Application of exergoeconomic techniques to the optimization of a refrigeration evaporator coil with continuous fins

被引:8
作者
Khir, Tahar
Jassim, Rahim K.
Zaki, Galal M.
机构
[1] Jeddah Coll Technol, Jeddah 21541, Saudi Arabia
[2] Yanbu Ind Coll, Royal Commiss Jubail & Yanbu, Yanbu Ind City 21477, Saudi Arabia
[3] King Abdulaziz Univ, Jeddah 21587, Saudi Arabia
来源
JOURNAL OF ENERGY RESOURCES TECHNOLOGY-TRANSACTIONS OF THE ASME | 2007年 / 129卷 / 03期
关键词
exergy analysis; exergy destruction units; thermoeconomic optimization; refrigeration evaporator;
D O I
10.1115/1.2751507
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
An optimization for the geometrical parameters of continuous fins on an array of tubes of a refrigeration evaporator is developed in this paper using the exergy method. The method is based on exergy, economic analysis, and optimization theory. As there are humid air and refrigerant single- and two-phase streams involved in the heat transfer process, then there are irreversibilities or exergy destruction, due to pressure losses PIP, due to temperature difference I-Delta T and due to specific humidity gradient I-Delta T. These principal components of total irreversibility are not independent, and their relative contribution to total irreversibility of a cross-flow refrigeration evaporator is investigated. A change in geometry was obtained by varying the evaporator tube diameter for a selected evaporator capacity, and hence the evaporator tube length and total heat transfer area are calculated for a fixed evaporator face length. In this way, the effect of changes in the geometry on the total number of exergy destruction units of the heat exchange process is investigated. The optimum balance between the three components of irreversibility (I-Delta P, I-Delta T, and I-Delta w) is also determined, thereby giving the optimum solution for the heat exchanger area. The total cost function, which provides a measure of the contribution of the evaporator to the total cost of the refrigeration system, is expressed on the basis of annual capital and electrical energy costs. The total cost function is minimized with respect to the total heat transfer area anti the total number of exergy destruction units (NI). The relationship between the operational variables, heat transfer area, refrigerant and air irreversibilities, and the total annual cost for this type of evaporator are developed, presented, and discussed. The pressure, temperature, and specific humidity irreversibilities are found to be 30.34%, 33.78%, and 35.88%, respectively, of the total irreversibility, which is 8.5% of the evaporator capacity.
引用
收藏
页码:266 / 277
页数:12
相关论文
共 27 条
[1]  
[Anonymous], 2005, HEATING VENTILATING
[2]  
ASHRAE, 2001, Fundamentals Handbook
[3]  
Bejan A., 1997, ADV ENG THERMODYNAMI, V2nd
[4]  
Bejan A., 1996, Thermal Design and Optimization, DOI DOI 10.1016/S0140-7007(97)87632-3
[5]  
BEJAN A, 1987, P 4 INT S 2 LAW AN T, P1
[6]  
*BITZ LTD, 2004, EV SEL MAN
[7]  
CAN A, 2002, EXERGY INT J, V2, P113
[8]  
CHEN JC, 1966, I EC PROCESS DES DEV, V5, P3
[9]   Thermoeconomic optimisation of the condenser in a vapour compression heat pump [J].
d'Accadia, MD ;
Vanoli, L .
INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2004, 27 (04) :433-441
[10]   FRICTIONAL PRESSURE DROP IN 2-PHASE FLOW .B. AN APPROACH THROUGH SIMILARITY ANALYSIS [J].
DUKLER, AE ;
WICKS, M ;
CLEVELAND, RG .
AICHE JOURNAL, 1964, 10 (01) :44-51