Hyperpolarized 129Xe MR Imaging with Balanced Steady-state Free Precession in Spontaneously Breathing Mouse Lungs

被引:6
作者
Imai, Fumito [1 ]
Kashiwagi, Ryosuke [1 ]
Imai, Hirohiko [1 ]
Iguchi, Satoshi [1 ]
Kimura, Atsuomi [1 ]
Fujiwara, Hideaki [1 ]
机构
[1] Osaka Univ, Grad Sch Med, Div Med Phys & Engn, Area Med Technol & Sci,Course Hlth Sci, Suita, Osaka 5650871, Japan
关键词
balanced steady-state free precession; hyperpolarized Xe-129; MR imaging; mouse lungs; spontaneous breathing; MAGNETIC-RESONANCE; HE-3; VENTILATION; GAS;
D O I
10.2463/mrms.10.33
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: We investigated the characteristics of hyperpolarized (HP) Xe-129 magnetic resonance (MR) imaging obtained from balanced steady-state free precession (SSFP) measurement of mouse lungs, especially under spontaneous breathing, and compared the results with those obtained using traditional spoiled gradient echo (SPGR) method, focusing on improved signal-to-noise ratio (SNR) and reduced total acquisition time. Methods: We calculated magnetization response of the HP Xe-129 gas for the balanced SSFP sequence under spontaneous breathing to derive optimal conditions for the imaging experiment. We then placed an anesthetized mouse in the magnet (9.4T) supplied with oxygen gas and a mixture of HP Xe-129 gas supplied from a continuous-flow hyperpolarizing system. We obtained an axial plane image of the lung through balanced SSFP and SPGR sequences, changing the various magnetic resonance (MR) imaging parameters, and measured the SNR of these images. Results: We demonstrated the clear dependence of image intensity on flip angle and number of shots. The SNR was higher in balanced SSFP than in SPGR and 2.3-fold higher compared at each maximum. In contrast, total acquisition time in balanced SSFP was shortened to about one-eighth that of SPGR using a one-shot acquisition mode. Conclusion: In HP Xe-129 MR imaging of the lung of a spontaneously breathing mouse, balanced SSFP sequence with multi-shot and centric order acquisition provides higher SNR in a shorter acquisition time than SPGR.
引用
收藏
页码:33 / 40
页数:8
相关论文
共 50 条
[31]   Phase imaging with multiple phase-cycled balanced steady-state free precession at 9.4T [J].
Kim, Jae-Woong ;
Kim, Seong-Gi ;
Park, Sung-Hong .
NMR IN BIOMEDICINE, 2017, 30 (06)
[32]   Free-breathing half-radial dual-echo balanced steady-state free precession thoracic imaging with wobbling Archimedean spiral pole trajectories [J].
Bieri, Oliver ;
Pusterla, Orso ;
Bauman, Grzegorz .
ZEITSCHRIFT FUR MEDIZINISCHE PHYSIK, 2023, 33 (02) :220-229
[33]   Analytical Characterization of RF Phase-Cycled Balanced Steady-State Free Precession [J].
Lauzon, M. Louis ;
Frayne, Richard .
CONCEPTS IN MAGNETIC RESONANCE PART A, 2009, 34A (03) :133-143
[34]   Validation of Noninvasive Morphological and Diffusion Imaging in Mouse Emphysema by Micro-Computed Tomography and Hyperpolarized 129Xe Magnetic Resonance Imaging [J].
Tetsumoto, Satoshi ;
Takeda, Yoshito ;
Imai, Hirohiko ;
Kimura, Atsuomi ;
Jin, Yingji ;
Nakanishi, Kaori ;
Maeda, Yohei ;
Kuhara, Hanako ;
Tsujino, Kazuyuki ;
Iwasaki, Takeo ;
Shigeta, Hiroshi ;
Kondo, Yasushi ;
Ito, Mari ;
Minami, Toshiyuki ;
Hirata, Haruhiko ;
Takahashi, Ryo ;
Kohmo, Satoshi ;
Nagatomo, Izumi ;
Inoue, Koji ;
Kida, Hiroshi ;
Kijima, Takashi ;
Tachibana, Isao ;
Maeda, Norikazu ;
Funahashi, Toru ;
Shimomura, Iichiro ;
Fujiwara, Hideaki ;
Kumanogoh, Atsushi .
AMERICAN JOURNAL OF RESPIRATORY CELL AND MOLECULAR BIOLOGY, 2013, 49 (04) :592-600
[35]   Comparison of 3D UTE free-breathing lung MRI with hyperpolarized 129Xe MRI in pediatric cystic fibrosis [J].
Munidasa, Samal ;
Zanette, Brandon ;
Dumas, Marie-Pier ;
Wee, Wallace ;
Braganza, Sharon ;
Li, Daniel ;
Ratjen, Felix ;
Santyr, Giles .
MAGNETIC RESONANCE IN MEDICINE, 2025, 93 (02) :775-787
[36]   Balanced Steady-State Free Precession Cine MR Imaging in the Presence of Cardiac Devices: Value of Interleaved Radial Linear Combination Acquisition With Partial Dephasing [J].
Xiang, Jie ;
Lamy, Jerome ;
Lampert, Rachel ;
Peters, Dana C. .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 2023, 58 (03) :782-791
[37]   3D non-contrast-enhanced MR angiography with balanced steady-state free precession Dixon method [J].
Stafford, Randall B. ;
Sabati, Mohammad ;
Mahallati, Houman ;
Frayne, Richard .
MAGNETIC RESONANCE IN MEDICINE, 2008, 59 (02) :430-433
[38]   3-DIMENSIONAL MR OF THE INNER-EAR WITH STEADY-STATE FREE PRECESSION [J].
GUIRADO, CR ;
MARTINEZ, P ;
ROIG, R ;
MIROSA, F ;
SALMERON, J ;
FLORENSA, F ;
ROGER, M ;
BARRAGAN, Y .
AMERICAN JOURNAL OF NEURORADIOLOGY, 1995, 16 (09) :1909-1913
[39]   Clinical Applications of Cine Balanced Steady-State Free Precession MRI for the Evaluation of the Subarachnoid Spaces [J].
A.E. Li ;
M.D. Wilkinson ;
K.M. McGrillen ;
M.A. Stoodley ;
J.S. Magnussen .
Clinical Neuroradiology, 2015, 25 :349-360
[40]   Artificial neural network for suppression of banding artifacts in balanced steady-state free precession MRI [J].
Kim, Ki Hwan ;
Park, Sung-Hong .
MAGNETIC RESONANCE IMAGING, 2017, 37 :139-146