Rapid electrochemical detection of domoic acid based on polydopamine/reduced graphene oxide coupled with in-situ imprinted polyacrylamide

被引:10
|
作者
Jiang, Mengnan [1 ]
Tang, Junyan [1 ]
Zhou, Nuoyi [1 ]
Liu, Juan [1 ]
Tao, Feifei [3 ]
Wang, Fei [1 ]
Li, Caolong [1 ,2 ]
机构
[1] China Pharmaceut Univ, Sch Sci, Key Lab Biomed Funct Mat, Nanjing 211198, Peoples R China
[2] Tibetan Tradit Med Coll, Tibetan Med Res Inst, Lhasa 850000, Tibet, Peoples R China
[3] Shaoxing Univ, Dept Chem & Chem Engn, Shaoxing 312000, Peoples R China
关键词
Molecularly imprinted polymer; Electrochemical sensor; Domoic acid; Graphene; Polydopamine; Screen-printed electrode; LINKED-IMMUNOSORBENT-ASSAY; SHELLFISH; SEAWATER; SILICA;
D O I
10.1016/j.talanta.2021.122885
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Domoic acid, namely amnesic shellfish toxin, is a highly neurotoxic substance to marine animals and humankind. To reduce the incidence of poisoning accidents, the exploitation of specific and rapid detection method for domoic acid monitoring is highly required. Herein, an electrochemical molecularly imprinted polymer (MIP) sensor based on polydopamine-reduced graphene oxide/polyacrylamide composite (PDA-rGO/PAM) was constructed successfully to detect domoic acid. The domoic acid molecule could be recognized in imprinted cavities of PAM reversibly through hydrogen bonding. PDA-rGO promoted the loading capacity of PAM and improved the charge transfer rate, which amplified the electrical signal response of the MIP sensor. The screen-printed electrode (SPE) modified with PDA-rGO/PAM displayed satisfactory response toward toxin contaminated sample at a linear range from 1 to 600 nM and a low detection limit of 0.31 nM, demonstrating the prospective application of the transducer as a portable sensing platform for the on-site detection of hazardous marine biotoxin. Moreover, benefiting from the superior specificity and stability of MIP, the fabricated sensor could be utilized to detect the domoic acid content in mussel extracts directly without complex pretreatment operation.
引用
收藏
页数:7
相关论文
共 50 条
  • [41] Electrochemical sensor based on polyamide 6/polypyrrole electrospun nanofibers coated with reduced graphene oxide for malathion pesticide detection
    Migliorini, Fernanda L.
    Sanfelice, Rafaela C.
    Mercante, Luiza A.
    Facure, Murilo H. M.
    Correa, Daniel S.
    MATERIALS RESEARCH EXPRESS, 2020, 7 (01)
  • [42] Surface-Imprinted Acrylamide Polymer-Based Reduced Graphene-Gold Sensor in Rapid and Sensitive Electrochemical Determination of αB-Conotoxin
    Cao, Jia
    Li, Jiayue
    Yu, Tianyang
    Wang, Fei
    SENSORS, 2025, 25 (05)
  • [43] Evaluation of a Nanocomposite Based on Reduced Graphene Oxide and Gold Nanoparticles as an Electrochemical Platform for Detection of Sulfamethazine
    Silva, Martin
    Cesarino, Ivana
    JOURNAL OF COMPOSITES SCIENCE, 2019, 3 (02):
  • [44] Alternative method for rhamnolipids quantification using an electrochemical platform based on reduced graphene oxide, manganese nanoparticles and molecularly imprinted Poly(L-Ser)
    Olsen, Bruna Gabrielle
    Falone, Max Fabricio
    Buffon, Edervaldo
    Yoshimura, Ingrid
    Vale, Rayane da Silva
    Contiero, Jonas
    Stradiotto, Nelson Ramos
    TALANTA, 2024, 272
  • [45] Sensitive Detection of Kynurenic Acid from Biological Fluids Using a Flexible Electrochemical Platform Based on Gold Nanoparticles and Reduced Graphene Oxide
    Macovei, Diana-Gabriela
    Tertis, Mihaela
    Bogdan, Diana
    Suciu, Maria
    Barbu-Tudoran, Lucian
    Cristea, Cecilia
    INTERNATIONAL JOURNAL OF MOLECULAR SCIENCES, 2025, 26 (03)
  • [46] Selective and Sensitive Determination of Folic Acid Based on Molecularly Imprinted Poly (o-aminophenol) and Reduced Graphene Oxide Decorated with Au Nanoparticles
    Peng, Youyuan
    Zhang, Xiaojing
    CURRENT ANALYTICAL CHEMISTRY, 2021, 17 (08) : 1201 - 1210
  • [47] Electrochemical Sensor Based on Nitrogen Doped Porous Reduced Graphene Oxide to Detection of Ciprofloxacin in Pharmaceutical Samples
    Rahimpour, Reyhane
    Sabeti, Bahare
    Chekin, Fereshteh
    RUSSIAN JOURNAL OF ELECTROCHEMISTRY, 2021, 57 (06) : 654 - 662
  • [48] Electrochemical Sensor Based on Nitrogen Doped Porous Reduced Graphene Oxide to Detection of Ciprofloxacin in Pharmaceutical Samples
    Bahare Reyhane Rahimpour
    Fereshteh Sabeti
    Russian Journal of Electrochemistry, 2021, 57 : 654 - 662
  • [49] A sensitive electrochemical sensor based on the partial thermal decomposition of MIL-53(Fe) and reduced graphene oxide for phenol detection
    Zuchao Meng
    Mao Li
    Jingyuan Shao
    Lidong Yan
    Hao Yang
    Xiang Liu
    Ionics, 2021, 27 : 4897 - 4906
  • [50] A sensitive electrochemical sensor based on the partial thermal decomposition of MIL-53(Fe) and reduced graphene oxide for phenol detection
    Meng, Zuchao
    Li, Mao
    Shao, Jingyuan
    Yan, Lidong
    Yang, Hao
    Liu, Xiang
    IONICS, 2021, 27 (11) : 4897 - 4906