VOID FRACTION MEASUREMENTS FOR AIR-WATER PIPE FLOWS USING QUICK CLOSING VALVES AND WIRE-MESH SENSORS

被引:0
|
作者
Lessard, Etienne [1 ]
Yang, Jun [1 ]
机构
[1] Canadian Nucl Labs, 286 Plant Rd,Stn 87, Chalk River, ON K0J 1J0, Canada
来源
PROCEEDINGS OF THE ASME FLUIDS ENGINEERING DIVISION SUMMER MEETING, 2018, VOL 2 | 2018年
关键词
wire-mesh sensors; quick-closing valves; void fraction; two-phase flow; multiphase flow; TOMOGRAPH;
D O I
暂无
中图分类号
TH [机械、仪表工业];
学科分类号
0802 ;
摘要
In support of a header/feeder phenomena study, an adiabatic, near-atmospheric, air-water flow loop was commissioned simulating a single feeder of a Pressurized Heavy Water Reactor's primary heat transport system under a postulated Loss of Coolant Accident scenario. An extensive database in representative two-phase flow conditions was collected, 750 tests in total, in order to create a two-phase flow map to be used in the more complex geometries such as header/feeder systems. The flow loop consists of two vertical test sections, for upwards and downwards flow, and one horizontal test section, each with an inner diameter of 32 mm and at least 120 diameters in length. Superficial velocities extended up to 6 m/s for the water and 10 m/s for the air. Void fraction was measured by means of quick-closing valves and a pair of wire-mesh sensors (WMS) in each test section. Two-phase repeatability tests showed that the liquid and gas superficial velocities varied by 1.1% and 0.6% at reference conditions of 2.0 and 2.8 m/s, respectively. The corresponding void fraction measurements varied for the quick-closing valves by at most 6.8%, which indicates a low sensitivity to the closure time of the valves and an appropriate axial distance between them, and 2.3% for the WMS. For both measurement techniques, the largest variations occurred in the vertical downwards test section. For the formal two-phase tests, over 600 distinct flow conditions were performed. The results showed that the two measurement techniques agreed within 5% at high void fractions and low liquid flow rates in vertical flow. For all other cases corresponding to the transitional or dispersed bubbly flow regime, the WMS over-estimated the void fraction by a consistent bias. An empirical correction is proposed, with a root-mean-square error of 6.6% across all tests. The void fraction map resulting from this database provides validation for the WMS measurements, a quantitative assessment of its uncertainty and range of applicability, and will be used as a reference in future tests under similar scale and flow conditions.
引用
收藏
页数:8
相关论文
共 45 条
  • [1] UNCERTAINTY QUANTIFICATION OF LOW VOID FRACTION MEASUREMENTS USING WIRE-MESH SENSORS IN HORIZONTAL AIR-WATER FLOWS
    Lessard, Etienne M.
    Bowden, Robert C.
    Yang, Sun-Kyu
    PROCEEDINGS OF THE ASME FLUIDS ENGINEERING DIVISION SUMMER MEETING, 2016, VOL 2: FORA, 2016,
  • [2] Measurement of air distribution and void fraction of an upwards air-water flow using electrical resistance tomography and a wire-mesh sensor
    Olerni, Claudio
    Jia, Jiabin
    Wang, Mi
    MEASUREMENT SCIENCE AND TECHNOLOGY, 2013, 24 (03)
  • [3] Experimental investigation on the void fraction characteristics of a sudden expansion tube using wire-mesh sensors
    Liang, Fachun
    Wang, Sigang
    Meng, Jia
    Xin, Lingqi
    Zhao, Jingwen
    FLOW MEASUREMENT AND INSTRUMENTATION, 2022, 87
  • [4] Evolution of interfacial area concentration in a vertical air-water flow measured by wire-mesh sensors
    Prasser, Horst-Michael
    NUCLEAR ENGINEERING AND DESIGN, 2007, 237 (15-17) : 1608 - 1617
  • [5] CHARACTERISATION OF AIR-WATER TWO-PHASE FLOW USING A WIRE-MESH SENSOR
    do Amaral, Carlos E. F.
    Scorsim, Oliver B. S.
    Santos, Eduardo N.
    da Silva, Marco Jose
    Conte, Marco Germano
    Morales, Rigoberto E. M.
    PROCEEDINGS OF THE ASME INTERNATIONAL MECHANICAL ENGINEERING CONGRESS AND EXPOSITION, 2011, VOL 6, PTS A AND B, 2012, : 695 - 702
  • [6] A Wire-Mesh Sensor for Air-Water Two-Phase Flow Imaging
    Liu, Weiling
    Tan, Chao
    Dong, Feng
    2015 IEEE INTERNATIONAL INSTRUMENTATION AND MEASUREMENT TECHNOLOGY CONFERENCE (I2MTC), 2015, : 364 - 369
  • [7] Void fraction measurements of bubbly flow in a horizontal 90° bend using wire mesh sensors
    Bowden, Robert C.
    Lessard, Etienne
    Yang, Sun-Kyu
    INTERNATIONAL JOURNAL OF MULTIPHASE FLOW, 2018, 99 : 30 - 47
  • [8] Slug flow regime identification from dynamic void fraction measurements in vertical air-water flows
    Costigan, G
    Whalley, PB
    INTERNATIONAL JOURNAL OF MULTIPHASE FLOW, 1997, 23 (02) : 263 - 282
  • [9] Quality check of wire-mesh sensor measurements in a vertical air/water flow
    Beyer, Matthias
    Lucas, Dirk
    Kussin, Johannes
    FLOW MEASUREMENT AND INSTRUMENTATION, 2010, 21 (04) : 511 - 520
  • [10] Performance of electrochemical probes for local void fraction measurement in air-water flows
    Timkin, LS
    Rivière, N
    Cartellier, A
    Kashinsky, ON
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2003, 74 (08): : 3784 - 3786