3D and 2D delayed-enhancement magnetic resonance imaging for detection of myocardial infarction: Preclinical and clinical results

被引:29
作者
Peukert, Daniel
Laule, Michael
Taupitz, Matthias
Kaufels, Nicola
Hamm, Bernd
Dewey, Marc
机构
[1] Humboldt Univ, Dept Radiol, D-10117 Berlin, Germany
[2] Humboldt Univ, Dept Cardiol, D-10117 Berlin, Germany
[3] Humboldt Univ, Charite, D-10117 Berlin, Germany
关键词
myocardial viability; heart; contrast enhancement; magnetic resonance imaging; fast-low angle shot sequence;
D O I
10.1016/j.acra.2007.03.006
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Rationale and Objectives. The purpose was to verify whether myocardial viability can be detected by a delayed enhancement magnetic resonance imaging (MRI) approach using a rapid three-dimensional inversion-recovery fast low-angle shot (3D IR-FLASH) sequence in a preclinical and clinical setting. Materials and Methods. Nonreperfused myocardial infarctions were induced in eight minipigs. Both the pigs and 15 patients with suspected myocardial infarction underwent MRI using a rapid 3D IR-FLASH sequence and a two-dimensional IR-FLASH sequence as the reference standard. Results. In the pigs, a total of 52 segments with myocardial infarction were identified with both sequences and there was good agreement in transmurality of 99.5%. The infarction volume determined with the 3D IR-FLASH in the animal study (2.4 +/- 1.5 cm(3)) showed a good correlation with the histomorphometrically determined volume using triphenyltetrazolium chloride (2.3 +/- 1.2 cm(3), r = 0.98, P < .001) and the two-dimensional IR-FLASH sequence (2.3 +/- 1.4 cm(3), r = 0.99, P < .001). Eleven of 15 patients were found to have myocardial infarction in 37 myocardial segments with both sequences and there was a good agreement in transmurality of 98.8%. There was also a good correlation in the clinical study between the 3D and 2D sequences (6.9 +/- 6.7 cm(3) vs. 6.8 +/- 6.5 cm(3), r = 0.98, P < .001). In Bland-Altman analysis there was no significant under- or overestimation of the myocardial infarction volume using the 3D IR-FLASH sequence in comparison to the two-dimensional reference standard in both the preclinical and clinical study. The contrast-to-noise ratios were not significantly different between 3D and 2D sequences in the animal (34.7 +/- 1.5 vs. 33.8 +/- 2.6; P = .51) and clinical study (31.4 +/- 12.5 vs. 36.7 +/- 11.5; P = .31). The breathhold time for the 3D IR-FLASH sequence in the clinical study (20.4 +/- 2.2 s) was significantly shorter than that of the 2D IR-FLASH sequence (190.1 +/- 20.8 s, P < .001). Conclusions. The rapid 3D IR-FLASH sequence detects myocardial infarction with high accuracy and allows a relevant reduction in acquisition time.
引用
收藏
页码:788 / 794
页数:7
相关论文
共 20 条
[1]   Low-dose gadobenate dimeglumine versus standard-dose gadopentate dimeglumine for delayed contrast-enhanced cardiac magnetic resonance imaging [J].
Balci, NC ;
Inan, N ;
Anik, Y ;
Erturk, MS ;
Ural, D ;
Demirci, A .
ACADEMIC RADIOLOGY, 2006, 13 (07) :833-839
[2]   Imaging of myocardial infarction: Comparison of magnevist and gadophrin-3 in rabbits [J].
Barkhausen, J ;
Ebert, W ;
Debatin, JF ;
Weinmann, HJ .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2002, 39 (08) :1392-1398
[3]   STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1986, 1 (8476) :307-310
[4]  
CARR J, 2003, P INT SOC MAG RESON, V11, P1612
[5]   Standardized myocardial segmentation and nomenclature for tomographic imaging of the heart - A statement for healthcare professionals from the Cardiac Imaging Committee of the Council on Clinical Cardiology of the American Heart Association [J].
Cerqueira, MD ;
Weissman, NJ ;
Dilsizian, V ;
Jacobs, AK ;
Kaul, S ;
Laskey, WK ;
Pennell, DJ ;
Rumberger, JA ;
Ryan, T ;
Verani, MS .
CIRCULATION, 2002, 105 (04) :539-542
[6]   Myocardial viability: Assessment with three-dimensional MR imaging in pigs and patients [J].
Dewey, M ;
Laule, M ;
Taupitz, M ;
Kaufels, N ;
Hamm, B ;
Kivelitz, D .
RADIOLOGY, 2006, 239 (03) :703-709
[7]   Magnetic resonance imaging of myocardial perfusion and viability using a blood pool contrast agent [J].
Dewey, M ;
Kaufels, N ;
Laule, M ;
Schnorr, J ;
Raynaud, JS ;
Hamm, B ;
Taupitz, M .
INVESTIGATIVE RADIOLOGY, 2004, 39 (08) :498-505
[8]   Late gadolinium cardiovascular magnetic resonance in the assessment of myocardial viability [J].
Elliott, MD ;
Kim, RJ .
CORONARY ARTERY DISEASE, 2005, 16 (06) :365-372
[9]   Myocardial viability: Breath-hold 3D MR imaging of delayed hyperenhancement with variable sampling in time [J].
Foo, TKF ;
Stanley, DW ;
Castillo, E ;
Rochitte, CE ;
Wang, Y ;
Lima, JAC ;
Bluemke, DA ;
Wu, KC .
RADIOLOGY, 2004, 230 (03) :845-851
[10]   Temporal trends in coronary heart disease mortality and sudden cardiac death from 1950 to 1999 - The Framingham Heart Study [J].
Fox, CS ;
Evans, JC ;
Larson, MG ;
Kannel, WB ;
Levy, D .
CIRCULATION, 2004, 110 (05) :522-527