Successful Surgical Repair of Acute Quadriceps Tendon Rupture Utilizing Cortical Button Fixation: A Case Report

被引:0
|
作者
Bae, Andrew S. [1 ]
Collins, Devin W. [1 ]
Jardaly, Achraf H. [2 ]
Fernicola, Patrick J. [1 ,2 ]
机构
[1] Jack Hughston Mem Hosp, Dept Orthopaed Surg, Phenix City, AL 36867 USA
[2] Hughston Clin, Dept Sports Med, Columbus, GA 31909 USA
关键词
Orthopedic Procedures; Quadriceps Muscle; Tendons;
D O I
10.12659/AJCR.934238
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objective: Unusual setting of medical care Background: Timely diagnosis and surgical treatment are often needed to restore function of the extensor mechanism after rupture of the quadriceps tendon. Several techniques for quadriceps tendon repair have been reported, including suture anchors and bone tunnels. Cortical button fixation, or the use of an adjustable cortical fixation device, is a local and biomechanically strong internal brace technique used to treat ligament and tendon injuries. This report is of a 69-year-old man who experienced a quadriceps tendon rupture while golfing and underwent a successful surgical repair using cortical button fixation. Case Report: A 69-year-old man sustained an injury after slipping while golfing. He had immediate left knee pain and inability to bear weight. Radiographs demonstrated patella baja with an acute superior pole avulsion fracture of the patella, consistent with rupture of the quadriceps tendon. Surgical repair was discussed. Technique: After soft tissue debridement, the quadriceps tendon was debrided from the frayed and edematous edges. Two Krackowtype stitches were placed with #2 Fibertape and passed through 2 cortical buttons. Two bone tunnels were drilled from the superior to the inferior poles of the patella, bicortically. The cortical button was passed and appropriately tensioned. Conclusions: Although acute quadriceps tendon rupture is commonly treated with transosseous suture repair and suture anchor repair, this report demonstrates that cortical button fixation was a successful procedure with strong biomechanical properties, resulting in the early return of function and range of motion.
引用
收藏
页数:5
相关论文
共 4 条
  • [1] Simultaneous Bilateral Quadriceps Femoris Tendon Rupture: Case report
    Gunaydin, Pamukcu G.
    Demircan, S.
    Oz, T.
    Otal, Y.
    JOURNAL OF EMERGENCY MEDICINE CASE REPORTS, 2021, 12 (04): : 97 - 99
  • [2] Bilateral simultaneous distal biceps tendon rupture repair with both cortical button and interference screw
    Tudisco, Cosimo
    Di Marcantonio, Arianna
    Cosseddu, Tomaso
    De Sanctis, Edoardo Giovannetti
    MINERVA ORTHOPEDICS, 2024, 75 (02): : 171 - 175
  • [3] The Outcome of Acute Quadriceps Tendon Rupture Managed with Primary Repair and Mersilene Tape Augmentation
    Akgun, Rahmi Can
    Tandogan, N. Reha
    Sahin, Orcun
    TURKIYE KLINIKLERI TIP BILIMLERI DERGISI, 2009, 29 (02): : 438 - 444
  • [4] Early, Bilateral Re-Rupture of Quadriceps Tendon After Previous Bone-Anchor Repair for Simultaneous, Low-Energy, Bilateral Quadriceps Rupture: A Case Report and Literature Review
    Panagopoulos, Andreas
    Kalavrytinos, Dimitrios
    Giannatos, Vasileios
    Tatani, Irini
    Kouzelis, Antonis
    Kokkalis, Zinon
    AMERICAN JOURNAL OF CASE REPORTS, 2021, 22