Ultra short term analysis of heart rate variability using normal sinus rhythm and atrial fibrillation ECG data

被引:0
作者
Salahuddin, Lizawati [1 ]
Jeong, Mycong Gi [1 ]
Kim, Desok [1 ]
机构
[1] Informat & Commun Univ, Sch Engn, Taejon, South Korea
来源
HEALTHCOM 2007: UBIQUITOUS HEALTHCARE IN AGING SOCIETIES | 2007年
关键词
heart rate variability; ECG; normal sinus rhythm; atrialfibrillarion; short term analysis;
D O I
暂无
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
Heart rate variability (HRV) analysis is well established as a quantitative predictor of clinical cardiac events. To provide reliable assessment of HRV in mobile settings, short duration ECG recordings may be analyzed since the conventional five min measurement might be inadequately long. In this study, HRV features were calculated in variable time lengths of long term mobile ECG data. The ultra short term HRV features as reliable as five min measurement were found using Kruskal-Wallis test (p > 0.05). However, these HRV features may not have any clinical relevance. Thus, two sets of HRV features were calculated from varying lengths of normal sinus rhythm and atrial fibrillation ECG data. Finally, ultra short term HRV features were obtained from the shortest ECG data segments that produced significant differences between the two sets of HRV features. These results suggested that we could assess the cardiac activity of individuals accurately and conveniently by ultra short term ECG recordings from mobile sensors.
引用
收藏
页码:240 / +
页数:3
相关论文
共 19 条
  • [1] Discrimination between healthy and sick cardiac autonomic nervous system by detrended heart rate variability analysis
    Ashkenazy, Y
    Lewkowicz, M
    Levitan, J
    Havlin, S
    Saermark, K
    Moelgaard, H
    Thomsen, PEB
    [J]. FRACTALS-COMPLEX GEOMETRY PATTERNS AND SCALING IN NATURE AND SOCIETY, 1999, 7 (01) : 85 - 91
  • [2] BAKER JP, 2006, P EL NZ C ENZ CON 20
  • [3] Bayevsky R.M., 2002, HRV Analysis under the usage of different electrocardiography systems (Methodical recommendations)
  • [4] Camm AJ, 1996, CIRCULATION, V93, P1043
  • [5] A wearable ECG-recording system for continuous arrhythmia monitoring in a wireless tele-home-care situation
    Fensli, R
    Gunnarson, E
    Gundersen, T
    [J]. 18TH IEEE SYMPOSIUM ON COMPUTER-BASED MEDICAL SYSTEMS, PROCEEDINGS, 2005, : 407 - 412
  • [6] PhysioBank, PhysioToolkit, and PhysioNet - Components of a new research resource for complex physiologic signals
    Goldberger, AL
    Amaral, LAN
    Glass, L
    Hausdorff, JM
    Ivanov, PC
    Mark, RG
    Mietus, JE
    Moody, GB
    Peng, CK
    Stanley, HE
    [J]. CIRCULATION, 2000, 101 (23) : E215 - E220
  • [7] Krco S, 2003, ENG MED BIOL SOC ANN, P350
  • [8] LEIJDEKKERS P, 2006, MOBILE BUSINESS ICMB, P29
  • [9] Reliability and accuracy of heart rate variability metrics versus ECG segment duration
    McNames, James
    Aboy, Mateo
    [J]. MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 2006, 44 (09) : 747 - 756
  • [10] OLIVER N, 2006, INT WORKSH WEAR IMPL, P4