Hyperpolarized 129Xe MR Imaging with Balanced Steady-state Free Precession in Spontaneously Breathing Mouse Lungs

被引:6
|
作者
Imai, Fumito [1 ]
Kashiwagi, Ryosuke [1 ]
Imai, Hirohiko [1 ]
Iguchi, Satoshi [1 ]
Kimura, Atsuomi [1 ]
Fujiwara, Hideaki [1 ]
机构
[1] Osaka Univ, Grad Sch Med, Div Med Phys & Engn, Area Med Technol & Sci,Course Hlth Sci, Suita, Osaka 5650871, Japan
关键词
balanced steady-state free precession; hyperpolarized Xe-129; MR imaging; mouse lungs; spontaneous breathing; MAGNETIC-RESONANCE; HE-3; VENTILATION; GAS;
D O I
10.2463/mrms.10.33
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: We investigated the characteristics of hyperpolarized (HP) Xe-129 magnetic resonance (MR) imaging obtained from balanced steady-state free precession (SSFP) measurement of mouse lungs, especially under spontaneous breathing, and compared the results with those obtained using traditional spoiled gradient echo (SPGR) method, focusing on improved signal-to-noise ratio (SNR) and reduced total acquisition time. Methods: We calculated magnetization response of the HP Xe-129 gas for the balanced SSFP sequence under spontaneous breathing to derive optimal conditions for the imaging experiment. We then placed an anesthetized mouse in the magnet (9.4T) supplied with oxygen gas and a mixture of HP Xe-129 gas supplied from a continuous-flow hyperpolarizing system. We obtained an axial plane image of the lung through balanced SSFP and SPGR sequences, changing the various magnetic resonance (MR) imaging parameters, and measured the SNR of these images. Results: We demonstrated the clear dependence of image intensity on flip angle and number of shots. The SNR was higher in balanced SSFP than in SPGR and 2.3-fold higher compared at each maximum. In contrast, total acquisition time in balanced SSFP was shortened to about one-eighth that of SPGR using a one-shot acquisition mode. Conclusion: In HP Xe-129 MR imaging of the lung of a spontaneously breathing mouse, balanced SSFP sequence with multi-shot and centric order acquisition provides higher SNR in a shorter acquisition time than SPGR.
引用
收藏
页码:33 / 40
页数:8
相关论文
共 50 条
  • [1] Multiple Breath Washout of Hyperpolarized 129Xe and 3He in Human Lungs With Three-Dimensional Balanced Steady-State Free-Precession Imaging
    Horn, Felix C.
    Rao, Madhwesha
    Stewart, Neil J.
    Wild, Jim M.
    MAGNETIC RESONANCE IN MEDICINE, 2017, 77 (06) : 2288 - 2295
  • [2] Hyperpolarized 129Xe lung MRI in spontaneously breathing mice with respiratory gated fast imaging and its application to pulmonary functional imaging
    Imai, Hirohiko
    Kimura, Atsuomi
    Hori, Yuki
    Iguchi, Satoshi
    Kitao, Takuya
    Okubo, Emi
    Ito, Tsuyoshi
    Matsuzaki, Toshio
    Fujiwara, Hideaki
    NMR IN BIOMEDICINE, 2011, 24 (10) : 1343 - 1352
  • [3] Regional fractional ventilation mapping in spontaneously breathing mice using hyperpolarized 129Xe MRI
    Imai, Hirohiko
    Matsumoto, Hironobu
    Miyakoshi, Erika
    Okumura, Shintaro
    Fujiwara, Hideaki
    Kimura, Atsuomi
    NMR IN BIOMEDICINE, 2015, 28 (01) : 24 - 29
  • [4] Hyperpolarized 129Xe MR Imaging of Alveolar Gas Uptake in Humans
    Cleveland, Zackary I.
    Cofer, Gary P.
    Metz, Gregory
    Beaver, Denise
    Nouls, John
    Kaushik, S. Sivaram
    Kraft, Monica
    Wolber, Jan
    Kelly, Kevin T.
    McAdams, H. Page
    Driehuys, Bastiaan
    PLOS ONE, 2010, 5 (08):
  • [5] Chronic Obstructive Pulmonary Disease: Lobar Analysis with Hyperpolarized 129Xe MR Imaging
    Matin, Tahreema N.
    Rahman, Najib
    Nickol, Annabel H.
    Chen, Mitchell
    Xu, Xiaojun
    Stewart, Neil J.
    Doel, Tom
    Grau, Vicente
    Wild, James M.
    Gleeson, Fergus V.
    RADIOLOGY, 2017, 282 (03) : 857 - 868
  • [6] Pure balanced steady-state free precession imaging (pure bSSFP)
    Schaeper, Jessica
    Bauman, Grzegorz
    Ganter, Carl
    Bieri, Oliver
    MAGNETIC RESONANCE IN MEDICINE, 2022, 87 (04) : 1886 - 1893
  • [7] Hyperpolarized 129Xe Time-of-Flight MR Imaging of Perfusion and Brain Function
    Shepelytskyi, Yurii
    Hane, Francis T.
    Grynko, Vira
    Li, Tao
    Hassan, Ayman
    Albert, Mitchell S.
    DIAGNOSTICS, 2020, 10 (09)
  • [8] Pulmonary Perfusion and Xenon Gas Exchange in Rats: MR Imaging with Intravenous Injection of Hyperpolarized 129Xe
    Driehuys, Bastiaan
    Moeller, Harald E.
    Cleveland, Zackary I.
    Pollaro, James
    Hedlund, Laurence W.
    RADIOLOGY, 2009, 252 (02) : 386 - 393
  • [9] Quantification of Ventilation and Gas Uptake in Free-Breathing Mice With Hyperpolarized 129Xe MRI
    Loza, Luis A.
    Kadlecek, Stephen J.
    Pourfathi, Mehrdad
    Hamedani, Hooman
    Duncan, Ian F.
    Ruppert, Kai
    Rizi, Rahim R.
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 2019, 38 (09) : 2081 - 2091
  • [10] Direct imaging of hyperpolarized 129Xe alveolar gas uptake in a mouse model of emphysema
    Iguchi, Satoshi
    Imai, Hirohiko
    Hori, Yuki
    Nakajima, Junichi
    Kimura, Atsuomi
    Fujiwara, Hideaki
    MAGNETIC RESONANCE IN MEDICINE, 2013, 70 (01) : 207 - 215