Influence of Rotor Position in FRA Response for Detection of Insulation Failures in Salient-Pole Synchronous Machines

被引:27
|
作者
Platero, Carlos A. [1 ]
Blazquez, F. [1 ]
Frias, Pablo [2 ]
Ramirez, Dionisio [1 ]
机构
[1] Univ Politecn Madrid, Dept Elect Engn, Escuela Tecn Super Ingn Ind, E-28006 Madrid, Spain
[2] Univ Pontificia Comillas Madrid, Dept Elect & Power Syst, Madrid, Spain
关键词
Fault diagnosis; fault location; frequency response analysis; synchronous machines; FAULT-DETECTION TECHNIQUE; POWER TRANSFORMERS; WINDING MOVEMENT; FREQUENCY;
D O I
10.1109/TEC.2011.2106214
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
Frequency response analysis (FRA) is a very common test for the diagnosis of power transformers. This paper presents some relevant results on the application of FRA to the diagnosis of rotating machines. First, a reference rotor position for obtaining the reference FRA response of a rotating machine is proposed. Then, FRA with the proposed rotor position is used to identify faults in the stator of the machine. This paper studies turn-to-turn and ground faults in the stator for different fault resistance values. Several laboratory tests demonstrate the applicability and value of the use of FRA in the diagnosis of rotating machines.
引用
收藏
页码:671 / 676
页数:6
相关论文
共 50 条
  • [1] Optimisation of Salient-Pole Rotor for Synchronous Generators
    Bell, A. E.
    Anpalahan, P.
    2018 XIII INTERNATIONAL CONFERENCE ON ELECTRICAL MACHINES (ICEM), 2018, : 339 - 344
  • [2] Inductanceless Model of Salient-Pole Synchronous Machines
    Sobczyk, T. J.
    2008 INTERNATIONAL SYMPOSIUM ON POWER ELECTRONICS, ELECTRICAL DRIVES, AUTOMATION AND MOTION, VOLS 1-3, 2008, : 620 - 625
  • [3] Analytical calculations of electromagnetic quantities for wound rotor salient-pole synchronous machines
    Delirani, Zohreh
    Rahideh, Akbar
    Mardaneh, Mohammad
    COMPEL-THE INTERNATIONAL JOURNAL FOR COMPUTATION AND MATHEMATICS IN ELECTRICAL AND ELECTRONIC ENGINEERING, 2021, 40 (03) : 325 - 357
  • [4] Enhanced Rotor Position/Speed Observer for Sensorless Control of Salient-Pole Permanent-Magnet Synchronous Machines
    Zhao, Yue
    Qiao, Wei
    2015 IEEE ENERGY CONVERSION CONGRESS AND EXPOSITION (ECCE), 2015, : 860 - 866
  • [5] Standstill Frequency Response testing and modeling of salient-pole synchronous machines
    Park, D.Y.
    Karmaker, H.C.
    Dawson, G.E.
    Eastham, A.R.
    IEEE Transactions on Energy Conversion, 1998, 13 (03): : 230 - 236
  • [6] Standstill frequency-response methods and salient-pole synchronous machines
    Saunders, RM
    IEEE TRANSACTIONS ON ENERGY CONVERSION, 1999, 14 (04) : 1033 - 1037
  • [7] Standstill frequency-response methods and salient-pole synchronous machines
    IEEE
    不详
    不详
    IEEE Trans Energy Convers, 4 (1033-1037):
  • [8] APPRAISAL OF SATURATION IN SALIENT-POLE SYNCHRONOUS MACHINES.
    Abdel-Hamid, Radwan H.
    Morsi, M.F.
    Fahmi, M.A.
    Modelling, Measurement and Control A, 1987, 10 (04): : 17 - 28
  • [9] MODELING SATURATION OF LAMINATED SALIENT-POLE SYNCHRONOUS MACHINES
    ABDELHALIM, MA
    MANNING, CD
    IEE PROCEEDINGS-B ELECTRIC POWER APPLICATIONS, 1987, 134 (04): : 215 - 223
  • [10] Saturation Independent Detection of Dynamic Eccentricity Fault in Salient-Pole Synchronous Machines
    Ilamparithi, T.
    Nandi, Subhasis
    2013 9TH IEEE INTERNATIONAL SYMPOSIUM ON DIAGNOSTICS FOR ELECTRIC MACHINES, POWER ELECTRONICS AND DRIVES (SDEMPED), 2013, : 336 - 341