Ex vivo and in vivo study of Kowa HA-2 applanation tonometer in the measurement of intraocular pressure in cats

被引:2
作者
Ricci, Claudia Lizandra [1 ]
Giuffrida, Rogerio [2 ]
Kanashiro, Glaucia Prada [3 ]
Rufino Belezzi, Hilidia Stephania [4 ]
Bacarin, Carolina de Carvalho [4 ]
Tenorio, Michele Paulo [4 ]
Duran Foglia, Bruna Toledo [4 ]
Andrade, Silvia Franco [5 ,6 ]
机构
[1] Univ Oeste Paulista UNOESTE, Curso Med Vet, Ciencia Anim, Presidente Prudente, SP, Brazil
[2] Univ Oeste Paulista, Curso Med Vet, Dept Bioestat, Presidente Prudente, SP, Brazil
[3] Univ Oeste Paulista, Curso Med Vet, Dept Anestesiol, Presidente Prudente, SP, Brazil
[4] Univ Oeste Paulista, Curso Curso Med Vet, Presidente Prudente, SP, Brazil
[5] Univ Oeste Paulista, Curso Med Vet, Dept Clin Med Pequenos Anim, Presidente Prudente, SP, Brazil
[6] Univ Oeste Paulista, Ciencia Anim, Presidente Prudente, SP, Brazil
来源
SEMINA-CIENCIAS AGRARIAS | 2017年 / 38卷 / 06期
关键词
Applanation tonometer; Ocular manometry; Intraocular pressure; Cats; TONO-PEN XL(R); GLAUCOMA; DOGS;
D O I
10.5433/1679-0359.2017v38n6p3647
中图分类号
S [农业科学];
学科分类号
09 ;
摘要
The objective of this study was to evaluate the use of the Kowa HA-2 applanation tonometer in measuring intraocular pressure (IOP) in cats. Ten healthy eyes were used in an ex vivo study in which the calibration curve for manometry vs. tonometry was determined by artificially raising the IOP in 5 mmHg increments up to 60 mmHg (10-60 mmHg). Both eyes of 10 anesthetized cats were studied in vivo to compare manometry vs. tonometry. In the ambulatory study, 78 healthy eyes, 7 eyes with glaucoma and 20 eyes with uveitis were evaluated by tonometry, which was performed with topical anesthesia and 1% fluorescein eye drops for the formation of fluorescein semicircles. The correlation coefficient (r(2)) between the manometer and the Kowa HA-2 tonometer was 0.993 and the linear regression equation was y = 0.0915x + 0.0878 in the ex-vivo study. In the in vivo study, the IOP values (mean +/- SD, in mmHg) in manometry were 15.6 +/- 1.1(14.0-17.5) and in tonometry were 15.5 +/- 1.2(13.5-17.2), with no significant difference (P > 0.05) between manometry and tonometry. In ambulatory study, using the Kowa HA-2 tonometer, the IOP values (mean +/- SD, in mmHg) were 15.0 +/- 1.5 (11.8-18.3) for the healthy eyes, 38.4 +/- 8.1(29.6-53.7) for glaucomatous eyes and 10.4 +/- 2.0(5.3-12.2) for eyes with uveitis. There was a strong correlation and accuracy between the IOP values with the manometry and the Kowa HA-2 tonometer. In the ambulatory study the IOP values obtained with the tonometer were compatible for animals with healthy eyes and with clinical signs of glaucoma and uveitis. We conclude that the Kowa HA-2 tonometer can be used in the measurement of IOP in cats, since it is a practical and accurate method in this species.
引用
收藏
页码:3647 / 3655
页数:9
相关论文
共 26 条
  • [1] Ex vivo and in vivo study of Kowa HA-2 applanation tonometer in the measurement of intraocular pressure in dogs
    Andrade, Silvia Franco
    de Andrade, Alexandre Lima
    Kanashiro, Glaucia Prada
    Silva, Danielle Alves
    Barbero, Rafael Cabral
    Pereira Kuhn, Jacqueline Marcussi
    da Silva, Andressa Caroline
    [J]. SEMINA-CIENCIAS AGRARIAS, 2016, 37 (02): : 797 - 805
  • [2] Intraocular pressure measurements with the Tono-Pen XL® and Perkins® applanation tonometers in horses and cattle
    Andrade, Silvia Franco
    Palozzi, Rodrigo de Jesus
    Rolim, Rodrigo Duarte
    Cecilio Junqueira, Jose Ricardo
    do Valle, Heloisa Ferreira
    da Silva, Marcelo Kurak
    Maia, Marcelo Augusto
    Zampiere, Rodrigo Augusto
    [J]. CIENCIA RURAL, 2013, 43 (05): : 865 - 870
  • [3] Comparison of intraocular pressure measurements between the Tono-Pen XL® and Perkins® applanation tonometers in dogs and cats
    Andrade, Silvia Franco
    Palozzi, Rodrigo Jesus
    Giuffrida, Rogerio
    de Campos, Renata Juliane
    Santos, Gabriela de Campos
    Fukui, Rosimery Missuzu
    [J]. VETERINARY OPHTHALMOLOGY, 2012, 15 : 14 - 20
  • [4] Evaluation of the Perkins® handheld applanation tonometer in the measurement of intraocular pressure in dogs and cats
    Andrade, Silvia Franco
    Cremonezi, Tatiana
    Miranda Zachi, Cristiane Aparecida
    Lonchiati, Caroline Ferreira
    Amatuzzi, Juliana Dalarrosa
    Sakamoto, Keila Priscilla
    de Arruda Mello, Paulo Augusto
    [J]. VETERINARY OPHTHALMOLOGY, 2009, 12 (05) : 277 - 284
  • [5] Feline uveitis: Diagnosis and treatment
    Colitz, CMH
    [J]. CLINICAL TECHNIQUES IN SMALL ANIMAL PRACTICE, 2005, 20 (02): : 117 - 120
  • [6] Circadian rhythm of intraocular pressure in cats
    Del Sole, Maria J.
    Sande, Pablo H.
    Bernades, Jose M.
    Aba, Marcelo A.
    Rosenstein, Ruth E.
    [J]. VETERINARY OPHTHALMOLOGY, 2007, 10 (03) : 155 - 161
  • [7] New ways to measure intraocular pressure
    ElMallah, Mohammed K.
    Asrani, Sanjay G.
    [J]. CURRENT OPINION IN OPHTHALMOLOGY, 2008, 19 (02) : 122 - 126
  • [8] Featherstone HJ., 2013, Veterinary Ophthalmology, V5th, P533
  • [9] Intraocular pressure measurements obtained as part of a comprehensive geriatric health examination from cats seven years of age or older
    Kroll, MM
    Miller, PE
    Rodan, I
    [J]. JOURNAL OF THE AMERICAN VETERINARY MEDICAL ASSOCIATION, 2001, 219 (10) : 1406 - 1410
  • [10] Morphologic Changes in Trabecular Meshwork after Patterned and Argon Laser Trabeculoplasty in Cats
    Lee, Jong Yeon
    Ha, Seung Yeon
    Paik, Hae Jung
    Kwon, Kun-Young
    Kim, Yong Yeon
    [J]. CURRENT EYE RESEARCH, 2014, 39 (09) : 908 - 916