Analytical method development for the determination of emerging contaminants in water using supercritical-fluid chromatography coupled with diode-array detection

被引:18
作者
del Carmen Salvatierra-Stamp, Vilma [1 ]
Ceballos-Magana, Silvia G. [2 ]
Gonzalez, Jorge [1 ]
Ibarra-Galvan, Valentin [1 ]
Muniz-Valencia, Roberto [1 ]
机构
[1] Univ Colima, Fac Ciencias Quim, Coquimatlan 28400, Colima, Mexico
[2] Univ Colima, Fac Ciencias, Colima 28045, Mexico
关键词
Emerging contaminants; Supercritical-fluid chromatography; Solid-phase extraction; Environmental water samples; PERFORMANCE LIQUID-CHROMATOGRAPHY; SOLID-PHASE EXTRACTION; TANDEM MASS-SPECTROMETRY; WASTE-WATER; SAMPLES;
D O I
10.1007/s00216-015-8581-x
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
An analytical method using supercritical-fluid chromatography coupled with diode-array detection for the determination of seven emerging contaminants-two pharmaceuticals (carbamazepine and glyburide), three endocrine disruptors (17 alpha-ethinyl estradiol, bisphenol A, and 17 beta-estradiol), one bactericide (triclosan), and one pesticide (diuron)-was developed and validated. These contaminants were chosen because of their frequency of use and their toxic effects on both humans and the environment. The optimized chromatographic separation on a Viridis BEH 2-EP column achieved baseline resolution for all compounds in less than 10 min. This separation was applied to environmental water samples after sample preparation. The optimized sample treatment involved a preconcentration step by means of solid-phase extraction using C18-OH cartridges. The proposed method was validated, finding recoveries higher than 94 % and limits of detection and limits of quantification in the range of 0.10-1.59 mu g L-1 and 0.31-4.83 mu g L-1, respectively. Method validation established the proposed method to be selective, linear, accurate, and precise. Finally, the method was successfully applied to environmental water samples.
引用
收藏
页码:4219 / 4226
页数:8
相关论文
共 50 条
[21]   Signal enhancement in supercritical fluid chromatography-diode-array detection with multiple injection [J].
Sun, Mingzhe ;
Turner, Charlotta ;
Sandahl, Margareta .
JOURNAL OF SEPARATION SCIENCE, 2019, 42 (24) :3727-3737
[22]   SUPERCRITICAL-FLUID CHROMATOGRAPHY OF PETROLEUM-PRODUCTS USING FLAMELESS SULFUR CHEMILUMINESCENCE DETECTION [J].
SHEARER, RL ;
SKELTON, RJ .
HRC-JOURNAL OF HIGH RESOLUTION CHROMATOGRAPHY, 1994, 17 (04) :251-254
[23]   Rapid Determination of Sudan Dyes in chilli products using ultra high performance supercritical fluid chromatography-photodiode array detection [J].
Nie, Xuyuan ;
Xie, Yuejie ;
Wang, Qiang ;
Wei, Huaheng ;
Xie, Chenjing ;
Li, Yamin ;
Wang, Bo ;
Li, Yan .
CYTA-JOURNAL OF FOOD, 2021, 19 (01) :560-570
[24]   Determination of sulfadiazine in Jiaozhou Bay using molecularly imprinted solid-phase extraction followed by high-performance liquid chromatography with a diode-array detector [J].
Lian, Ziru ;
He, Xingliang ;
Wang, Jiangtao .
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2014, 957 :53-59
[25]   Screening method for the determination of selected tetracyclines in water by liquid chromatography with diode array detector [J].
Patyra, Ewelina ;
Kowalczyk, Ewelina ;
Kwiatek, Krzysztof .
BULLETIN OF THE VETERINARY INSTITUTE IN PULAWY, 2014, 58 (01) :65-70
[26]   Development of a precolumn derivatization HPLC method with diode-array detection for the determination of amino sugars in peat and soil humic acids [J].
Beno, Erik ;
Gora, Robert ;
Hutta, Milan .
JOURNAL OF SEPARATION SCIENCE, 2018, 41 (04) :814-821
[27]   Determination of cocaine and benzoylecgonine by direct injection of human urine into a column-switching liquid chromatography system with diode-array detection [J].
Brunetto, MR ;
Cayama, YD ;
García, LG ;
Gallignani, M ;
Obando, MA .
JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2005, 37 (01) :115-120
[28]   On-line dual-precolumn-based trace enrichment for the determination of polar and acidic microcontaminants in river water by liquid chromatography with diode-array UV and tandem mass spectrometric detection [J].
Hogenboom, AC ;
Hofman, MP ;
Jolly, DA ;
Niessen, WMA ;
Brinkman, UAT .
JOURNAL OF CHROMATOGRAPHY A, 2000, 885 (1-2) :377-388
[29]   Rapid analysis of nine lignans in Schisandra chinensis by supercritical fluid chromatography using diode array and mass spectrometric detection [J].
Onay, Sevil ;
Hofer, Stefanie ;
Ganzera, Markus .
JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2020, 185
[30]   Development of a High Pressure Liquid Chromatography with Diode Array Detection Method for the Determination of Four Tetracycline Residues in Milk by Using QuEChERS Dispersive Extraction [J].
Marinou, Eirini ;
Samanidou, Victoria E. ;
Papadoyannis, Ioannis N. .
SEPARATIONS, 2019, 6 (02)