Fetal Mouse Cardiovascular Imaging Using a High-frequency Ultrasound (30/45MHZ) System

被引:3
|
作者
Touma, Marlin [1 ,2 ]
机构
[1] Univ Calif Los Angeles, David Geffen Sch Med, Neonatal Congenital Heart Lab, Cardiovasc Res Lab, Los Angeles, CA 90095 USA
[2] Univ Calif Los Angeles, David Geffen Sch Med, Dept Pediat, Childrens Discovery & Innovat Inst, Los Angeles, CA 90095 USA
来源
JOVE-JOURNAL OF VISUALIZED EXPERIMENTS | 2018年 / 135期
关键词
Developmental Biology; Issue; 135; Congenital Heart Defects; Genetics; Echocardiography; Fetal Circulation; Cardiac Development; Heart Maturation; Cardiovascular Physiology; CONGENITAL HEART-DISEASE; LATE-GESTATION; DEFECTS; RISK;
D O I
10.3791/57210
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
Congenital heart defects (CHDs) are the most common cause of childhood morbidity and early mortality. Prenatal detection of the underlying molecular mechanisms of CHDs is crucial for inventing new preventive and therapeutic strategies. Mutant mouse models are powerful tools to discover new mechanisms and environmental stress modifiers that drive cardiac development and their potential alteration in CHDs. However, efforts to establish the causality of these putative contributors have been limited to histological and molecular studies in non-survival animal experiments, in which monitoring the key physiological and hemodynamic parameters is often absent. Live imaging technology has become an essential tool to establish the etiology of CHDs. In particular, ultrasound imaging can be used prenatally without surgically exposing the fetuses, allowing maintaining their baseline physiology while monitoring the impact of environmental stress on the hemodynamic and structural aspects of cardiac chamber development. Herein, we use the High-Frequency Ultrasound (30/45) system to examine the cardiovascular system in fetal mice at E18.5 in utero at the baseline and in response to prenatal hypoxia exposure. We demonstrate the feasibility of the system to measure cardiac chamber size, morphology, ventricular function, fetal heart rate, and umbilical artery flow indices, and their alterations in fetal mice exposed to systemic chronic hypoxia in utero in real time.
引用
收藏
页数:10
相关论文
共 50 条
  • [41] Simultaneous photoacoustic and high-frequency ultrasound imaging of in vivo embryonic-mouse vasculature
    Aristizabal, Orlando
    Turnbull, Daniel H.
    Sampathkumar, Ashwin
    Mamou, Jonathan
    Filoux, Erwin
    Ketterling, Jeffrey A.
    Chitnis, Parag
    2011 IEEE INTERNATIONAL ULTRASONICS SYMPOSIUM (IUS), 2011, : 288 - 291
  • [42] Use of ultra high-frequency ultrasound VevoMD (70 MHz) in ophthalmology
    Trone, M. C.
    Perrot, J. L.
    Grivet, D.
    Cambazard, F.
    Cinotti, E.
    Gain, P.
    Thuret, G.
    ACTA OPHTHALMOLOGICA, 2018, 96 : 127 - 127
  • [43] High-frequency high frame rate ultrasound Imaging system for small animal Imaging with linear Arrays
    Xu, XC
    Hu, CH
    Sun, L
    Yen, J
    Shung, KK
    2005 IEEE ULTRASONICS SYMPOSIUM, VOLS 1-4, 2005, : 1431 - 1434
  • [44] Is My Mouse Pregnant? High-Frequency Ultrasound Assessment
    Phoon, Colin K. L.
    Ren, Mindong
    JOVE-JOURNAL OF VISUALIZED EXPERIMENTS, 2021, (169):
  • [45] High-frequency ultrasound imaging for monitoring the function of meningeal lymphatic system in mice
    Mee-inta, Onanong
    Hsieh, Chin-Fang
    Chen, De-Quan
    Fan, Ching-Hsiang
    Chiang, Yu-Yi
    Liu, Chan-Chuan
    Sze, Chun-, I
    Gean, Po-Wu
    Wu, Ping-Ching
    Yang, Mon-Shieh
    Huang, Po-Sheng
    Wu, Pin Chieh
    Kuo, Yu-Min
    Huang, Chih-Chung
    ULTRASONICS, 2023, 131
  • [46] A low-complexity and high-frequency ASIC transceiver for an ultrasound imaging system
    Lee, Jaeho
    Huh, Keun Young
    Kang, Dongil
    Lim, Jaemyung
    Lee, Byung Chul
    Lee, Byunghun
    BIOMEDICAL ENGINEERING LETTERS, 2024, 14 (06) : 1377 - 1384
  • [47] Skin-scanning technique for superficial blood flow imaging using a high-frequency ultrasound system
    Chen, Jia-Jiun
    Cheng, Chih-Hao
    Yeh, Chih-Kuang
    ULTRASONICS, 2014, 54 (01) : 241 - 246
  • [48] Development of a High-Frequency Ophthalmic Real-Time Ultrasound Imaging System Based on a 20 MHz Annular-Array Transducer
    Wang, Xiaochun
    Li, Zemeng
    Zhou, Sheng
    JOURNAL OF ENGINEERING, 2024, 2024
  • [49] High-speed, high-frequency ultrasound, in utero vector-flow imaging of mouse embryos
    Ketterling, Jeffrey A.
    Aristizabal, Orlando
    Yiu, Billy Y. S.
    Turnbull, Daniel H.
    Phoon, Colin K. L.
    Yu, Alfred C. H.
    Silverman, Ronald H.
    SCIENTIFIC REPORTS, 2017, 7
  • [50] High-speed, high-frequency ultrasound, in utero vector-flow imaging of mouse embryos
    Jeffrey A. Ketterling
    Orlando Aristizábal
    Billy Y. S. Yiu
    Daniel H. Turnbull
    Colin K. L. Phoon
    Alfred C. H. Yu
    Ronald H. Silverman
    Scientific Reports, 7