Nationwide Energy Saving Analysis of Radiant Floor System for Commercial Buildings

被引:0
作者
Li, Yanfei [1 ]
Niu, Fuxin [1 ]
Qian, Defeng [1 ]
O'Neill, Zheng [1 ]
机构
[1] Univ Alabama, Dept Mech Engn, Tuscaloosa, AL 35401 USA
来源
2018 ASHRAE ANNUAL CONFERENCE | 2018年
关键词
THERMAL COMFORT; COOLING SYSTEMS; PERFORMANCE;
D O I
暂无
中图分类号
O414.1 [热力学];
学科分类号
摘要
The heating, ventilation and air-conditioning (HVAC) system in commercial buildings could take up to about 40% of the whole building energy consumption. Understanding nationwide energy savings potential in buildings for different energy conservation measures (ECMs) has a great impact on increasing the adoption rate of a variety of ECMs. The radiant floor system with a dedicated outdoor air system (DOAS) has proven to be an effective ECM for building cooling and heating, compared to the traditional HVAC system, such as variable air volume (VAV) system in some climate zones. There is a lack of study of the nationwide energy saving potentials of radiant the floor system for all climate zones and all the main commercial building types across the U.S. This paper investigated the energy saving potentials of the radiant floor system with DOAS for 9 commercial building types in 16 climate zones across the U.S. using DOE reference commercial buildings as the baselines. The baselines are ASHRAE 90.1-2010 and MCC-2012 compliant. The selected nine building types are: small office, medium office, hospital outpatient healthcare, restaurant of fast food, restaurant of dinning in, retail standalone, retail of strip mall primary school and secondary school. A whole building simulation program, EnergyPlus, was used for the simulation and the simulation results showed that the energy savings can go as high as 48% depending on the building type and the climate zone, compared to the traditional HVAC system defined in the ASHRAE 90.1-2010 and MCC-2012. The simulation study also showed that the radiant floor system is applicable to all climate zones although them are some savings variations among the different building types. The summarized nationwide energy savings in the U.S for 9 building types and 16climate zones could be used as a design or retrofit guideline for the radiant floor system if desired. In addition, some further studies are proposed for more detailed investigation of radiant floor systems' benefits.
引用
收藏
页数:9
相关论文
共 50 条
  • [31] Experimental Investigation of an Energy Saving System Using Phase Change Materials in buildings
    El-Ghetany, H. H.
    Aly, Wael I. A.
    Shalata, Hany A.
    Eid, A. I.
    Abdelwahed, Khaled
    EGYPTIAN JOURNAL OF CHEMISTRY, 2020, 63 (11): : 4533 - 4544
  • [32] HVAC system strategies for energy conservation in commercial buildings in Saudi Arabia
    Fasiuddin, M.
    Budaiwi, I.
    ENERGY AND BUILDINGS, 2011, 43 (12) : 3457 - 3466
  • [33] Energy saving with passive climate control methods in Spanish office buildings
    Orosa, Jose A.
    Oliveira, Armando C.
    ENERGY AND BUILDINGS, 2009, 41 (08) : 823 - 828
  • [34] Energy Saving Potential of PCMs in Buildings under Future Climate Conditions
    Gassar, Abdo Abdullah Ahmed
    Yun, Geun Young
    APPLIED SCIENCES-BASEL, 2017, 7 (12):
  • [35] Analysis of thermal energy demand and saving in industrial buildings: A case study in Slovakia
    Katunsky, Dusan
    Korjenic, Azra
    Katunska, Jana
    Lopusniak, Martin
    Korjenic, Sinan
    Doroudiani, Saeed
    BUILDING AND ENVIRONMENT, 2013, 67 : 138 - 146
  • [36] An experimental study on using a mass radiant floor with geothermal system as thermal battery of the building
    Tahersima, Mohammad
    Tikalsky, Paul
    Revankar, Roshan
    BUILDING AND ENVIRONMENT, 2018, 133 : 8 - 18
  • [37] A study on dividing heating area of radiant floor heating system
    Joe, G. S.
    Cho, G. Y.
    Lee, S. W.
    Yeo, M. S.
    Kim, K. W.
    FIRST INTERNATIONAL CONFERENCE ON BUILDING ENERGY AND ENVIRONMENT, PROCEEDINGS VOLS 1-3, 2008, : 944 - 951
  • [38] METHODOLOGY FOR DESIGNING RADIANT FLOOR SYSTEM IN MECHANICAL ENGINEERING STUDIES
    Gomez-Moreno, A.
    Palomar-Carnicero, J. M.
    Cruz-Peragon, F.
    INTED2016: 10TH INTERNATIONAL TECHNOLOGY, EDUCATION AND DEVELOPMENT CONFERENCE, 2016, : 4713 - 4723
  • [39] Integrated optimization of energy costs and occupants' productivity in commercial buildings
    Mofidi, Farhad
    Akbari, Hashem
    ENERGY AND BUILDINGS, 2016, 129 : 247 - 260
  • [40] An Experimental Study on Operating Characteristic of Radiant Floor Cooling Integrated with Underfloor Ventilation System
    Cai, Ning
    Zhang, Dongliang
    INTERNATIONAL JOURNAL OF HEAT AND TECHNOLOGY, 2021, 39 (04) : 1207 - 1212