Nationwide Energy Saving Analysis of Radiant Floor System for Commercial Buildings

被引:0
作者
Li, Yanfei [1 ]
Niu, Fuxin [1 ]
Qian, Defeng [1 ]
O'Neill, Zheng [1 ]
机构
[1] Univ Alabama, Dept Mech Engn, Tuscaloosa, AL 35401 USA
来源
2018 ASHRAE ANNUAL CONFERENCE | 2018年
关键词
THERMAL COMFORT; COOLING SYSTEMS; PERFORMANCE;
D O I
暂无
中图分类号
O414.1 [热力学];
学科分类号
摘要
The heating, ventilation and air-conditioning (HVAC) system in commercial buildings could take up to about 40% of the whole building energy consumption. Understanding nationwide energy savings potential in buildings for different energy conservation measures (ECMs) has a great impact on increasing the adoption rate of a variety of ECMs. The radiant floor system with a dedicated outdoor air system (DOAS) has proven to be an effective ECM for building cooling and heating, compared to the traditional HVAC system, such as variable air volume (VAV) system in some climate zones. There is a lack of study of the nationwide energy saving potentials of radiant the floor system for all climate zones and all the main commercial building types across the U.S. This paper investigated the energy saving potentials of the radiant floor system with DOAS for 9 commercial building types in 16 climate zones across the U.S. using DOE reference commercial buildings as the baselines. The baselines are ASHRAE 90.1-2010 and MCC-2012 compliant. The selected nine building types are: small office, medium office, hospital outpatient healthcare, restaurant of fast food, restaurant of dinning in, retail standalone, retail of strip mall primary school and secondary school. A whole building simulation program, EnergyPlus, was used for the simulation and the simulation results showed that the energy savings can go as high as 48% depending on the building type and the climate zone, compared to the traditional HVAC system defined in the ASHRAE 90.1-2010 and MCC-2012. The simulation study also showed that the radiant floor system is applicable to all climate zones although them are some savings variations among the different building types. The summarized nationwide energy savings in the U.S for 9 building types and 16climate zones could be used as a design or retrofit guideline for the radiant floor system if desired. In addition, some further studies are proposed for more detailed investigation of radiant floor systems' benefits.
引用
收藏
页数:9
相关论文
共 50 条
  • [21] Thermal energy simulation of PCM-based radiant floor cooling systems for naturally ventilated buildings in a hot and humid climate
    Kitagawa, Haruka
    Asawa, Takashi
    Rio, Maria Alejandra Del
    Kubota, Tetsu
    Trihamdani, Andhang Rakhmat
    BUILDING AND ENVIRONMENT, 2023, 238
  • [22] A calculation method for the floor surface temperature in radiant floor system
    Jin, Xing
    Zhang, Xiaosong
    Luo, Yajun
    ENERGY AND BUILDINGS, 2010, 42 (10) : 1753 - 1758
  • [23] Combining energy generation and radiant systems: Challenges and possibilities for plus energy buildings
    Carnieletto, Laura
    Kazanci, Ongun B.
    Olesen, Bjarne W.
    Zarrella, Angelo
    Pasut, Wilmer
    ENERGY AND BUILDINGS, 2024, 325
  • [24] Thermal comfort analysis of PCM electric floor radiant heating system
    Chen Qi-zhen
    Feng Guo-hui
    Niu Run-ping
    Li Guo-jian
    Li Wen-jie
    Wang Jian-hui
    JOURNAL OF CENTRAL SOUTH UNIVERSITY OF TECHNOLOGY, 2007, 14 : 111 - 114
  • [25] Experimental and Numerical Simulation of a Radiant Floor System: The Impact of Different Screed Mortars and Floor Finishings
    Almeida, Ricardo M. S. F.
    Vicente, Romeu da Silva
    Ventura-Gouveia, Antonio
    Figueiredo, Antonio
    Rebelo, Filipe
    Roque, Eduardo
    Ferreira, Victor M.
    MATERIALS, 2022, 15 (03)
  • [26] Energy saving potential of thermoelectric radiant cooling panels with a dedicated outdoor air system
    Lim, Hansol
    Jeong, Jae-Weon
    ENERGY AND BUILDINGS, 2018, 169 : 353 - 365
  • [27] Energy retrofit analysis toolkits for commercial buildings: A review
    Lee, Sang Hoon
    Hong, Tianzhen
    Piette, Mary Ann
    Taylor-Lange, Sarah C.
    ENERGY, 2015, 89 : 1087 - 1100
  • [28] A novel radiant floor system: Detailed characterization and comparison with traditional radiant systems
    Shukla, Saunak
    Daneshazarian, Reza
    Mwesigye, Aggrey
    Leong, Wey H.
    Dworkin, Seth B.
    INTERNATIONAL JOURNAL OF GREEN ENERGY, 2020, 17 (02) : 137 - 148
  • [29] A comparative experimental investigation on radiant floor heating system and stratum ventilation
    Li, Han
    Xi, Chang
    Kong, Xiangfei
    Lin, Zhang
    Wang, Lu
    SUSTAINABLE CITIES AND SOCIETY, 2020, 52
  • [30] Simulation analysis of household solar assistant radiant floor heating system in cold area
    Yang, Fei
    Liu, Jian
    Sun, Qie
    Cheng, Lin
    Wennersten, Ronald
    INNOVATIVE SOLUTIONS FOR ENERGY TRANSITIONS, 2019, 158 : 631 - 636