Acoustic emission characteristics of concrete cylinders reinforced with steel-fiber-reinforced composite bars under uniaxial compression

被引:24
作者
Tang, Yu [1 ]
Guo, Yuzhu [2 ]
Chen, Xudong [2 ]
Wang, Zhen [2 ]
Wei, Yang [1 ]
机构
[1] Nanjing Forestry Univ, Coll Civil Engn, Nanjing 210037, Peoples R China
[2] Hohai Univ, Coll Civil & Transportat Engn, Nanjing 210098, Peoples R China
来源
JOURNAL OF BUILDING ENGINEERING | 2022年 / 59卷
基金
中国国家自然科学基金;
关键词
Acoustic emission; Concrete cylinder; Steel -fiber -reinforced composite bar; Uniaxial compression; Damage characteristic; LONGITUDINAL REINFORCEMENT; BEHAVIOR; BEAMS;
D O I
10.1016/j.jobe.2022.105074
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
An experimental study of the acoustic emission characteristics of concrete cylinders reinforced with steel fiber-reinforced composite bars (SFCB) under uniaxial compression was performed. SFCB-reinforced concrete cylinders, plain concrete cylinders, and fiber-reinforced polymer (FRP) bar-reinforced concrete cylinders were tested under uniaxial compression. The entire failure process of different concrete cylinders was monitored in real time using acoustic emissions (AE). Damage characteristics of the cylinders were analyzed using the AE hit number distribution, Ib value analysis method, and AE event location and energy. The Ib value characteristics were closely correlated with the microcracks and their extension inside the concrete cylinders. For the reinforced concrete cylinders, the damages were predominantly microcracks of the concrete observed before the first turning point of the load-displacement curve. Subsequently, damage to the longitudinal SFCBs and FRP bars occurred. The AE characteristic of FRP reinforcement damage was similar to that of the macroscopic crack damage in concrete, that is, with a small Ib value. According to the AE event location analysis, the plain concrete cylinder demonstrated obvious shear failure, which was primarily suppressed in the reinforced concrete cylinders owing to the confinement effect of the spiral. The AE energy released by the compression damage of the longitudinal FRP bar was higher than that released by the tensile damage of the FRP spiral. This could trigger a distinguishable high AE location source amplitude for detecting the compression damage to the FRP bar. The analysis of the AE event distribution characteristics proves that the SFCB has a stable post-yield stage, and the compressive damage process of the SFCB is relatively stable and mild compared with the FRP bars in concrete cylinders.
引用
收藏
页数:13
相关论文
共 34 条
  • [11] Corrosion mechanisms in reinforced concrete by acoustic emission
    Kawasaki, Yuma
    Wakuda, Tomoyo
    Kobarai, Tomoe
    Ohtsu, Masayasu
    [J]. CONSTRUCTION AND BUILDING MATERIALS, 2013, 48 : 1240 - 1247
  • [12] AE monitoring of corrosion process in cyclic wet-dry test
    Kawasaki, Yuma
    Tomoda, Yuichi
    Ohtsu, Masayasu
    [J]. CONSTRUCTION AND BUILDING MATERIALS, 2010, 24 (12) : 2353 - 2357
  • [13] Fracture behavior of flax fibers reinforced earth concrete
    Kouta, Nathalie
    Saliba, Jacqueline
    Saiyouri, Nadia
    [J]. ENGINEERING FRACTURE MECHANICS, 2021, 241
  • [14] Acoustic emission behavior of polyvinyl alcohol (PVA) fiber reinforced calcium sulphoaluminate cement mortar under flexural load
    Li, Jingjun
    Yan, Jun
    Xue, Gang
    Niu, Jiangang
    [J]. JOURNAL OF BUILDING ENGINEERING, 2021, 40
  • [15] Acoustic emission monitoring and finite element analysis of debonding in fiber-reinforced polymer rebar reinforced concrete
    Li, Weijie
    Ho, Siu Chun Michael
    Patil, Devendra
    Song, Gangbing
    [J]. STRUCTURAL HEALTH MONITORING-AN INTERNATIONAL JOURNAL, 2017, 16 (06): : 674 - 681
  • [16] Relation between the shear stress distribution and the resulting acoustic emission variation in concrete beams
    Liu, Simeng
    Wu, Caixing
    Zhou, Jianting
    Liu, Tenfei
    Zhuang, Shaoqi
    Luo, Yulin
    Yang, Xu
    [J]. STRUCTURAL CONTROL & HEALTH MONITORING, 2020, 27 (06)
  • [17] Nanni A., 1994, Constr. Build. Mater, V8, P89, DOI [10.1016/S0950-0618(09)90017-4, DOI 10.1016/S0950-0618(09)90017-4]
  • [18] Nanni A, 1994, CONSTR BUILD MATER, V8, P27
  • [19] Diagnostic of fatigue damage severity on reinforced concrete beam using acoustic emission technique
    Nor, Noorsuhada Md
    Ibrahim, Azmi
    Bunnori, Norazura Muhamad
    Saman, Hamidah Mohd
    Saliah, Soffian Noor Mat
    Shahidan, Shahiron
    [J]. ENGINEERING FAILURE ANALYSIS, 2014, 41 : 1 - 9
  • [20] Use of DIC and AE for Monitoring Effective Strain and Debonding in FRP and FRCM-Retrofitted RC Beams
    Pohoryles, Daniel A.
    Melo, Jose
    Rossetto, Tiziana
    Fabian, Matthias
    McCague, Colum
    Stavrianaki, Katerina
    Lishman, Ben
    Sargeant, Ben
    [J]. JOURNAL OF COMPOSITES FOR CONSTRUCTION, 2017, 21 (01)