The effects of roof covering on the thermal performance of highly insulated roofs in Mediterranean climates

被引:48
作者
D'Orazio, M. [1 ]
Di Perna, C. [2 ]
Di Giuseppe, E. [1 ]
机构
[1] Marche Polytech Univ, Fac Engn, Dept Architecture Construct & Struct, I-60131 Ancona, Italy
[2] Marche Polytech Univ, Fac Engn, Dept Energet, I-60131 Ancona, Italy
关键词
Thermal insulation; Mediterranean climate; Roof; Energy saving; Passive cooling; Over insulation; Building envelope; Summer comfort; EXTERNAL WALLS; TROPICAL CLIMATES; BUILDING ROOF; THICKNESS; SUMMER; LOAD;
D O I
10.1016/j.enbuild.2010.04.004
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
While the EU Directive 2002/91/CE on the Energy Performance of Buildings (EPBD) clearly establishes regulations for the thermal insulation of buildings for saving energy in winter, the summer strategy is described by a little more than qualitative provisions. As a consequence, in the national requirements, the high insulation of the building envelope is considered as the principal strategy to control energy consumption even in summer, regardless of the different climates. This approach leads to a homologation of the building trade, and imposes construction technology and materials which do not adhere to the traditional way of making buildings, like in Southern Europe. Here, the "over insulation" of buildings runs the risk of reducing the effectiveness of traditional passive cooling strategies (thermal mass, air permeability of the roof covering, roof ventilation) and could have adverse effects on internal comfort. In this paper, we focus on the effects of over insulation on the thermal performance of roofs in summer, by analyzing experimental data from monitoring a full-scale mock-up in Italy. Results show how an increase in insulation thickness reduces the effectiveness of traditional passive cooling strategies, as an effect of the thermal decoupling between the interior and the upper layers of the roofs. (C) 2010 Elsevier B.V. All rights reserved.
引用
收藏
页码:1619 / 1627
页数:9
相关论文
共 27 条
  • [21] Determination of optimum insulation thicknesses of the external walls and roof (ceiling) for Turkey's different degree-day regions
    Sisman, Nuri
    Kahya, Emin
    Aras, Nil
    Aras, Haydar
    [J]. ENERGY POLICY, 2007, 35 (10) : 5151 - 5155
  • [22] Experimental evaluation of insulation material in roofing system under tropical climate
    Soubdhan, T
    Feuillard, T
    Bade, F
    [J]. SOLAR ENERGY, 2005, 79 (03) : 311 - 320
  • [23] *UNI EN ISO, 137862006 UNI EN ISO
  • [24] *UNI EN ISO, 69462008 UNO EN ISO
  • [25] A performance of hollow clay tile (HCT) laid reinforced cement concrete (RCC) roof for tropical summer climates
    Vijaykumar, K. C. K.
    Srinivasan, P. S. S.
    Dhandapani, S.
    [J]. ENERGY AND BUILDINGS, 2007, 39 (08) : 886 - 892
  • [26] A study on optimum insulation thicknesses of external walls in hot summer and cold winter zone of China
    Yu, Jinghua
    Yang, Changzhi
    Tian, Liwei
    Liao, Dan
    [J]. APPLIED ENERGY, 2009, 86 (11) : 2520 - 2529
  • [27] 2008, COUNTRY STATUS REPOR