Analytical method development for the determination of emerging contaminants in water using supercritical-fluid chromatography coupled with diode-array detection

被引:18
作者
del Carmen Salvatierra-Stamp, Vilma [1 ]
Ceballos-Magana, Silvia G. [2 ]
Gonzalez, Jorge [1 ]
Ibarra-Galvan, Valentin [1 ]
Muniz-Valencia, Roberto [1 ]
机构
[1] Univ Colima, Fac Ciencias Quim, Coquimatlan 28400, Colima, Mexico
[2] Univ Colima, Fac Ciencias, Colima 28045, Mexico
关键词
Emerging contaminants; Supercritical-fluid chromatography; Solid-phase extraction; Environmental water samples; PERFORMANCE LIQUID-CHROMATOGRAPHY; SOLID-PHASE EXTRACTION; TANDEM MASS-SPECTROMETRY; WASTE-WATER; SAMPLES;
D O I
10.1007/s00216-015-8581-x
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
An analytical method using supercritical-fluid chromatography coupled with diode-array detection for the determination of seven emerging contaminants-two pharmaceuticals (carbamazepine and glyburide), three endocrine disruptors (17 alpha-ethinyl estradiol, bisphenol A, and 17 beta-estradiol), one bactericide (triclosan), and one pesticide (diuron)-was developed and validated. These contaminants were chosen because of their frequency of use and their toxic effects on both humans and the environment. The optimized chromatographic separation on a Viridis BEH 2-EP column achieved baseline resolution for all compounds in less than 10 min. This separation was applied to environmental water samples after sample preparation. The optimized sample treatment involved a preconcentration step by means of solid-phase extraction using C18-OH cartridges. The proposed method was validated, finding recoveries higher than 94 % and limits of detection and limits of quantification in the range of 0.10-1.59 mu g L-1 and 0.31-4.83 mu g L-1, respectively. Method validation established the proposed method to be selective, linear, accurate, and precise. Finally, the method was successfully applied to environmental water samples.
引用
收藏
页码:4219 / 4226
页数:8
相关论文
共 50 条
[41]   Determination of tetracyclines in pig and other meat samples using liquid chromatography coupled with diode array and tandem mass spectrometric detectors [J].
Toelgyesi, Adam ;
Toelgyesi, Laszlo ;
Bekesi, Katalin ;
Sharma, Virender K. ;
Fekete, Jeno .
MEAT SCIENCE, 2014, 96 (03) :1332-1339
[42]   Determination of garlic phenolic compounds using supercritical fluid extraction coupled to supercritical fluid chromatography/tandem mass spectrometry [J].
Liu, Jian ;
Ji, Feng ;
Chen, Fengming ;
Guo, Wei ;
Yang, Minli ;
Huang, Shengxiong ;
Zhang, Feng ;
Liu, Yongsheng .
JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2018, 159 :513-523
[43]   Development of an analytical method for eight fluoroquinolones using solid-phase extraction and liquid chromatography with fluorescence detection [J].
Shi, Lu ;
Zhou, Xuefei ;
Zhang, Yalei ;
Gu, Guowei ;
Surampalli, Rao Y. ;
Zhang, Tian C. .
INTERNATIONAL JOURNAL OF ENVIRONMENTAL ANALYTICAL CHEMISTRY, 2010, 90 (14-15) :1085-1098
[44]   Determination of cobalamins (hydroxo-, cyano-, adenosyl- and methyl-cobalamins) in seawater using reversed-phase liquid chromatography with diode-array detection [J].
Suarez-Suarez, Ana ;
Tovar-Sanchez, Antonio ;
Rossello-Mora, Ramon .
ANALYTICA CHIMICA ACTA, 2011, 701 (01) :81-85
[45]   Fast and simultaneous determination of eleven synthetic color additives in flour and meat products by liquid chromatography coupled with diode-array detector and tandem mass spectrometry [J].
Qi, Ping ;
Lin, Zi-hao ;
Chen, Gui-yun ;
Xiao, Jian ;
Liang, Zhi-an ;
Luo, Li-ni ;
Zhou, Jun ;
Zhang, Xue-wu .
FOOD CHEMISTRY, 2015, 181 :101-110
[46]   Screening method for the determination of tetracyclines and fluoroquinolones in animal drinking water by liquid chromatography with diode array detector [J].
Patyra, E. ;
Kowalczyk, E. ;
Grelik, A. ;
Przenioslo-Siwczynska, M. ;
Kwiatek, K. .
POLISH JOURNAL OF VETERINARY SCIENCES, 2015, 18 (02) :283-289
[47]   DETERMINATION OF TRIALKYL AND TRIARYL PHOSPHATES IN SEDIMENT USING MICROWAVE EXTRACTION AND PACKED-CAPILLARY SUPERCRITICAL-FLUID CHROMATOGRAPHY [J].
DEGEUS, H ;
ZEGERS, BN ;
LINGEMAN, H ;
BRINKMAN, UAT .
INTERNATIONAL JOURNAL OF ENVIRONMENTAL ANALYTICAL CHEMISTRY, 1994, 56 (02) :119-132
[48]   Development and validation of a high performance liquid chromatography/diode array detection method for estrogen determination: Application to residual analysis in meat products [J].
Alqahtani, Sadeem S. ;
Bin Humaid, Deema M. ;
Alshail, Sabreen H. ;
AlShammari, Dalai T. ;
Al-Showiman, Hessa ;
Alzoman, Nourah Z. ;
Maher, Hadir M. .
OPEN CHEMISTRY, 2020, 18 (01) :995-1010
[49]   Dispersive solid-phase microextraction method for sample extraction in the analysis of four tetracyclines in water and milk samples by high-performance liquid chromatography with diode-array detection [J].
Tsai, Wen-Hsien ;
Huang, Tzou-Chi ;
Huang, Joh-Jong ;
Hsue, Yi-Huu ;
Chuang, Hung-Yi .
JOURNAL OF CHROMATOGRAPHY A, 2009, 1216 (12) :2263-2269
[50]   Determination of aldicarb, carbofuran and some of their main metabolites in groundwater by application of micellar electrokinetic capillary chromatography with diode-array detection and solid-phase extraction [J].
Arráez-Román, D ;
Segura-Carretero, A ;
Cruces-Blanco, C ;
Fernández-Gutiérrez, A .
PEST MANAGEMENT SCIENCE, 2004, 60 (07) :675-679