Comparison of CCS Values Determined by Traveling Wave Ion Mobility Mass Spectrometry and Drift Tube Ion Mobility Mass Spectrometry

被引:92
|
作者
Hinnenkamp, Vanessa [1 ,2 ,3 ]
Klein, Julia [4 ,5 ]
Meckelmann, Sven W. [4 ,5 ]
Balsaa, Peter [1 ]
Schmidt, Torsten C. [1 ,2 ,3 ]
Schmitz, Oliver J. [4 ,5 ]
机构
[1] IWW Water Ctr, Moritzstr 26, D-45476 Mulheim, Germany
[2] Instrumental Analyt Chem, Univ Str 5, D-45141 Essen, Germany
[3] Ctr Water & Environm Res, Univ Str 5, D-45141 Essen, Germany
[4] Univ Duisburg Essen, Appl Analyt Chem, Univ Str 5, D-45141 Essen, Germany
[5] Univ Duisburg Essen, Teaching & Res Ctr Separat, Univ Str 5, D-45141 Essen, Germany
关键词
COLLISION CROSS-SECTION; GAS-PHASE; PROTEIN COMPLEXES; SMALL MOLECULES; STRUCTURAL-CHARACTERIZATION; AMINOBENZOIC ACID; CALIBRATION; DATABASE; PEPTIDE; SEPARATION;
D O I
10.1021/acs.analchem.8b02711
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Collision cross section (CCS, Omega) values determined by ion mobility mass spectrometry (IM-MS) provide the study of ion shape in the gas phase and use of these as further identification criteria in analytical approaches. Databases of CCS values for a variety of molecules determined by different instrument types are available. In this study, the comparability of CCS values determined by a drift tube ion mobility mass spectrometer (DTIM-MS) and a traveling wave ion mobility mass spectrometer (TWIM-MS) was investigated to test if a common database could be used across IM techniques. A total of 124 substances were measured with both systems and CCS values of [M + H](+) and [M + Na](+) adducts were compared. Deviations <1% were found for most substances, but some compounds show deviations up to 6.2%, which indicate that CCS databases cannot be used without care independently from the instrument type. Additionally, it was found that for several molecules [2M + Na](+) ions were formed during electrospray ionization, whereas a part of them disintegrates to [M + Na](+) ions after passing through the drift tube and before reaching the TOF region, resulting in two signals in their drift spectrum for the [M + Na](+) adduct. Finally, the impact of different LC-IM-MS settings (solvent composition, solvent flow rate, desolvation temperature, and desolvation gas flow rate) were investigated to test whether they have an influence on the CCS values or not. The results showed that these conditions have no significant impact. Only for karbutilate changes in the drift spectrum could be observed with different solvent types and flow rates using the DTIM-MS system, which could be caused by the protonation at different sites in the molecule.
引用
收藏
页码:12042 / 12050
页数:9
相关论文
共 50 条
  • [31] Polymers for Traveling Wave Ion Mobility Spectrometry Calibration
    Duez, Quentin
    Chirot, Fabien
    Lienard, Romain
    Josse, Thomas
    Choi, ChangMin
    Coulembier, Olivier
    Dugourd, Philippe
    Cornil, Jerome
    Gerbaux, Pascal
    De Winter, Julien
    JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 2017, 28 (11) : 2483 - 2491
  • [32] Collision cross section calibrants for negative ion mode traveling wave ion mobility-mass spectrometry
    Forsythe, Jay G.
    Petrov, Anton S.
    Walker, Chelsea A.
    Allen, Samuel J.
    Pellissier, Jarrod S.
    Bush, Matthew F.
    Hud, Nicholas V.
    Fernandez, Facundo M.
    ANALYST, 2015, 14 (20) : 6853 - 6861
  • [33] Evaluating the variation of ion energy under different parameter settings in traveling wave ion mobility mass spectrometry
    Mwangi, Joseph N.
    Todd, Daniel A.
    Chiu, Norman H. L.
    INTERNATIONAL JOURNAL FOR ION MOBILITY SPECTROMETRY, 2018, 21 (03) : 81 - 86
  • [34] Traveling wave ion mobility mass spectrometry and ab initio calculations of phosphoric acid clusters
    Lavanant, H. (helene.lavanant@univ-rouen.fr), 1600, Springer Science and Business Media, LLC (25):
  • [35] Traveling Wave Ion Mobility Mass Spectrometry and Ab Initio Calculations of Phosphoric Acid Clusters
    Lavanant, Helene
    Tognetti, Vincent
    Afonso, Carlos
    JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 2014, 25 (04) : 572 - 580
  • [36] Physicochemical property evaluation of modified oligonucleotides by traveling-wave ion mobility mass spectrometry
    Omuro, Shogo
    Yamaguchi, Takao
    Kawase, Taiji
    Terasaki, Maki
    Hirose, Kenji
    Obika, Satoshi
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2022, 36 (10)
  • [37] Diversity in Gold Finger Structure Elucidated by Traveling-Wave Ion Mobility Mass Spectrometry
    Du, Zhifeng
    de Paiva, Raphael E. F.
    Nelson, Kristina
    Farrell, Nicholas P.
    ANGEWANDTE CHEMIE-INTERNATIONAL EDITION, 2017, 56 (16) : 4464 - 4467
  • [38] Self-Assembly and Traveling Wave Ion Mobility Mass Spectrometry Analysis of Hexacadmium Macrocycles
    Chan, Yi-Tsu
    Li, Xiaopeng
    Soler, Monica
    Wang, Jin-Liang
    Wesdemiotis, Chrys
    Newkome, George R.
    JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 2009, 131 (45) : 16395 - +
  • [39] MALDI coupled to modified traveling wave ion mobility mass spectrometry for fast enantiomeric determination
    Nachtigall, Fabiane M.
    Rojas, Moises
    Santos, Leonardo S.
    JOURNAL OF MASS SPECTROMETRY, 2018, 53 (08): : 693 - 699
  • [40] Mobility-Resolved Ion Selection in Uniform Drift Field Ion Mobility Spectrometry/Mass Spectrometry: Dynamic Switching in Structures for Lossless Ion Manipulations
    Webb, Ian K.
    Garimella, Sandilya V. B.
    Tolmachev, Aleksey V.
    Chen, Tsung-Chi
    Zhang, Xinyu
    Cox, Jonathan T.
    Norheim, Randolph V.
    Prost, Spencer A.
    LaMarche, Brian
    Anderson, Gordon A.
    Ibrahim, Yehia M.
    Smith, Richard D.
    ANALYTICAL CHEMISTRY, 2014, 86 (19) : 9632 - 9637