A reusable ratiometric electrochemical biosensor on the basis of the binding of methylene blue to DNA with alternating AT base sequence for sensitive detection of adenosine

被引:63
作者
Cui, Lin [1 ]
Lu, Mengfei [1 ]
Li, Ying [2 ]
Tang, Bo [1 ]
Zhang, Chun-yang [1 ]
机构
[1] Shandong Normal Univ, Collaborat Innovat Ctr Functionalized Probes Chem, Shandong Prov Key Lab Clean Prod Fine Chem,Minist, Univ Shandong,Coll Chem Chem Engn & Mat Sci,Key L, Jinan 250014, Shandong, Peoples R China
[2] Shenzhen Univ, Hlth Sci Ctr, Sch Med, Shenzhen 518060, Peoples R China
基金
中国国家自然科学基金;
关键词
Electrochemical biosensor; Ratiometric analysis; Aptamer; Adenosine; Sensitivity; Regeneration capability; SIGNAL-ON; ELECTROCHEMILUMINESCENCE RATIOMETRY; FLUORESCENCE APTASENSOR; AMPLIFIED DETECTION; ELECTRON-TRANSFER; FEMTOMOLAR DNA; SENSOR; AMPLIFICATION; APTAMER; REAGENTLESS;
D O I
10.1016/j.bios.2017.11.025
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
We develop a reusable ratiometric electrochemical biosensor on the basis of the binding of methylene blue (MB) to DNA with alternating AT base sequence for sensitive detection of adenosine. We design a strand 1 with MB modified thymine (T) base in the proximal 3' termini as the capture probe for its immobilization on the gold electrode and a 3' termini ferrocene (Fc)-modified aptamer for the recognition of adenosine. The hybridization of strand 1 with the aptamer leads to the formation of a double-stranded DNA (dsDNA) and consequently the away of MB from the electrode surface and the close of Fc to the electrode surface, generating a small value of I-MB/I-FC (I-MB and I-FC are the peak currents of MB and Fc, respectively). In the presence of adenosine, its binding with the aptamer induces the release of Fc from the electrode surface and the close of MB to the electrode surface, generating a large value of I-MB/I-FC. As a result, adenosine may be accurately quantified by the measurement of ratiometric signal (I-MB/I-FC). This ratiometric electrochemical biosensor can be simply fabricated and exhibits high sensitivity with a limit of detection of as low as 90.8 pM and a large dynamic range from 0.1 nM to 100 mu M. Moreover, this biosensor demonstrates good performance with excellent selectivity, regeneration capability, high reliability and good reproducibility, and may become a universal platform for the detection of various biomolecules which can be recognized by aptamers, holding great potential for further applications in biomedical research and clinical diagnosis.
引用
收藏
页码:87 / 93
页数:7
相关论文
共 58 条
[1]   Unmediated by DNA Electron Transfer in Redox-Labeled DNA Duplexes End-Tethered to Gold Electrodes [J].
Abi, Alireza ;
Ferapontova, Elena E. .
JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 2012, 134 (35) :14499-14507
[2]   A new s-adenosylhomocysteine hydrolase-linked method for adenosine detection based on DNA-templated fluorescent Cu/Ag nanoclusters [J].
Ahn, Jun Ki ;
Kim, Hyo Yong ;
Baek, Songyi ;
Park, Hyun Gyu .
BIOSENSORS & BIOELECTRONICS, 2017, 93 :330-334
[3]   DNA-Mediated Electron Transfer in DNA Duplexes Tethered to Gold Electrodes via Phosphorothioated dA Tags [J].
Campos, Rui ;
Kotlyar, Alexander ;
Ferapontova, Elena E. .
LANGMUIR, 2014, 30 (40) :11853-11857
[4]   Ratiometric Electrochemical Sensor for Selective Monitoring of Cadmium Ions Using Biomolecular Recognition [J].
Chai, Xiaolan ;
Zhang, Limin ;
Tian, Yang .
ANALYTICAL CHEMISTRY, 2014, 86 (21) :10668-10673
[5]   Detection of adenosine using surface-enhanced Raman scattering based on structure-switching signaling aptamer [J].
Chen, Ji-Wei ;
Liu, Xue-Ping ;
Feng, Ke-Jun ;
Liang, Yi ;
Jiang, Jian-Hui ;
Shen, Guo-Li ;
Yu, Ru-Qin .
BIOSENSORS & BIOELECTRONICS, 2008, 24 (01) :66-71
[6]   Ratiometric Electrochemical Sensor for Effective and Reliable Detection of Ascorbic Acid in Living Brains [J].
Cheng, Hanjun ;
Wang, Xiaoyu ;
Wei, Hui .
ANALYTICAL CHEMISTRY, 2015, 87 (17) :8889-8895
[7]   A sensitive ratiometric electrochemical biosensor based on DNA four-way junction formation and enzyme-assisted recycling amplification [J].
Cui, Lin ;
Lu, Mengfei ;
Yang, Xiao-yun ;
Tang, Bo ;
Zhang, Chun-yang .
ANALYST, 2017, 142 (09) :1562-1568
[8]   Ratiometric Fluorescent Detection of Phosphate in Aqueous Solution Based on Near Infrared Fluorescent Silver Nanoclusters/Metal-Organic Shell Composite [J].
Dai, Cong ;
Yang, Cheng-Xiong ;
Yan, Xiu-Ping .
ANALYTICAL CHEMISTRY, 2015, 87 (22) :11455-11459
[9]   Maximizing the Signal Gain of Electrochemical-DNA Sensors [J].
Dauphin-Ducharme, Philippe ;
Plaxco, Kevin W. .
ANALYTICAL CHEMISTRY, 2016, 88 (23) :11654-11662
[10]   High-Performance Ratiometric Electrochemical Method Based on the Combination of Signal Probe and Inner Reference Probe in One Hairpin-Structured DNA [J].
Deng, Chunyan ;
Pi, Xiaomei ;
Qian, Pin ;
Chen, Xiaoqing ;
Wu, Wuming ;
Xiang, Juan .
ANALYTICAL CHEMISTRY, 2017, 89 (01) :966-973