The optimum sevoflurane concentration for supraglottic airway device Blockbuster™ insertion with spontaneous breathing in obese patients: a prospective observational study

被引:13
|
作者
Wang, Haixia [1 ]
Gao, Xue [1 ]
Wei, Wei [1 ]
Miao, Huihui [1 ]
Meng, Hua [2 ]
Tian, Ming [1 ]
机构
[1] Capital Med Univ, Beijing Friendship Hosp, Dept Anesthesiol, Beijing, Peoples R China
[2] Capital Med Univ, Beijing Friendship Hosp, Dept Gen Surg, Beijing, Peoples R China
来源
BMC ANESTHESIOLOGY | 2017年 / 17卷
关键词
Obesity; Spontaneous breathing; Sevoflurane; Supraglottic airway device; LARYNGEAL MASK AIRWAY; I-GEL INSERTION; MORBIDLY OBESE; TRACHEAL INTUBATION; PROPOFOL; DIFFICULT; REMIFENTANIL; MANAGEMENT; DESFLURANE; INDUCTION;
D O I
10.1186/s12871-017-0449-5
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
Background: Airway management of the obese patient presenting for surgery is more likely to be a challenging problem. Supraglottic airway device has been adopted as a bridge to connect ventilation and tracheal intubation in obese patients who would be suffered with difficult intubation. The optimum sevoflurane concentration for supraglottic airway device insertion allowing spontaneous breathing in 50% of obese patients (ED50) is not known. The purpose of this study was to determine the ED50 of sevoflurane for supraglottic airway device Blockbuster (TM) insertion with spontaneous breathing in obese patients requiring general anesthesia. Methods: Thirty elective obese patients (body mass index 30-50 kg/m(2)) undergoing bariatric surgery were recruited in this study. The predetermined target sevoflurane concentration (initiating at 2.5% with 0.5% as a step size) was sustained for >5 min using a modified Dixon's up-and-down method, and then the supraglottic airway device lockbuster (TM) was inserted. The patient's response to supraglottic airway device insertion was classified as either 'movement' or 'no-movement'. The ED50 of sevoflurane were determined by calculating the midpoint concentration of crossover point from 'movement' or 'no-movement' response. Results: The ED50 of sevoflurane for supraglottic airway device Blockbuster (TM) insertion in obese patients calculated using up-and-down method were 2.50 +/- 0.60%. The ED50 and ED95 (95% confidence interval) obtained by probit regression analysis were 2.35 (1.28-3.42) % and 4.03 (3.16-17.83) % for supraglottic airway device Blockbuster (TM) insertion, respectively. Conclusion: We conclude that the optimum end-tidal sevoflurane concentration required for the supraglottic airway device Blockbuster (TM) insertion allowing spontaneous breathing in 50% of obese patients (ED50) is 2.5 +/- 0.6%.
引用
收藏
页数:9
相关论文
共 17 条
  • [1] The optimum sevoflurane concentration for supraglottic airway device Blockbuster™ insertion with spontaneous breathing in obese patients: a prospective observational study
    Haixia Wang
    Xue Gao
    Wei Wei
    Huihui Miao
    Hua Meng
    Ming Tian
    BMC Anesthesiology, 17
  • [2] Optimum end-tidal concentration of sevoflurane to facilitate supraglottic airway device insertion with propofol at induction allowing spontaneous respiration in obese patients A prospective observational study
    Wang, Hai-Xia
    Miao, Hui-Hui
    Gao, Xue
    Wei, Wei
    Ding, Guan-Nan
    Zhang, Ye
    Tian, Ming
    MEDICINE, 2017, 96 (47)
  • [3] Dexmedetomidine reduces sevoflurane EC50 for supraglottic airway device insertion in spontaneously breathing morbidly obese patients
    Wan, Lei
    Shao, Liu-Jia-Zi
    Liu, Yang
    Wang, Hai-Xia
    Xue, Fu-Shan
    Tian, Ming
    THERAPEUTICS AND CLINICAL RISK MANAGEMENT, 2019, 15 : 627 - 635
  • [4] A feasibility study of jaw thrust as an indicator assessing adequate depth of anesthesia for insertion of supraglottic airway device in morbidly obese patients
    Wan, Lei
    Shao, Liu-Jia-Zi
    Liu, Yang
    Wang, Hai-Xia
    Xue, Fu-Shan
    Tian, Ming
    CHINESE MEDICAL JOURNAL, 2019, 132 (18) : 2185 - 2191
  • [5] Fiberoptic-guided intubation after insertion of the i-gel airway device in spontaneously breathing patients with difficult airway predicted: a prospective observational study
    Arevalo-Ludena, Julian
    Juan Arcas-Bellas, Jose
    Alvarez-Rementeria, Rafael
    Munoz Alameda, Luis Enrique
    JOURNAL OF CLINICAL ANESTHESIA, 2016, 35 : 287 - 292
  • [6] A feasibility study of jaw thrust as an indicator assessing adequate depth of anesthesia for insertion of supraglottic airway device in morbidly obese patients
    Wan Lei
    Shao Liu-Jia-Zi
    Liu Yang
    Wang Hai-Xia
    Xue Fu-Shan
    Tian Ming
    中华医学杂志英文版, 2019, 132 (18) : 2185 - 2191
  • [7] Temporomandibular joint dysfunction following the use of a supraglottic airway device during general anaesthesia: a prospective observational study
    Akhtar, N.
    Ungureanu, N.
    Cakir, S.
    Ansari, U.
    Mohamed, T-Y
    Brown, K.
    Stocker, J.
    Mendonca, C.
    ANAESTHESIA, 2021, 76 (11) : 1511 - 1517
  • [8] Predicted end-tidal sevoflurane concentration for insertion of a Laryngeal Mask Supreme A prospective observational study
    Zaballos, Matilde
    Bastida, Emilia
    Jimenez, Consolacion
    Agusti, Salome
    Teresa Lopez-Gil, M.
    EUROPEAN JOURNAL OF ANAESTHESIOLOGY, 2013, 30 (04) : 170 - 174
  • [9] Efficiency of I-gel supraglottic airway device during mechanical ventilation in supin and lateral decubitus position in obese patient; prospective observational study
    Farouk, Inas
    Abdelhamid, Bassant Mohamed
    Wishahy, Mohamed Kadry
    Mohamed, Hassan
    Hassan, Mohamed Mahmoud
    EGYPTIAN JOURNAL OF ANAESTHESIA, 2020, 36 (01): : 126 - 133
  • [10] COMPARISON OF NEUROLOGICAL OUTCOME BETWEEN TRACHEAL INTUBATION AND SUPRAGLOTTIC AIRWAY DEVICE INSERTION OF OUT-OF-HOSPITAL CARDIAC ARREST PATIENTS: A NATIONWIDE, POPULATION-BASED, OBSERVATIONAL STUDY
    Tanabe, Seizan
    Ogawa, Toshio
    Akahane, Manabu
    Koike, Soichi
    Horiguchi, Hiromasa
    Yasunaga, Hideo
    Mizoguchi, Tatsuhiro
    Hatanaka, Tetsuo
    Yokota, Hiroyuki
    Imamura, Tomoaki
    JOURNAL OF EMERGENCY MEDICINE, 2013, 44 (02) : 389 - 397