Hyperpolarized 129Xe MR Imaging with Balanced Steady-state Free Precession in Spontaneously Breathing Mouse Lungs

被引:6
作者
Imai, Fumito [1 ]
Kashiwagi, Ryosuke [1 ]
Imai, Hirohiko [1 ]
Iguchi, Satoshi [1 ]
Kimura, Atsuomi [1 ]
Fujiwara, Hideaki [1 ]
机构
[1] Osaka Univ, Grad Sch Med, Div Med Phys & Engn, Area Med Technol & Sci,Course Hlth Sci, Suita, Osaka 5650871, Japan
关键词
balanced steady-state free precession; hyperpolarized Xe-129; MR imaging; mouse lungs; spontaneous breathing; MAGNETIC-RESONANCE; HE-3; VENTILATION; GAS;
D O I
10.2463/mrms.10.33
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: We investigated the characteristics of hyperpolarized (HP) Xe-129 magnetic resonance (MR) imaging obtained from balanced steady-state free precession (SSFP) measurement of mouse lungs, especially under spontaneous breathing, and compared the results with those obtained using traditional spoiled gradient echo (SPGR) method, focusing on improved signal-to-noise ratio (SNR) and reduced total acquisition time. Methods: We calculated magnetization response of the HP Xe-129 gas for the balanced SSFP sequence under spontaneous breathing to derive optimal conditions for the imaging experiment. We then placed an anesthetized mouse in the magnet (9.4T) supplied with oxygen gas and a mixture of HP Xe-129 gas supplied from a continuous-flow hyperpolarizing system. We obtained an axial plane image of the lung through balanced SSFP and SPGR sequences, changing the various magnetic resonance (MR) imaging parameters, and measured the SNR of these images. Results: We demonstrated the clear dependence of image intensity on flip angle and number of shots. The SNR was higher in balanced SSFP than in SPGR and 2.3-fold higher compared at each maximum. In contrast, total acquisition time in balanced SSFP was shortened to about one-eighth that of SPGR using a one-shot acquisition mode. Conclusion: In HP Xe-129 MR imaging of the lung of a spontaneously breathing mouse, balanced SSFP sequence with multi-shot and centric order acquisition provides higher SNR in a shorter acquisition time than SPGR.
引用
收藏
页码:33 / 40
页数:8
相关论文
共 50 条
  • [21] STEADY-STATE FREE PRECESSION IMAGING OF THE INNER-EAR
    STILLMAN, AE
    REMLEY, K
    LOES, DJ
    HU, XP
    LATCHAW, RE
    AMERICAN JOURNAL OF NEURORADIOLOGY, 1994, 15 (02) : 348 - 350
  • [22] Arterial spin labeled perfusion imaging with balanced steady-state free precession readout and radial sampling
    Han, Paul Kyu
    Marin, Thibault
    Zhuo, Yue
    Ouyang, Jinsong
    El Fakhri, Georges
    Ma, Chao
    MAGNETIC RESONANCE IMAGING, 2023, 102 : 126 - 132
  • [23] 6 Improved dark blood imaging of the heart using radial balanced steady-state free precession
    Edelman, Robert R.
    Botelho, Marcos
    Pursnani, Amit
    Giri, Shivraman
    Koktzoglou, Ioannis
    JOURNAL OF CARDIOVASCULAR MAGNETIC RESONANCE, 2016, 18
  • [24] Utility of Balanced Steady-State Free Precession MR Venography in the Diagnosis of Lower Extremity Deep Venous Thrombosis
    Lindquist, Chris M.
    Karlicki, Fern
    Lawrence, Patrick
    Strzelczyk, Jacek
    Pawlyshyn, Neal
    Kirkpatrick, Iain D. C.
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2010, 194 (05) : 1357 - 1364
  • [25] Use of simulated annealing for the design of multiple repetition time balanced steady-state free precession imaging
    Lee, Kuan J.
    Lee, Hsu-Lei
    Hennig, Juergen
    Leupold, Jochen
    MAGNETIC RESONANCE IN MEDICINE, 2012, 68 (01) : 220 - 226
  • [26] In Vivo MR Imaging of Pulmonary Perfusion and Gas Exchange in Rats via Continuous Extracorporeal Infusion of Hyperpolarized 129Xe
    Cleveland, Zackary I.
    Moeller, Harald E.
    Hedlund, Laurence W.
    Nouls, John C.
    Freeman, Matthew S.
    Qi, Yi
    Driehuys, Bastiaan
    PLOS ONE, 2012, 7 (02):
  • [27] Off-resonance-dependent slice profile effects in balanced steady-state free precession imaging
    Staehle, F.
    Leupold, J.
    Hennig, J.
    Markl, M.
    MAGNETIC RESONANCE IN MEDICINE, 2008, 59 (05) : 1197 - 1202
  • [28] Whole-brain perfusion imaging with balanced steady-state free precession arterial spin labeling
    Han, Paul Kyu
    Ye, Jong Chul
    Kim, Eung Yeop
    Choi, Seung Hong
    Park, Sung-Hong
    NMR IN BIOMEDICINE, 2016, 29 (03) : 264 - 274
  • [29] An asymmetrical whole-body birdcage RF coil without RF shield for hyperpolarized 129Xe lung MR imaging at 1.5 T
    Puddu, Claudio
    Rao, Madhwesha
    Xu, Xiaojun
    Deppe, Martin H.
    Collier, Guilhem
    Maunder, Adam
    Chan, Ho-Fung
    De Zanche, Nicola
    Robb, Fraser
    Wild, Jim M.
    MAGNETIC RESONANCE IN MEDICINE, 2021, 86 (06) : 3373 - 3381
  • [30] Phase imaging with multiple phase-cycled balanced steady-state free precession at 9.4T
    Kim, Jae-Woong
    Kim, Seong-Gi
    Park, Sung-Hong
    NMR IN BIOMEDICINE, 2017, 30 (06)