Development and validation of a multiresidue method for the analysis of 151 pesticide residues in strawberry by gas chromatography coupled to a triple quadrupole mass analyzer

被引:52
作者
Plaza Bolanos, Patricia
Luis Fernandez Moreno, Jose
Shtereva, Deyana D.
Garrido Frenich, Antonia [1 ]
Luis Martinez Vidal, Jose
机构
[1] Univ Almeria, Dept Analyt Chem, Almeria 04071, Spain
[2] Plant Protect Inst, Dept Toxicol, Kostinbrod, Bulgaria
关键词
D O I
10.1002/rcm.3091
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A new method was developed and validated for the simultaneous determination of 151 pesticide residues in strawberry by gas chromatography coupled to a triple quadrupole mass analyzer (GC/QqQ-MS/MS), mainly using the selected reaction monitoring (SRM) mode. The list of target compounds included various classes of pesticides such as organochlorine (OCPs), organophosphorus (OPPs), carbamates, pyrethroids, triazoles and dicarboximides. A single extraction of 10 g of sample with acetonitrile followed by liquid-liquid partition formed by the addition of 4 g Of MgSO4 and 1 g of NaCl was applied in sample preparation. Cleanup of the extracts was carried out by applying dispersive solid-phase extraction (D-SPE) with primary secondary amine (PSA). The analysis time was 21 min. The method was subjected to a thorough validation procedure. The recovery data were obtained by spiking blank samples at two concentration levels (11.5 and 50 mu g/kg), yielding recoveries in the range 70-110%. Precision values expressed as relative standard deviation (RSD) were lower than 18% and 22% for the intraday and interday precision, respectively. Linearity was studied in the range 10-200 mu g/kg and determination coefficients (R-2) were higher than 0.98% for all compounds. Limits of detection (LODs) and limits of quantification (LOQs) were established as 4 and 10 mu g/kg, respectively. The overall uncertainty of the method was estimated at two different concentrations (11.5 and 50 mu g/kg), being lower than 25% in both cases. According to the validation data and performance characteristics as well as the high sample throughput and low cost, the proposed method is suitable for routine application. Copyright (C) 2007 John Wiley & Sons, Ltd.
引用
收藏
页码:2282 / 2294
页数:13
相关论文
共 38 条
  • [1] Anastassiades M, 2003, J AOAC INT, V86, P412
  • [2] [Anonymous], SANCO102322006
  • [3] Applications of matrix solid-phase dispersion in food analysis
    Barker, Steven A.
    [J]. Journal of Chromatography A, 2000, 880 (01) : 63 - 68
  • [4] Comparison of pressurized liquid extraction and microwave assisted extraction for the determination of organochlorine pesticides in vegetables
    Barriada-Pereira, M.
    Gonzalez-Castro, M. J.
    Muniategui-Lorenzo, S.
    Lopez-Mahia, P.
    Prada-Rodriguez, D.
    Fernandez-Fernandez, E.
    [J]. TALANTA, 2007, 71 (03) : 1345 - 1351
  • [5] Application of solid-phase microextraction for the determination of pyrethroid residues in vegetable samples by GC-MS
    Beltran, J
    Peruga, A
    Pitarch, E
    López, FJ
    Hernández, F
    [J]. ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2003, 376 (04) : 502 - 511
  • [6] Determination of 266 pesticide residues in apple juice by matrix solid-phase dispersion and gas chromatography-mass selective detection
    Chu, XG
    Hu, XZ
    Yao, HY
    [J]. JOURNAL OF CHROMATOGRAPHY A, 2005, 1063 (1-2) : 201 - 210
  • [7] Assessment of uncertainty in pesticide multiresidue analytical methods:: main sources and estimation
    Cuadros-Rodríguez, L
    Torres, MEH
    López, EA
    González, FJE
    Liébanas, FJA
    Vidal, JLM
    [J]. ANALYTICA CHIMICA ACTA, 2002, 454 (02) : 297 - 314
  • [8] DEHOFFMAN E, 2002, MASS SPECTROMETRY PR, P169
  • [9] Comparison of an acetonitrile extraction/partitioning and "dispersive solid-phase extraction" method with classical multi-residue methods for the extraction of herbicide residues in barley samples
    Diez, C.
    Traag, W. A.
    Zommer, P.
    Marinero, P.
    Atienza, J.
    [J]. JOURNAL OF CHROMATOGRAPHY A, 2006, 1131 (1-2) : 11 - 23
  • [10] European Commission (EC), 2002, Official J. Eur. Commun. No, VL221, P8, DOI DOI 10.1017/CBO9781107415324.004