Fully implantable hearing aid in the incudostapedial joint gap

被引:10
作者
Koch, Martin [1 ]
Essinger, Till Moritz [1 ]
Stoppe, Thomas [1 ]
Lasurashvili, Nikoloz [1 ]
Bornitz, Matthias [1 ]
Zahnert, Thomas [1 ]
机构
[1] Tech Univ Dresden, Fac Med Carl Gustav Carus, Otorhinolaryngol, Fetscherstr 74,Haus 5, D-01307 Dresden, Germany
关键词
Middle ear implant; Incudostapedial joint gap; Middle ear; Fully implantable; Sensor; Actuator; Piezoelectricity; MIDDLE-EAR IMPLANT; ROUND-WINDOW STIMULATION; DEVICE; MODEL; RECONSTRUCTION; SIMULATION; SYSTEM;
D O I
10.1016/j.heares.2016.03.015
中图分类号
R36 [病理学]; R76 [耳鼻咽喉科学];
学科分类号
100104 ; 100213 ;
摘要
A fully implantable hearing aid is introduced which is a combined sensor-actuator-transducer designed for insertion into the incudostapedial joint gap (ISJ). The active elements each consist of a thin titanium membrane with an applied piezoelectric single crystal. The effectiveness of the operating principle is verified in a temporal bone study. We also take a closer look at the influence of an implantation-induced increase in middle ear stiffness on the transducer's output. An assembly of the transducer with 1 mm thickness is built and inserted into six temporal bones. At this thickness, the stiffness of the annular ligament is considerably increased, which leads to a loss in functional gain for the transducer. It is assumed that a thinner transducer would reduce this effect. In order to examine the performance for a prospective reduced pretension, we increased the gap size at the ISJ by 0.5 mm by removing the capitulum of the stapes in four temporal bones. The TM is stimulated with a broadband multisine sound signal in the audiological frequency range. The movement of the stapes footplate is measured with a laser Doppler vibrometer. The sensor signal is digitally processed and the amplified signal drives the actuator. The resulting feedback is minimized by an active noise control least mean square (LMS) algorithm which is implemented on a field programmable gate array. The dynamic range and the functional gain of the transducer in the temporal bones are determined. The results are compared to measurements from temporal bones without ISJ extension and to the results of Finite Elements Model (FE model) simulations. In the frequency range above 2 kHz a functional gain of 30 dB and more is achieved. This proposes the transducer as a potential treatment for high frequency hearing loss, e.g. for patients with noise-induced hearing loss. The transducer offers sufficient results for a comprehensive application. Adaptations in the transducer design or surgical approach are necessary to cope with ligament stiffening issues. These cause insufficient performance for low frequencies under 1 kHz. (C) 2016 Elsevier B.V. All rights reserved.
引用
收藏
页码:169 / 178
页数:10
相关论文
共 41 条
[1]  
Amlani Amyn M, 2002, Trends Amplif, V6, P81, DOI 10.1177/108471380200600302
[2]  
ASTM, 2005, STAND PRACT DESCR SY, V68, P71
[3]  
Ball G R, 1997, Ear Nose Throat J, V76, P213
[4]  
Beutner D, 2009, LARYNGO RHINO OTOL, V88, P32
[5]   Active Middle Ear Implant Compared With Open-Fit Hearing Aid in Sloping High-Frequency Sensorineural Hearing Loss [J].
Boeheim, Klaus ;
Pok, Stefan-Marcel ;
Schloegel, Max ;
Filzmoser, Peter .
OTOLOGY & NEUROTOLOGY, 2010, 31 (03) :424-429
[6]   Evaluation of implantable actuators by means of a middle ear simulation model [J].
Bornitz, Matthias ;
Hardtke, Hans-Juergen ;
Zahnert, Thomas .
HEARING RESEARCH, 2010, 263 (1-2) :145-151
[7]  
Bruschini L, 2009, ACTA OTORHINOLARYNGO, V29, P79
[8]   Phase 1 clinical trial results of the envoy system: A totally implantable middle ear device for sensorineural hearing loss [J].
Chen, DA ;
Backous, DD ;
Arriaga, MA ;
Garvin, R ;
Kobylek, D ;
Littman, T ;
Walgren, S ;
Lura, D .
OTOLARYNGOLOGY-HEAD AND NECK SURGERY, 2004, 131 (06) :904-916
[9]   Implantable hearing aids [J].
Counter, P. .
PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART H-JOURNAL OF ENGINEERING IN MEDICINE, 2008, 222 (H6) :837-852
[10]   Techniques to Improve the Efficiency of a Middle Ear Implant: Effect of Different Methods of Coupling to the Ossicular Chain [J].
Deveze, Arnaud ;
Koka, Kanthaiah ;
Tringali, Stephane ;
Jenkins, Herman A. ;
Tollin, Daniel J. .
OTOLOGY & NEUROTOLOGY, 2013, 34 (01) :158-166