Robust design for acetabular cup stability accounting for patient and surgical variability

被引:10
|
作者
Ong, Kevin L. [1 ]
Santner, Thomas J. [2 ]
Bartel, Donald L. [3 ]
机构
[1] Exponent Inc, Philadelphia, PA 19104 USA
[2] Ohio State Univ, Dept Stat, Columbus, OH 43210 USA
[3] Cornell Univ, Sibley Sch Mech & Aerosp Engn, Ithaca, NY 14853 USA
来源
JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME | 2008年 / 130卷 / 03期
基金
美国国家科学基金会;
关键词
robust analysis; total hip arthroplasty; acetabular cup; stability; cementless;
D O I
10.1115/1.2907764
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
The stability of cementless acetabular cups depends on a close fit between the components and reamed acetabular cavities to promote bone ingrowth. Cup performance and stability are affected by both design and environmental (patient-dependent and surgical) factors. This study used a statistically based metamodel to determine the relative influences of design and environmental factors on acetabular cup stability by incorporating a comprehensive set of patient-dependent and surgical variables. Cup designs with 2 mm or 3 mm intended equatorial bone-implant interferences appeared to perform the best, improving implant stability with smaller mean and variability in cup relative motions and greater mean and smaller variability in ingrowth areas. Cup eccentricity was found to have no effect on implant performance. Design variables did not contribute as much to the variation in performance measures compared to the environmental variables, except for potential ingrowth areas.
引用
收藏
页数:11
相关论文
共 50 条
  • [1] Patient and surgical variability in the primary stability of cementless acetabular cups: A finite element study
    O'Rourke, Dermot
    Taylor, Mark
    JOURNAL OF ORTHOPAEDIC RESEARCH, 2020, 38 (07) : 1515 - 1522
  • [2] Primary stability of a cementless acetabular cup in a cohort of patient-specific finite element models
    O'Rourke, Dermot
    Al-Dirini, Rami M. A.
    Taylor, Mark
    JOURNAL OF ORTHOPAEDIC RESEARCH, 2018, 36 (03) : 1012 - 1023
  • [3] Finite Element Study on the Stability of Cementless Acetabular Cup
    Baharuddin, Mohd Yusof
    Kadir, Mohammed Rafiq Abdul
    6TH WORLD CONGRESS OF BIOMECHANICS (WCB 2010), PTS 1-3, 2010, 31 : 601 - +
  • [4] Initial stability of a cementless acetabular cup design: Experimental investigation on the effect of adding fins to the rim of the cup
    Baleani, M
    Fognani, R
    Toni, A
    ARTIFICIAL ORGANS, 2001, 25 (08) : 664 - 669
  • [5] Effect of cementless acetabular cup geometry on strain distribution and press-fit stability
    Ries, MD
    Harbaugh, M
    Shea, J
    Lambert, R
    JOURNAL OF ARTHROPLASTY, 1997, 12 (02) : 207 - 212
  • [6] Dependence of the primary stability of cementless acetabular cup implants on the biomechanical environment
    Raffa, Maria Letizia
    Nguyen, Vu-Hieu
    Tabor, Elisabeth
    Immel, Katharina
    Housset, Victor
    Flouzat-Lachaniette, Charles-Henri
    Haiat, Guillaume
    PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART H-JOURNAL OF ENGINEERING IN MEDICINE, 2019, 233 (12) : 1237 - 1249
  • [7] Design and development of a new acetabular cup prosthesis
    Mathias, Martin J.
    Tabeshfar, Kamran
    MATERIALS SCIENCE & ENGINEERING C-BIOMIMETIC AND SUPRAMOLECULAR SYSTEMS, 2006, 26 (08): : 1428 - 1433
  • [8] Comparison of flanged and unflanged acetabular cup design
    Orskov, Mette
    Abdulghani, Saba
    McCarthy, Ian
    Soballe, Kjeld
    Flivik, Gunnar
    ACTA ORTHOPAEDICA, 2010, 81 (05) : 556 - 562
  • [9] Comparison of the Primary Stability of a Porous Coated Acetabular Revision Cup With a Standard Cup
    Beckmann, Nicholas A.
    Jaeger, Sebastian
    Janoszka, Maciej B.
    Klotz, Matthias C.
    Bruckner, Thomas
    Bitsch, Rudi G.
    JOURNAL OF ARTHROPLASTY, 2018, 33 (02) : 580 - 585
  • [10] The effect of dorsal rim loss on the initial stability of the BioMedtrix cementless acetabular cup
    Montgomery, Meredith L.
    Kim, Stanley E.
    Dyce, Jonathan
    Pozzi, Antonio
    BMC VETERINARY RESEARCH, 2015, 11