Effect of the Metro Train on the Smoke Back-Layering Length under Different Tunnel Cross-Sections

被引:2
|
作者
Wang, Meng [1 ,2 ]
Liu, Henan [1 ]
Wang, Fei [1 ]
Shen, Linhan [1 ]
Weng, Miaocheng [1 ]
机构
[1] Chongqing Univ, Sch Civil Engn, Chongqing 400045, Peoples R China
[2] Chongqing Railway Grp Co Ltd, Chongqing 400025, Peoples R China
来源
APPLIED SCIENCES-BASEL | 2022年 / 12卷 / 13期
基金
中国国家自然科学基金;
关键词
metro tunnel fire; FDS simulation; smoke back-layering length; metro train; tunnel cross-section; CRITICAL VENTILATION VELOCITY; LONGITUDINAL VENTILATION; SUBWAY TUNNEL; BACKLAYERING LENGTH; POINT EXTRACTION; FIRE; FLOW; BLOCKAGE; TEMPERATURE; COMBINATION;
D O I
10.3390/app12136775
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
Smoke back-layering length is an important aspect of tunnel fire research, and the influence of metro train blockage cannot be ignored. In previous studies, less attention has been paid to the phenomenon of back-layering caused by the same train blocked in tunnels with different cross-sections. This paper investigates this point through dimensionless analysis and fire dynamic simulator (FDS) numerical simulation. Several full-scale model tunnels (300 m in length), with different tunnel cross-sections, were constructed in FDS. According to the FDS simulation result, the smoke back-layering length was compared and analyzed. To investigate the effect of the tunnel cross-sections on smoke back-layering length under metro train blocking, the headroom ratio epsilon was proposed. Then, the influence of the tunnel cross-section on the smoke back-layering length was discussed in detail. Based on the dimensional analysis and FDS simulation results, a new model for predicting the smoke back-layering length was proposed. The prediction model obtained in this paper was compared with the FDS simulation results and the prediction model proposed by our predecessors. It is proven that the proposed model can better predict the length of smoke back-layering when metro trains are blocked in tunnels with different cross-sections. The outcomes of this work are expected to provide theoretical guidance for fire smoke control in metro tunnels with different cross-sections.
引用
收藏
页数:18
相关论文
共 50 条
  • [41] Thermal buoyant smoke back-layering flow length in a longitudinal ventilated tunnel with ceiling extraction at difference distance from heat source
    Chen, L. F.
    Hu, L. H.
    Zhang, X. L.
    Zhang, X. Z.
    Zhang, X. C.
    Yang, L. Z.
    APPLIED THERMAL ENGINEERING, 2015, 78 : 129 - 135
  • [42] Study of critical velocity and back-layering length with fire sources both inside and outside a tunnel
    Fan, Chuangang
    Zeng, Wenxin
    Jiao, Ao
    Chen, Hao
    Bu, Rongwei
    An, Weiguang
    Ni, Shuna
    FIRE SAFETY JOURNAL, 2023, 141
  • [43] Effects of ambient pressure on the critical velocity and back-layering length in longitudinal ventilated tunnel fire
    Yan, Guanfeng
    Wang, Mingnian
    Yu, Li
    Tian, Yuan
    INDOOR AND BUILT ENVIRONMENT, 2020, 29 (07) : 1017 - 1027
  • [44] The aerodynamic sizing of tunnel cross-sections for train operation
    Gawthorpe, RG
    Johnson, T
    FiguraHardy, GI
    INTERNATIONAL RAILWAY CONFERENCE ON BETTER JOURNEY TIME - BETTER BUSINESS: SELECTED PAPERS PRESENTED AT S TECH '96, 1996, 1996 (08): : 259 - 269
  • [45] Study on the double effect of the tunnel slope on the fire induced smoke back-layering distance in naturally ventilated inclined tunnels
    Sun, Jiayun
    Wang, Junheng
    Fang, Zheng
    Tang, Zhi
    Merci, Bart
    TUNNELLING AND UNDERGROUND SPACE TECHNOLOGY, 2024, 143
  • [46] Prediction of Back-layering Length and Critical Velocity with Lithium-ion Battery Car Fires in Tunnel
    Bai, Zhenpeng
    Zhao, Xiaohan
    Song, Huaitao
    Zhang, Yang
    Yao, Haowei
    Zhang, Jin
    IAENG International Journal of Applied Mathematics, 2024, 54 (06) : 1033 - 1037
  • [47] A numerical study on critical velocity and back-layering length with trains' blockage in longitudinally ventilated tunnel fires
    Zhang, Xiaochun
    Zhang, Zhenyi
    Tao, Haowen
    TUNNELLING AND UNDERGROUND SPACE TECHNOLOGY, 2021, 116
  • [48] Effect of blockage-fire distance on buoyancy driven back-layering length and critical velocity in a tunnel: An experimental investigation and global correlations
    Tang, W.
    Hu, L. H.
    Chen, L. F.
    APPLIED THERMAL ENGINEERING, 2013, 60 (1-2) : 7 - 14
  • [49] Critical ventilation velocity under the blockage of different metro train in a long metro tunnel
    Zhang, Shaogang
    Shi, Long
    Li, Xianbin
    Huang, Yilong
    He, Kun
    Wang, Jinhui
    FIRE AND MATERIALS, 2020, 44 (04) : 497 - 505
  • [50] Numerical Investigation of Back-Layering Length and Critical Velocity in Curved Subway Tunnels with Different Turning Radius
    Shaogang Zhang
    Hui Yang
    Yongzheng Yao
    Kai Zhu
    Yong Zhou
    Long Shi
    Xudong Cheng
    Fire Technology, 2017, 53 : 1765 - 1793