Ring-reinforced prosthesis for paracolostomy hernia

被引:18
作者
de Ruiter, P
Bijnen, AB
机构
[1] Med Ctr Alkmaar, Dept Surg, NL-1815 JD Alkmaar, Netherlands
[2] Free Univ Amsterdam, Med Ctr, Inst Med Educ, Amsterdam, Netherlands
关键词
parastomal hernia; polypropylene ring; polypropylene mesh prosthesis; rectus abdominis muscle;
D O I
10.1159/000087147
中图分类号
R57 [消化系及腹部疾病];
学科分类号
摘要
Background: The reported recurrence rate after paracolostomy hernia repair, with or without mesh, varies between 47 and 100%. We developed a polypropylene mesh prosthesis with a central opening, reinforced with a polypropylene ring, that can be implanted suprafascially through a mucocutaneous incision. Methods: The results of a consecutive series of 46 patients with paracolostomy hernia, who were implanted with this prosthesis between October 1988 and November 2000 in 12 hospitals, were analyzed. The mean follow-up was 5 (range 1-13) years. Results: The early infection rate was 4.3%. Two patients were lost to follow-up. The late infection rate was 2.3%. Seven patients (15.9%) developed a recurrent parastomal hernia and were all reoperated. The prosthesis was definitively removed in 10 patients. Conclusion: Although implantation of this new prosthesis is not without complications, it offers the lowest reported recurrence rate until now. Copyright (c) 2005 S. Karger AG, Basel.
引用
收藏
页码:152 / 156
页数:5
相关论文
共 16 条
  • [1] SURGICAL-TREATMENT OF COLOSTOMY COMPLICATIONS
    ALLENMERSH, TG
    THOMSON, JPS
    [J]. BRITISH JOURNAL OF SURGERY, 1988, 75 (05) : 416 - 418
  • [2] Colonic parastomal hernia repair by translocation without formal laparotomy
    Botet, X
    Boldo, E
    Llaurado, JM
    [J]. BRITISH JOURNAL OF SURGERY, 1996, 83 (07) : 981 - 981
  • [3] Parastomal hernia
    Carne, PWG
    Robertson, GM
    Frizelle, FA
    [J]. BRITISH JOURNAL OF SURGERY, 2003, 90 (07) : 784 - 793
  • [4] Surgical treatment of parastomal hernia complicating sigmoid colostomies
    Cheung, MT
    Chia, NH
    Chiu, WY
    [J]. DISEASES OF THE COLON & RECTUM, 2001, 44 (02) : 266 - 270
  • [5] ELDRUP J, 1962, UGESKRIFT LAEGER, V144, P3742
  • [6] LIFE TABLE ANALYSIS OF STOMAL COMPLICATIONS FOLLOWING COLOSTOMY
    LONDONOSCHIMMER, EE
    LEONG, APK
    PHILLIPS, RKS
    [J]. DISEASES OF THE COLON & RECTUM, 1994, 37 (09) : 916 - 920
  • [7] Morris-Stiff G, 1998, ANN ROY COLL SURG, V80, P184
  • [8] DOES THE FREQUENCY OF PARACOLOSTOMY HERNIAS DEPEND ON THE POSITION OF THE COLOSTOMY IN THE ABDOMINAL-WALL
    ORTIZ, H
    SARA, MJ
    ARMENDARIZ, P
    DEMIGUEL, M
    MARTI, J
    CHOCARRO, C
    [J]. INTERNATIONAL JOURNAL OF COLORECTAL DISEASE, 1994, 9 (02) : 65 - 67
  • [9] ROBSON W, 1964, SURG GYNECOL OBSTET, V118, P1234
  • [10] PARACOLOSTOMY HERNIA REPAIR WITH MARLEX MESH - NEW TECHNIQUE
    ROSIN, JD
    BONARDI, RA
    [J]. DISEASES OF THE COLON & RECTUM, 1977, 20 (04) : 299 - 302