;
Vander, James ;
Regillo, Carl D. ;
Hsu, Jason .
RETINA-THE JOURNAL OF RETINAL AND VITREOUS DISEASES, 2019, 39 (05) :860-866
[8]   COMBINED PARS PLANA VITRECTOMY AND SCLERAL FIXATION OF AN INTRAOCULAR LENS USING GORE-TEX SUTURE [J].
Khan, M. Ali ;
Samara, Wasim A. ;
Gerstenblith, Adam T. ;
Chiang, Allen ;
Mehta, Sonia ;
Garg, Sunir J. ;
Hsu, Jason ;
Gupta, Omesh P. .
RETINA-THE JOURNAL OF RETINAL AND VITREOUS DISEASES, 2018, 38 (07) :1377-1384
[9]   Biometry accuracy using zero-and negative-powered intraocular lenses [J].
MacLaren, RE ;
Sagoo, MS ;
Restori, M ;
Allan, BDS .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2005, 31 (02) :280-290
[10]   Accuracy of Intraocular Lens Calculation Formulas [J].
Melles, Ronald B. ;
Holladay, Jack T. ;
Chang, William J. .
OPHTHALMOLOGY, 2018, 125 (02) :169-178