Determination of biochemical species on electrophoresis chips with an external contactless conductivity detector

被引:53
作者
Abad-Villar, EM [1 ]
Kubán, P [1 ]
Hauser, PC [1 ]
机构
[1] Univ Basel, Dept Chem, CH-4004 Basel, Switzerland
关键词
amino acids; contactless conductivity detection; DNA; electrophoresis chip; enzymatic digestion; immunoglobulin G; peptides; peptide map; proteins; proteomics; systems biology;
D O I
10.1002/elps.200500149
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Contactless conductivity measurements were found to be suitable for the direct detection, i.e., without needing any labels, of a range of biochemically relevant species, namely amino acids, peptides, proteins, immunoglobulin, and DNA. It was also possible to monitor the products of the enzymatic digestion of HSA with pepsin. Detection was carried out on bare electrophoresis chips made from poly(methyl methacrylate) by probing the conductivity in the channel with a pair of external electrodes, which are fixed on the chip holder. Separation efficiencies up to 15 000 plates could be obtained and LODs are in the low mu m-range, except for immunoglobulin G (IgG) which could be determined down to 0.4 nM. Linear dynamic ranges of two to three orders of magnitude were obtained for the peptides as examples.
引用
收藏
页码:3609 / 3614
页数:6
相关论文
共 38 条
[1]   Detection of human immunoglobulin in microchip and conventional capillary electrophoresis with contactless conductivity measurements [J].
Abad-Villar, EM ;
Tanyanyiwa, J ;
Fernández-Abedul, MT ;
Costa-García, A ;
Hauser, PC .
ANALYTICAL CHEMISTRY, 2004, 76 (05) :1282-1288
[2]   Protein microchips: Use for immunoassay and enzymatic reactions [J].
Arenkov, P ;
Kukhtin, A ;
Gemmell, A ;
Voloshchuk, S ;
Chupeeva, V ;
Mirzabekov, A .
ANALYTICAL BIOCHEMISTRY, 2000, 278 (02) :123-131
[3]   Biochemical analysis with microfluidic systems [J].
Bilitewski, U ;
Genrich, M ;
Kadow, S ;
Mersal, G .
ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2003, 377 (03) :556-569
[4]   Quantitative studies on the adsorption of proteins to the bare silica wall in capillary electrophoresis III: Effects of adsorbed surfactants on quenching the interaction [J].
Castelletti, L ;
Verzola, B ;
Gelfi, C ;
Stoyanov, A ;
Righetti, PG .
JOURNAL OF CHROMATOGRAPHY A, 2000, 894 (1-2) :281-289
[5]   Separation of twenty underivatized essential amino acids by capillary zone electrophoresis with contactless conductivity detection [J].
Coufal, P ;
Zuska, J ;
van de Goor, T ;
Smith, V ;
Gas, B .
ELECTROPHORESIS, 2003, 24 (04) :671-677
[6]   Separation of proteins on surface-modified poly(dimethylsiloxane) microfluidic devices [J].
Dou, YH ;
Bao, N ;
Xu, JJ ;
Meng, F ;
Chen, HY .
ELECTROPHORESIS, 2004, 25 (17) :3024-3031
[7]  
Dou YH, 2002, ELECTROPHORESIS, V23, P3558, DOI 10.1002/1522-2683(200210)23:20<3558::AID-ELPS3558>3.0.CO
[8]  
2-#
[9]   High-resolution DNA separation in microcapillary electrophoresis chips utilizing double-L injection techniques [J].
Fu, LM ;
Lin, CH .
ELECTROPHORESIS, 2004, 25 (21-22) :3652-3659
[10]   Cationic starch derivatives as dynamic coating additives for analysis of amino acids and peptides using poly(methyl methacrylate) microfluidic devices [J].
Kato, M ;
Gyoten, Y ;
Sakai-Kato, K ;
Nakajima, T ;
Toyo'oka, T .
ANALYTICAL CHEMISTRY, 2004, 76 (22) :6792-6796