Influence of Rotor Position in FRA Response for Detection of Insulation Failures in Salient-Pole Synchronous Machines

被引:27
|
作者
Platero, Carlos A. [1 ]
Blazquez, F. [1 ]
Frias, Pablo [2 ]
Ramirez, Dionisio [1 ]
机构
[1] Univ Politecn Madrid, Dept Elect Engn, Escuela Tecn Super Ingn Ind, E-28006 Madrid, Spain
[2] Univ Pontificia Comillas Madrid, Dept Elect & Power Syst, Madrid, Spain
关键词
Fault diagnosis; fault location; frequency response analysis; synchronous machines; FAULT-DETECTION TECHNIQUE; POWER TRANSFORMERS; WINDING MOVEMENT; FREQUENCY;
D O I
10.1109/TEC.2011.2106214
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
Frequency response analysis (FRA) is a very common test for the diagnosis of power transformers. This paper presents some relevant results on the application of FRA to the diagnosis of rotating machines. First, a reference rotor position for obtaining the reference FRA response of a rotating machine is proposed. Then, FRA with the proposed rotor position is used to identify faults in the stator of the machine. This paper studies turn-to-turn and ground faults in the stator for different fault resistance values. Several laboratory tests demonstrate the applicability and value of the use of FRA in the diagnosis of rotating machines.
引用
收藏
页码:671 / 676
页数:6
相关论文
共 19 条
  • [1] Inductanceless Model of Salient-Pole Synchronous Machines
    Sobczyk, T. J.
    2008 INTERNATIONAL SYMPOSIUM ON POWER ELECTRONICS, ELECTRICAL DRIVES, AUTOMATION AND MOTION, VOLS 1-3, 2008, : 620 - 625
  • [2] Off-Line Detection of Static Eccentricity in Salient-Pole Synchronous Machines
    Gyftakis, K. N.
    Platero, C. A.
    Bernal, S.
    2018 XIII INTERNATIONAL CONFERENCE ON ELECTRICAL MACHINES (ICEM), 2018, : 1919 - 1924
  • [3] Standstill frequency-response methods and salient-pole synchronous machines
    Saunders, RM
    IEEE TRANSACTIONS ON ENERGY CONVERSION, 1999, 14 (04) : 1033 - 1037
  • [4] Modeling of Salient-Pole Synchronous Machines Assisted by Permanent Magnets
    Yamazaki, Katsumi
    Tamiya, Syuichi
    Shima, Kazuo
    Fukami, Tadashi
    Shirai, Keisuke
    IEEE TRANSACTIONS ON MAGNETICS, 2011, 47 (10) : 3028 - 3031
  • [5] Improving the starting performance of large salient-pole synchronous machines
    Karmaker, H
    Mi, CT
    IEEE TRANSACTIONS ON MAGNETICS, 2004, 40 (04) : 1920 - 1928
  • [6] Simulation and detection of dynamic air-gap eccentricity in salient-pole synchronous machines
    Toliyat, HA
    Al-Nuaim, NA
    IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 1999, 35 (01) : 86 - 93
  • [7] Output Maximization of Salient-Pole Synchronous Machines by Using Additional Permanent Magnets
    Yamazaki, Katsumi
    Tamiya, Shuichi
    Shima, Kazuo
    Fukami, Tadashi
    Sato, Masato
    2012 15TH INTERNATIONAL CONFERENCE ON ELECTRICAL MACHINES AND SYSTEMS (ICEMS 2012), 2012,
  • [8] Output Maximization of Salient-Pole Synchronous Machines by Using Additional Permanent Magnets
    Yamazaki, Katsumi
    Tamiya, Shuichi
    Shima, Kazuo
    Fukami, Tadashi
    Sato, Masato
    IEEJ JOURNAL OF INDUSTRY APPLICATIONS, 2013, 2 (06) : 276 - 282
  • [9] A simple explicit method of representing magnetic saturation of salient-pole synchronous machines in both rotor axes using Matlab-Simulink
    Wang, Liwei
    Jatskevich, Juri
    Ozog, Nathan
    Davoudi, Ali
    2007 CANADIAN CONFERENCE ON ELECTRICAL AND COMPUTER ENGINEERING, VOLS 1-3, 2007, : 256 - 259
  • [10] A standstill frequency response method for large salient pole synchronous machines
    da Costa Bortini, E
    Jardini, JA
    IEEE TRANSACTIONS ON ENERGY CONVERSION, 2004, 19 (04) : 687 - 691