Design and control of grid connected inverter for harmonic suppression

被引:0
|
作者
Fei, Congliang [1 ]
Xiahou, Pengfei [1 ]
Wang, Fujun [1 ]
机构
[1] Jiangsu Elect Power, Jinhu Branch, Huaian, Jinhu County, Peoples R China
关键词
Distributed generation; Harmonic suppression; Grid connected inverter; PI control algorithm; POWER; COMPENSATION; FILTERS;
D O I
10.1108/JEDT-11-2019-0285
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
Purpose This study aims to focus on the grid connected inverter. Design/methodology/approach The grid connected inverter for harmonic suppression was designed, the topological structure of the inverter and the design of LCL filter were analyzed, then a PIR controller was proposed and finally simulation and experiment were carried out. Findings The simulation results showed that the distortion rates of the 5th, 7th and 11th harmonics under PIR control were 0.14%, 0.13% and 0.06%, respectively, which were significantly lower than that under PI control. The system test results also showed that the current waveform under PI control was rough and total harmonic distortion (THD) content was 3.8%; under PIR control, the grid connected current waveform was relatively smooth, with fewer spikes and burrs, and the THD content was 1.9%, indicating that the harmonics were effectively suppressed. Originality/value The experimental results verify that the inverter and PIR controller designed in this study are effective for harmonic suppression. This work makes some contributions to the improvement of the effect of harmonic suppression and promotion of the better application of grid connected inverter.
引用
收藏
页码:1349 / 1356
页数:8
相关论文
共 50 条
  • [31] Frequency Adaptive Selective Harmonic Control for Grid-Connected Inverters
    Yang, Yongheng
    Zhou, Keliang
    Wang, Huai
    Blaabjerg, Frede
    Wang, Danwei
    Zhang, Bin
    IEEE TRANSACTIONS ON POWER ELECTRONICS, 2015, 30 (07) : 3912 - 3924
  • [32] Online Parameter Optimization Method of Harmonic Controller for Grid-Connected Inverter
    Tang, Jian
    Zou, Zhixiang
    Liu, Xingqi
    Zhang, Yi
    Xu, Ruokai
    Wang, Yuchen
    Hua, Wei
    2022 IEEE ENERGY CONVERSION CONGRESS AND EXPOSITION (ECCE), 2022,
  • [33] Design of a Seamless Grid-Connected Inverter for Microgrid Applications
    Lo, Kuo-Yuan
    Chen, Yaow-Ming
    IEEE TRANSACTIONS ON SMART GRID, 2020, 11 (01) : 194 - 202
  • [34] A Method of Harmonic Current Suppression in Photovoltaic Grid-connected Systems
    Guo, Jia
    Li, Zhigang
    Cheng, Yaping
    Huang, Kai
    Cui, Chunyan
    SENSORS, MEASUREMENT AND INTELLIGENT MATERIALS, PTS 1-4, 2013, 303-306 : 1145 - 1148
  • [35] Harmonic Voltage Compensation Control Strategy for Droop-Controlled Inverter in Islanded/Grid-connected Mode
    Zhang, Chunxue
    Li, Canbing
    Li, Fei
    Sun, Kai
    Feng, Wei
    2017 CHINESE AUTOMATION CONGRESS (CAC), 2017, : 6892 - 6897
  • [36] The Control for Grid Connected Inverter of Distributed Generation under Unbalanced Grid Voltage
    Zhang Guowei
    Wei Tongzhen
    Huang Shengli
    Kong Lingzhi
    2009 INTERNATIONAL CONFERENCE ON SUSTAINABLE POWER GENERATION AND SUPPLY, VOLS 1-4, 2009, : 876 - +
  • [37] Analysis and Suppression of Harmonic Resonance in Photovoltaic Grid-Connected Systems
    Zhu, Tong
    Huang, Gechao
    Ouyang, Xuetong
    Zhang, Weilin
    Wang, Yanfeng
    Ye, Xi
    Wang, Yuhong
    Gao, Shilin
    ENERGIES, 2024, 17 (05)
  • [38] Control Design of LCL Type Grid-Connected Inverter Based on State Feedback Linearization
    Yang, Longyue
    Feng, Chunchun
    Liu, Jianhua
    ELECTRONICS, 2019, 8 (08)
  • [39] Harmonic Suppression Mechanism Analysis for Wind Power Grid-connected Converter and Research on Control Strategy
    Meng Yanfeng
    Hu Shuju
    Xu Honghua
    PROCEEDINGS OF 2017 CHINA INTERNATIONAL ELECTRICAL AND ENERGY CONFERENCE (CIEEC 2017), 2017, : 263 - 268
  • [40] Fault Ride Through Control of Three-phase grid-connected Inverter Under Harmonic and Unbalanced Grid Voltage Conditions
    Guo X.
    Liu W.
    1600, Chinese Society for Electrical Engineering (37): : 5118 - 5124