Interocular Symmetry and Repeatability of Central Corneal Thickness and Corneal Endothelial Cell Morphology and Density in Healthy Eyes of Congolese

被引:2
作者
Kelekele, Joseph-Theodore [1 ]
Lubeji, David L. Kayembe [1 ]
Mwanza, Jean-Claude [1 ,2 ]
机构
[1] Univ Hosp Kinshasa, Dept Ophthalmol, Kinshasa, DEM REP CONGO
[2] Univ N Carolina, Dept Ophthalmol, Chapel Hill, NC 27515 USA
关键词
Central corneal thickness; corneal endothelial cell density; interocular symmetry; repeatability; non-contact specular microscopy; INTRAOCULAR-PRESSURE; REPRODUCIBILITY; RELIABILITY; KERATOCONUS;
D O I
10.1080/08820538.2021.1974497
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose To determine the limits of normal interocular symmetry and the repeatability of central corneal thickness (CCT) and endothelial cell morphology and density. Methods Two hundred and seventy-eight subjects (age: 10.9-80.7 years) with healthy eyes were studied. CCT as well as endothelial cell morphology and density were measured by non-contact specular microscopy. Three measurements were obtained per eye per participant. Upper and lower tolerance limits of normal interocular symmetry were defined as the 2.5th and 97.5th percentiles of the interocular differences in CCT, endothelial cell density (CECD), coefficient of variation (CoV), hexagonality, and cell size. Repeatability was determined using the intraclass coefficient correlation (ICC), the coefficient of variation (CV), and the test-retest variability standard deviation (TRTSD). Results The mean interocular differences were -1.05 +/- 17.5 mu m (p = .32) for CCT and 0.5 +/- 90.8 cells/mm(2) (p = .76) for CECD. The 2.5th and 97.5th percentiles of the interocular differences were -13.9 and 15.4 mu m for CCT and -177.4 cells/mm(2) to 182.0 cells/mm(2) for CECD. Only interocular difference in CoV correlated weakly with age (r = -0.22, P < .001). ICCs were 0.93 (95% CI: 0.89-0.96, P < .001) for CCT and 0.95 (0.94-0.96, P < .001) for CECD. CV and TRTSD were 1.2% +/- 5.3% and 4.4 +/- 3.4 mu m for CCT and 2.4% +/- 3.9% and 17.7 +/- 7.7 cells/mm(2) for CECD, respectively. Conclusions CCT and CECD showed good repeatability and interocular symmetry in normal Congolese subjects. Absolute interocular differences in CCT and CECD exceeding 15.5 mu m and 182 cells/mm(2), respectively, should be considered suspicious and investigated. When comparing two intrasession measurements from the same eye, a difference of approximately 4.5 mu m in CCT and 18 cells/mm(2) or greater may be considered statistically significant.
引用
收藏
页码:241 / 248
页数:8
相关论文
共 49 条
[41]   Central Corneal Thickness and its Associations With Ocular and Systemic Factors: The Singapore Malay Eye Study [J].
Su, Daniel H. W. ;
Wong, Tien Y. ;
Foster, Paul J. ;
Tay, Wan-Ting ;
Saw, Seang-Mei ;
Aung, Tin .
AMERICAN JOURNAL OF OPHTHALMOLOGY, 2009, 147 (04) :709-716
[42]   Relationship between asymmetric central corneal thickness and glaucomatous visual field loss within the same patient [J].
Sullivan-Mee, Michael ;
Gentry, James Matthew ;
Qualls, Clifford .
OPTOMETRY AND VISION SCIENCE, 2006, 83 (07) :516-519
[43]   Corneal thickness in an ophthalmologically normal Japanese population [J].
Suzuki, S ;
Suzuki, Y ;
Iwase, A ;
Araie, M .
OPHTHALMOLOGY, 2005, 112 (08) :1327-1336
[44]   Corneal thickness and endothelial morphology in Normal Thai eyes [J].
Tananuvat, Napaporn ;
Khumchoo, Natawan .
BMC OPHTHALMOLOGY, 2020, 20 (01)
[45]   Corneal thickness and relating factors in a popu lation-based study in japan: The tajimi study [J].
Tomidokoro, Atsuo ;
Araie, Makoto ;
Iwase, Aiko .
AMERICAN JOURNAL OF OPHTHALMOLOGY, 2007, 144 (01) :152-154
[46]  
Ul Islam Q, 2017, SAUDI J OPHTHALMOL, V31, P86, DOI 10.1016/j.sjopt.2017.02.009
[47]   Repeatability and reproducibility of corneal thickness using SOCT Copernicus HR [J].
Vidal, Silvia ;
Viqueira, Valentin ;
Mas, David ;
Domenech, Begona .
CLINICAL AND EXPERIMENTAL OPTOMETRY, 2013, 96 (03) :278-285
[48]   Central corneal thickness and its relationship to ocular parameters in young adult myopic eyes [J].
Wang, Qing ;
Liu, Wenwen ;
Wu, Yili ;
Ma, Yan ;
Zhao, Guiqiu .
CLINICAL AND EXPERIMENTAL OPTOMETRY, 2017, 100 (03) :250-254
[49]   Distribution of central corneal thickness and its association with intraocular pressure: The Rotterdam study [J].
Wolfs, RC ;
Klaver, CCW ;
Vingerling, JR ;
Grobbee, DE ;
Hofman, A ;
deJong, PTVM .
AMERICAN JOURNAL OF OPHTHALMOLOGY, 1997, 123 (06) :767-772