Robust design for acetabular cup stability accounting for patient and surgical variability

被引:10
|
作者
Ong, Kevin L. [1 ]
Santner, Thomas J. [2 ]
Bartel, Donald L. [3 ]
机构
[1] Exponent Inc, Philadelphia, PA 19104 USA
[2] Ohio State Univ, Dept Stat, Columbus, OH 43210 USA
[3] Cornell Univ, Sibley Sch Mech & Aerosp Engn, Ithaca, NY 14853 USA
来源
JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME | 2008年 / 130卷 / 03期
基金
美国国家科学基金会;
关键词
robust analysis; total hip arthroplasty; acetabular cup; stability; cementless;
D O I
10.1115/1.2907764
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
The stability of cementless acetabular cups depends on a close fit between the components and reamed acetabular cavities to promote bone ingrowth. Cup performance and stability are affected by both design and environmental (patient-dependent and surgical) factors. This study used a statistically based metamodel to determine the relative influences of design and environmental factors on acetabular cup stability by incorporating a comprehensive set of patient-dependent and surgical variables. Cup designs with 2 mm or 3 mm intended equatorial bone-implant interferences appeared to perform the best, improving implant stability with smaller mean and variability in cup relative motions and greater mean and smaller variability in ingrowth areas. Cup eccentricity was found to have no effect on implant performance. Design variables did not contribute as much to the variation in performance measures compared to the environmental variables, except for potential ingrowth areas.
引用
收藏
页数:11
相关论文
共 50 条
  • [41] Does Cup-cage Reconstruction With Oversized Cups Provide Initial Stability in THA for Osteoporotic Acetabular Fractures?
    Solomon, Lucian B.
    Studer, Patrick
    Abrahams, John M.
    Callary, Stuart A.
    Moran, Caroline R.
    Stamenkov, Roumen B.
    Howie, Donald W.
    CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2015, 473 (12) : 3811 - 3819
  • [42] Precision of radiostereometric analysis (RSA) of acetabular cup stability and polyethylene wear improved by adding tantalum beads to the liner
    Nebergall, Audrey K.
    Rader, Kevin
    Palm, Henrik
    Malchau, Henrik
    Greene, Meridith E.
    ACTA ORTHOPAEDICA, 2015, 86 (05) : 563 - 568
  • [43] 3D Printed Patient-Specific Acetabular Jig for Cup Placement in Total Hip Arthroplasty
    Abhishek Mishra
    Tarun Verma
    Gaurang Rajkumar
    Amit Agarwal
    Lalit Sharma
    Indian Journal of Orthopaedics, 2020, 54 : 174 - 180
  • [44] 3D Printed Patient-Specific Acetabular Jig for Cup Placement in Total Hip Arthroplasty
    Mishra, Abhishek
    Verma, Tarun
    Rajkumar
    Agarwal, Gaurang
    Sharma, Amit
    Maini, Lalit
    INDIAN JOURNAL OF ORTHOPAEDICS, 2020, 54 (02) : 174 - 180
  • [45] Use of Computer Navigation for Optimal Acetabular Cup Placement in Revision Total Hip Arthroplasty: Case Reports and Surgical Techniques
    Neitzke, Anna Colin C.
    Chandi, Sonia K.
    Gausden, Elizabeth B.
    Debbi, Eytan M.
    Sculco, Peter K.
    Chalmers, Brian P.
    ARTHROPLASTY TODAY, 2024, 27
  • [46] The role of muscle forces and gait cycle discretization when assessing acetabular cup primary stability: A finite element study
    Fallahnezhad, Khosro
    O'Rourke, Dermot
    Bahl, Jasvir S.
    Thewlis, Dominic
    Taylor, Mark
    COMPUTER METHODS AND PROGRAMS IN BIOMEDICINE, 2023, 230
  • [47] Stability Based Robust Eigenvalue Design for Tolerance
    Lu, XinJiang
    Li, Han-Xiong
    JOURNAL OF MECHANICAL DESIGN, 2009, 131 (08) : 0810071 - 0810077
  • [48] Letter to the Editor: The Effect of Postural Pelvic Dynamics on the Three-dimensional Orientation of the Acetabular Cup in THA Is Patient Specific
    Zhao, Jing-Xin
    Su, Xiu-Yun
    Zhao, Zhe
    Zhang, Li-Cheng
    Tang, Pei-Fu
    CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2021, 479 (08) : 1871 - 1872
  • [49] CORR Insights®: The Effect of Postural Pelvic Dynamics on the Three-dimensional Orientation of the Acetabular Cup in THA Is Patient Specific
    Tanino, Hiromasa
    CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2021, 479 (03) : 572 - 574
  • [50] Inter- and intra-observer variability of radiography and computed tomography for evaluation of Zurich cementless acetabular cup placement ex vivo
    Leasure, Jessica O.
    Peck, Jeffrey N.
    Villamil, Armando
    Fiore, Kara L.
    Tano, Cheryl A.
    VETERINARY AND COMPARATIVE ORTHOPAEDICS AND TRAUMATOLOGY, 2016, 29 (06) : 507 - 514