A New Fault-Location Algorithm for Series-Compensated Double-Circuit Transmission Lines Based on the Distributed Parameter Model

被引:30
作者
Zhang, Ying [1 ]
Liang, Jun [1 ]
Yun, Zhihao [1 ]
Dong, Xiaoming [1 ]
机构
[1] Shandong Univ, Sch Elect Engn, Jinan 250100, Shandong, Peoples R China
关键词
Double-circuit transmission lines; series compensation; two terminals; six-sequence component; distributed parameter line model; DETECTION/LOCATION TECHNIQUE; CAPACITORS;
D O I
10.1109/TPWRD.2016.2626476
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
A new two-terminal fault-location algorithm for series-compensated double-circuit transmission lines based on the distributed parameter line model is proposed. The system is considered as fully transposed, and a six-sequence component network is introduced to decouple the mutual electromagnetic effects between circuits. Two subroutines designated for the fault that occurs on the left or right side of the series compensator are developed. In each subroutine, the voltage of the series-compensated device is eliminated based on the fact that the sequence voltages calculated from two sides are equal at the fault point. The fault-location function is constructed by utilizing the feature in which the transition resistance is purely resistant at the fault point. The proposed algorithm does not rely on the equivalent model of a series-compensated device. Moreover, it does not require the fault type to be known, and there are no fault-location identification and pseudoroot elimination problems. PSCAD is employed to generate numerous fault cases in diverse conditions and the high accuracy of the proposed fault-location algorithm is validated in MATLAB.
引用
收藏
页码:2398 / 2407
页数:10
相关论文
共 35 条
[1]   A Novel Fault-Location Algorithm for Long Transmission Lines Compensated by Series FACTS Devices [J].
Ahsaee, Mahdi Ghazizadeh ;
Sadeh, Javad .
IEEE TRANSACTIONS ON POWER DELIVERY, 2011, 26 (04) :2299-2308
[2]  
[Anonymous], P 33 ANN W PROT REL
[3]  
[Anonymous], 2005, C9512005 IEEE, DOI [10.1109/IEEESTD.2006.99501, DOI 10.1109/IEEESTD.2006.99501]
[4]   Generalized formulation of the optimal monitor placement problem for fault location [J].
Avendano-Mora, M. ;
Milanovic, J. V. .
ELECTRIC POWER SYSTEMS RESEARCH, 2012, 93 :120-126
[5]   Supplementary Impedance-Based Fault-Location Algorithm for Series-Compensated Lines [J].
Bains, Tirath Pal S. ;
Zadeh, Mohammad R. Dadash .
IEEE TRANSACTIONS ON POWER DELIVERY, 2016, 31 (01) :334-342
[6]   Application of six-sequence fault components in fault location for joint parallel transmission line [J].
Fan, C. (chunjuc@online.sh.cn), 2005, Tsinghua University Press (10) :247-253
[7]   A LINEARIZED MODEL FOR MOV-PROTECTED SERIES CAPACITORS [J].
GOLDSWORTHY, DL .
IEEE TRANSACTIONS ON POWER SYSTEMS, 1987, 2 (04) :953-958
[8]   Fault Location on Double-Circuit Series-Compensated Lines Using Two-End Unsynchronized Measurements [J].
Izykowski, Jan ;
Rosolowski, Eugeniusz ;
Balcerek, Przemyslaw ;
Fulczyk, Marek ;
Saha, Murari Mohan .
IEEE TRANSACTIONS ON POWER DELIVERY, 2011, 26 (04) :2072-2080
[9]   Accurate Noniterative Fault Location Algorithm Utilizing Two-End Unsynchronized Measurements [J].
Izykowski, Jan ;
Rosolowski, Eugeniusz ;
Balcerek, Przemyslaw ;
Fulczyk, Marek ;
Saha, Murari Mohan .
IEEE TRANSACTIONS ON POWER DELIVERY, 2010, 25 (01) :72-80
[10]   SERIES CAPACITORS IN POWER-SYSTEMS [J].
JANCKE, G ;
FAHLEN, N ;
NERF, O .
IEEE TRANSACTIONS ON POWER APPARATUS AND SYSTEMS, 1975, PA94 (03) :915-925