Transient tracking of low and high-order eccentricity-related components in induction motors via TFD tools

被引:25
作者
Climente-Alarcon, V. [1 ]
Antonino-Daviu, J. [1 ]
Riera-Guasp, M. [1 ]
Pons-Llinares, J. [1 ]
Roger-Folch, J. [1 ]
Jover-Rodriguez, P. [2 ]
Arkkio, A. [3 ]
机构
[1] Univ Politecn Valencia, Dept Ingn Elect, E-46071 Valencia, Spain
[2] ABB Corp Res, S-72222 Vasteras, Sweden
[3] Aalto Univ, Dept Elect Engn, FI-00076 Helsinki, Finland
关键词
Fault diagnosis; Eccentricities; Wigner-Ville transform; Transient analysis; Induction motors; BROKEN ROTOR BARS; DISCRETE WAVELET TRANSFORM; FAULT-DIAGNOSIS; MACHINES; HILBERT; DWT;
D O I
10.1016/j.ymssp.2010.08.008
中图分类号
TH [机械、仪表工业];
学科分类号
0802 ;
摘要
The present work is focused on the diagnosis of mixed eccentricity faults in induction motors via the study of currents demanded by the machine. Unlike traditional methods, based on the analysis of stationary currents (Motor Current Signature Analysis (MCSA)), this work provides new findings regarding the diagnosis approach proposed by the authors in recent years, which is mainly focused on the fault diagnosis based on the analysis of transient quantities, such as startup or plug stopping currents (Transient Motor Current Signature Analysis (TMCSA)), using suitable time-frequency decomposition (TFD) tools. The main novelty of this work is to prove the usefulness of tracking the transient evolution of high-order eccentricity-related harmonics in order to diagnose the condition of the machine, complementing the information obtained with the low-order components, whose transient evolution was well characterised in previous works. Tracking of high-order eccentricity-related harmonics during the transient, through their associated patterns in the time-frequency plane, may significantly increase the reliability of the diagnosis, since the set of fault-related patterns arising after application of the corresponding TFD tool is very unlikely to be caused by other faults or phenomena. Although there are different TFD tools which could be suitable for the transient extraction of these harmonics, this paper makes use of a Wigner-Ville distribution (WVD)-based algorithm in order to carry out the time-frequency decomposition of the startup current signal, since this is a tool showing an excellent trade-off between frequency resolution at both high and low frequencies. Several simulation results obtained with a finite element-based model and experimental results show the validity of this fault diagnosis approach under several faulty and operating conditions. Also, additional signals corresponding to the coexistence of the eccentricity and other non-fault related phenomena making difficult the diagnosis (fluctuating load torque) are included in the paper. Finally, a comparison with an alternative TFD tool the discrete wavelet transform (DWT) - applied in previous papers, is also carried out in the contribution. The results are promising regarding the usefulness of the methodology for the reliable diagnosis of eccentricities and for their discrimination against other phenomena. (C) 2010 Elsevier Ltd. All rights reserved.
引用
收藏
页码:667 / 679
页数:13
相关论文
共 33 条
  • [21] Instantaneous Frequency of the Left Sideband Harmonic During the Start-Up Transient: A New Method for Diagnosis of Broken Bars
    Pineda-Sanchez, Manuel
    Riera-Guasp, Martin
    Alfonso Antonino-Daviu, Jose
    Roger-Folch, Jose
    Perez-Cruz, Juan
    Puche-Panadero, Ruben
    [J]. IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2009, 56 (11) : 4557 - 4570
  • [22] PONSLLINARES J, 2009, IEEE INT S DIAGN EMP
  • [23] Numerical magnetic field analysis and signal processing for fault diagnostics of electrical machines
    Pöyhönen, S
    Negrea, M
    Jover, P
    Arkkio, A
    Hyötyniemi, H
    [J]. COMPEL-THE INTERNATIONAL JOURNAL FOR COMPUTATION AND MATHEMATICS IN ELECTRICAL AND ELECTRONIC ENGINEERING, 2003, 22 (04) : 969 - 981
  • [24] Puche-Panadero R, 2009, 2009 IEEE INTERNATIONAL ELECTRIC MACHINES & DRIVES CONFERENCE, VOLS 1-3, P1428
  • [25] Bearing fault diagnosis using FFT of intrinsic mode functions in Hilbert-Huang transform
    Rai, V. K.
    Mohanty, A. R.
    [J]. MECHANICAL SYSTEMS AND SIGNAL PROCESSING, 2007, 21 (06) : 2607 - 2615
  • [26] A General Approach for the Transient Detection of Slip-Dependent Fault Components Based on the Discrete Wavelet Transform
    Riera-Guasp, M.
    Antonino-Daviu, Jose A.
    Pineda-Sanchez, M.
    Puche-Panadero, R.
    Perez-Cruz, J.
    [J]. IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2008, 55 (12) : 4167 - 4180
  • [27] ROSERO J, 2007, IEEE INT S DIAGN EL
  • [28] Evaluation and implementation of a system to eliminate arbitrary load effects in current-based monitoring of induction machines
    Schoen, RR
    Habetler, TG
    [J]. IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 1997, 33 (06) : 1571 - 1577
  • [29] Detection of broken rotor bars in induction motor using starting-current analysis and effects of loading
    Supangat, R.
    Ertugrul, N.
    Soong, W. L.
    Gray, D. A.
    Hansen, C.
    Grieger, J.
    [J]. IEE PROCEEDINGS-ELECTRIC POWER APPLICATIONS, 2006, 153 (06): : 848 - 855
  • [30] Current signature analysis to detect induction motor faults
    Thomson, WT
    Fenger, M
    [J]. IEEE INDUSTRY APPLICATIONS MAGAZINE, 2001, 7 (04) : 26 - 34