High Sensitive Electrochemical Quantification of Isoniazid in Biofluids Using Copper Particles Decorated Graphene Oxide Nano Composite

被引:10
作者
Balamurugan, T. S. T. [1 ]
Manibalan, Kesavan [1 ]
Chen, Shen-Ming [1 ]
Balasubramnian, Paramasivam [1 ]
Huang, Sheng-Tung [1 ,2 ]
机构
[1] Natl Taipei Univ Technol, Dept Chem Engn & Biotechnol, 1,Sect 3,Chung Hsiao East Rd, Taipei 106, Taiwan
[2] Natl Taipei Univ Technol, Inst Biochem & Biomed Engn, 1,Sect 3,Chung Hsiao East Rd, Taipei 106, Taiwan
关键词
Hepatotoxic drugs; Isoniazid; Graphene oxide nanocomposite; Electrocatalysis; Bio-fluid analysis; DRUG-INDUCED HEPATOTOXICITY; VOLTAMMETRIC BEHAVIOR; MODIFIED ELECTRODE; OXIDATION; GLUCOSE; SENSOR; NANOPARTICLES; MECHANISMS; RIFAMPICIN; HYDRAZINE;
D O I
10.20964/2017.10.44
中图分类号
O646 [电化学、电解、磁化学];
学科分类号
081704 ;
摘要
The excessive consumption and harming side effects of chemical antibiotics and NSAIDs are lead to the necessity of a simple analytical tool for high sensitive, quantitative detection of hepatotoxic drugs in human body fluids. In this work, we report an electrochemical sensor constructed by the facile electrochemical deposition of copper micro particles over graphene oxide nanosheets modified glassy carbon electrode and their potential application towards quantitative detection of isoniazid (isonicotinylhydrazide INH) (hepatotoxic drug) in bio fluids. The constructed Cu/GO/GCE electrode was further characterized by SEM, EDX, and Raman spectroscopy. As constructed electrode displayed excellent synergy and enhanced electrocatalytic activity towards INH. The described sensing platform of INH exhibits low limit of detection (LOD) 23.4nM and wide linear range 0.15 mu M - 500 mu M with high sensitivity of 1.2394 mu A mu M-1 cm(-2). The practical feasibility of the Cu/GO/GCE electrode is demonstrated in urine, and human serum sample with direct spiking of INH and achieved good recoveries.
引用
收藏
页码:9150 / 9160
页数:11
相关论文
共 40 条
[1]  
Atta NF, 2011, INT J ELECTROCHEM SC, V6, P5097
[2]   Electrochemical Determination of Isoniazid Using Gallic Acid Supported Reduced Graphene Oxide [J].
Balasubramanian, Paramasivam ;
Thirumalraj, Balamurugan ;
Chen, Shen-Ming ;
Barathi, Palani .
JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 2017, 164 (07) :II503-II508
[3]   Current perspectives on pain upon injection of drugs [J].
Brazeau, GA ;
Cooper, B ;
Svetic, KA ;
Smith, CL ;
Gupta, P .
JOURNAL OF PHARMACEUTICAL SCIENCES, 1998, 87 (06) :667-677
[4]   Validation of a RP-LC method for the simultaneous determination of isoniazid, pyrazinamide and rifampicin in a pharmaceutical formulation [J].
Calleri, E ;
De Lorenzi, E ;
Furlanetto, S ;
Massolini, G ;
Caccialanza, G .
JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2002, 29 (06) :1089-1096
[5]   Electrochemical determination of selected antihypertensive and antituberculosis drugs at a tyrosine-modified electrode [J].
Cheemalapati, Srikanth ;
Devadas, Balamurugan ;
Chen, Shen-Ming ;
Ali, M. Ajmal ;
Al-Hemaid, Fahad M. A. .
ANALYTICAL METHODS, 2014, 6 (17) :6774-6782
[6]  
Cheemalapati S, 2013, INT J ELECTROCHEM SC, V8, P3953
[7]   The chemistry of graphene oxide [J].
Dreyer, Daniel R. ;
Park, Sungjin ;
Bielawski, Christopher W. ;
Ruoff, Rodney S. .
CHEMICAL SOCIETY REVIEWS, 2010, 39 (01) :228-240
[8]   Development of Cu2O/Carbon Vulcan XC-72 as non-enzymatic sensor for glucose determination [J].
El Khatib, K. M. ;
Hameed, R. M. Abdel .
BIOSENSORS & BIOELECTRONICS, 2011, 26 (08) :3542-3548
[9]   Self-assembled monolayers of L-cysteine on palladium electrodes [J].
Feliciano-Ramos, Ileana ;
Caban-Acevedo, Miguel ;
Scibioh, M. Aulice ;
Cabrera, Carlos R. .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2010, 650 (01) :98-104
[10]   Electrochemical behavior of the antituberculosis drug isoniazid and its square-wave adsorptive stripping voltammetric estimation in bulk form, tablets and biological fluids at a mercury electrode [J].
Ghoneim, MM ;
El-Baradie, KY ;
Tawfik, A .
JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2003, 33 (04) :673-685