Transjugular liver biopsy in liver transplant patients using an 18-gauge automated core biopsy needle

被引:16
作者
Miraglia, Roberto [1 ]
Maruzzelli, Luigi [1 ]
Minervini, Marta Ida [2 ]
Volpes, Riccardo [3 ]
Vizzini, Giovanni [3 ]
Gruttadauria, Salvatore [4 ]
Caruso, Settimo [1 ]
Luca, Angelo [1 ]
Gridelli, Bruno [4 ]
机构
[1] Mediterranean Inst Transplantat & Adv Specialized, Dept Radiol, I-90127 Palermo, Italy
[2] Mediterranean Inst Transplantat & Adv Specialized, Dept Pathol, I-90127 Palermo, Italy
[3] Mediterranean Inst Transplantat & Adv Specialized, Dept Hepatol, I-90127 Palermo, Italy
[4] Mediterranean Inst Transplantat & Adv Specialized, Dept Transplantat Surg, I-90127 Palermo, Italy
关键词
Rejection; Pediatric; Complications; Cirrhosis; Interventional radiology; ACCURATE HISTOLOGICAL INTERPRETATION;
D O I
10.1016/j.ejrad.2010.12.016
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Aim of this retrospective study is to evaluate accuracy and safety of transjugular liver biopsy using an 18-gauge automated core biopsy needle, in patients underwent liver transplantation. 183 consecutively transjugular liver biopsy were performed in 115 liver transplant patients. An 18-gauge automated core needle biopsy was used in all patients. Technical success was achieved in 182 procedures (99.5%). In one patient we were not able to obtain a liver sample. The mean number of passages was 1.43 (range 1-5). Mean number of fragments was 2 (range 1-12). Mean total length of the specimens was 1.7 cm (range 0.5-3.4 cm). The specimen was adequate for diagnosis in 172 (94.5%) cases and suboptimal or inadequate in 10 (4.5%). Suboptimal or inadequate samples were associated with higher number of passages (2.0 vs. 1.4, p < 0.012), higher number of fragments (4.3 vs. 1.9, p < 0.0001) and decreased total length of the specimens (0.99 vs. 1.73, p < 0.03). As only complication one patient (0.5%) had a large perihepatic hematoma requiring blood transfusion. In conclusion using an 18-gauge automated core needle biopsy, in most liver transplant recipients, an accurate diagnosis can be obtained with one or two passages. This is associated with a low risk of complications. (C) 2010 Elsevier Ireland Ltd. All rights reserved.
引用
收藏
页码:E269 / E272
页数:4
相关论文
共 14 条
[1]   Emergency transjugular liver biopsies in post-liver-transplant patients: Technical success and utility [J].
Abujudeh H. ;
Huggins R. ;
Patel A. .
Emergency Radiology, 2004, 10 (5) :268-269
[2]   The value of early transjugular liver biopsy after liver transplantation [J].
Azoulay, D ;
Raccuia, JS ;
Roche, B ;
Reynes, M ;
Bismuth, H .
TRANSPLANTATION, 1996, 61 (03) :406-409
[3]   Current concepts: Liver biopsy. [J].
Bravo, AA ;
Sheth, SG ;
Chopra, S .
NEW ENGLAND JOURNAL OF MEDICINE, 2001, 344 (07) :495-500
[4]   Transjugular liver biopsy in patients with diffuse liver disease: comparison of three cores with one or two cores for accurate histological interpretation [J].
Cholongitas, E. ;
Quaglia, A. ;
Samonakis, D. ;
Mela, M. ;
Patch, D. ;
Dhillon, A. P. ;
Fanshawe, T. R. ;
Burroughs, A. K. .
LIVER INTERNATIONAL, 2007, 27 (05) :646-653
[5]   Transjugular liver biopsy: how good is it for accurate histological interpretation? [J].
Cholongitas, E. ;
Quaglia, A. ;
Samonakis, D. ;
Senzolo, M. ;
Triantos, C. ;
Patch, D. ;
Leandro, G. ;
Dhillon, A. P. ;
Burroughs, A. K. .
GUT, 2006, 55 (12) :1789-1794
[6]   Histological grading and staging in chronic hepatitis:: clinical applications and problems [J].
Hübscher, SG .
JOURNAL OF HEPATOLOGY, 1998, 29 (06) :1015-1022
[7]   Transjugular liver biopsy - Indications, adequacy, quality of specimens, and complications - A systematic review [J].
Kalambokis, George ;
Manousou, Pinelopi ;
Vibhakorn, Shusang ;
Marelli, Laura ;
Cholongitas, Evangelos ;
Senzolo, Marco ;
Patch, David ;
Burroughs, Andrew K. .
JOURNAL OF HEPATOLOGY, 2007, 47 (02) :284-294
[8]   Transjugular liver biopsy in patients with living donor liver transplantation: Comparison with percutaneous biopsy [J].
Kim, Kyung Rae ;
Ko, Gi-Young ;
Sung, Kyu-Bo ;
Yoon, Hyun-Ki ;
Shin, Ji Hoon ;
Song, Ho-Young ;
Ryu, Je-Ho ;
Hwang, Shin ;
Lee, Sung-Gyu ;
Yu, Eunsil .
LIVER TRANSPLANTATION, 2008, 14 (07) :971-979
[9]  
LEE RG, 1994, DIAGNOSTIC LIVER PAT, pCH1
[10]   Transjugular Biopsy Results in the Transplanted Liver: Comparison of Two Surgical Hepatic Venous Anastomotic Configurations in 269 Consecutive Biopsies over a 14-year Period [J].
Miller, Michael J. ;
Smith, Tony P. ;
Kuo, Paul C. ;
Hirasaki, Kenneth K. ;
Suhocki, Paul V. .
JOURNAL OF VASCULAR AND INTERVENTIONAL RADIOLOGY, 2010, 21 (04) :508-514