GPU Acceleration of Acoustic Radiation Force Impulse Imaging using Scanning-mode

被引:0
|
作者
Wang, Congzhi [1 ]
Zeng, Bo [1 ]
Xiao, Yang [1 ]
Qiu, Weibao [1 ]
Zheng, Hairong [1 ]
机构
[1] Chinese Acad Sci, Paul C Lauterbur Res Ctr Biomed Imaging, Inst Biomed & Hlth Engn, Shenzhen Inst Adv Technol, Shenzhen, Peoples R China
来源
2014 IEEE INTERNATIONAL ULTRASONICS SYMPOSIUM (IUS) | 2014年
关键词
ULTRASOUND;
D O I
10.1109/ULTSYM.2014.0306
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
Acoustic radiation force impulse (ARFI) system has a more simple hardware architecture than the supersonic shearwave imaging (SSI), which make it easier to be miniaturized for some special clinical practice, such as the emergency treatments in the field first-aid and the donor evaluation for organ transplantation. However, currently ARFI cannot provide 2D stiffness images like SSI can do. To fit this gap, the time-consuming algorithms of ARFI are to be migrated to the graphics processing unit (GPU) for substantial acceleration. In this study, the algorithms of ARFI were modified and improved to fit for the parallel computation on GPU: an analytic signal based cross-correlation method was used to assess the tissue displacements, a cyclic reduction (CR) method was used to calculate the cubic spline interpolation, and a time-of-flight (TOF) method based on Radon transformation was used to determine the shear wave velocity. The ratio of the time consumptions of the programs running on CPU and on GPU was calculated using the practical data collected by our self-developed ARFI system. For the most time-consuming parts such as cross-correlation, filtering, Radon transformation and cubic spline interpolation, large acceleration ratio has been confirmed between the two programs. And a quasi-real-time scanning-mode 2D ARFI (s2D-ARFI) imaging system was implemented by the help of GPU acceleration. Several imaging results on phantom, isolated animal tissue, and in vivo animal are also presented.
引用
收藏
页码:1241 / 1244
页数:4
相关论文
共 50 条
  • [41] ACOUSTIC RADIATION FORCE IMPULSE IMAGING FOR NONINVASIVE CHARACTERIZATION OF CAROTID ARTERY ATHEROSCLEROTIC PLAQUES: A FEASIBILITY STUDY
    Dahl, Jeremy J.
    Dumont, Douglas M.
    Allen, Jason D.
    Miller, Elizabeth M.
    Trahey, Gregg E.
    ULTRASOUND IN MEDICINE AND BIOLOGY, 2009, 35 (05) : 707 - 716
  • [42] Tissue Quantification With Acoustic Radiation Force Impulse Imaging: Measurement Repeatability and Normal Values in the Healthy Liver
    D'Onofrio, Mirko
    Gallotti, Anna
    Mucelli, Roberto Pozzi
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2010, 195 (01) : 132 - 136
  • [43] Impact of Acoustic Radiation Force Impulse Imaging in Clinical Practice of Patients after Orthotopic Liver Transplantation
    Wildner, Dane
    Strobel, Deike
    Konturek, Peter C.
    Goertz, Ruediger S.
    Croner, Roland S.
    Neurath, Markus F.
    Zopf, Steffen
    MEDICAL SCIENCE MONITOR, 2014, 20 : 2027 - 2035
  • [44] Ex vivo study of acoustic radiation force impulse imaging elastography for evaluation of rat liver with steatosis
    Guo, Yanrong
    Dong, Changfeng
    Lin, Haoming
    Zhang, Xinyu
    Wen, Huiying
    Shen, Yuanyuan
    Wang, Tianfu
    Chen, Siping
    Liu, Yingxia
    Chen, Xin
    ULTRASONICS, 2017, 74 : 161 - 166
  • [45] Acoustic Radiation Force Impulse-Imaging for the evaluation of the thyroid gland: A limited patient feasibility study
    Friedrich-Rust, Mireen
    Romenski, Olga
    Meyer, Gesine
    Dauth, Nina
    Holzer, Katharina
    Gruenwald, Frank
    Kriener, Susanne
    Herrmann, Eva
    Zeuzem, Stefan
    Bojunga, Joerg
    ULTRASONICS, 2012, 52 (01) : 69 - 74
  • [46] Acoustic Radiation Force Impulse imaging of in vivo vastus medialis muscle under varying isometric load
    Nightingale, K
    Nightingale, R
    Stutz, D
    Trahey, G
    ULTRASONIC IMAGING, 2002, 24 (02) : 100 - 108
  • [47] Intracardiac echocardiography and acoustic radiation force impulse imaging of a dynamic ex vivo ovine heart model
    Hsu, Stephen J.
    Hubert, Julia L.
    Smith, Stephen W.
    Trahey, Gregg E.
    ULTRASONIC IMAGING, 2008, 30 (02) : 63 - 77
  • [48] Assessment of Spleen Stiffness Using Acoustic Radiation Force Impulse Imaging (ARFI): Definition of Examination Standards and Impact of Breathing Maneuvers
    Karlas, T.
    Lindner, F.
    Troeltzsch, M.
    Keim, V.
    ULTRASCHALL IN DER MEDIZIN, 2014, 35 (01): : 38 - 43
  • [49] Magnetic resonance acoustic radiation force imaging
    McDannold, Nathan
    Maier, Stephan E.
    MEDICAL PHYSICS, 2008, 35 (08) : 3748 - 3758
  • [50] QUANTIFICATION OF PEDIATRIC BURN SCAR STIFFNESS USING ACOUSTIC RADIATION FORCE IMPULSE ULTRASOUND ELASTOGRAPHY
    Zuccaro, Jennifer
    Perez, Manuela M.
    Mohanta, Arun
    Fish, Joel S.
    Doria, Andrea S.
    ULTRASOUND IN MEDICINE AND BIOLOGY, 2019, 45 (08) : 1918 - 1923